ISO 11357-1:2016 specifies several differential scanning calorimetry (DSC) methods for the thermal analysis of polymers and polymer blends, such as
- thermoplastics (polymers, moulding compounds and other moulding materials, with or without fillers, fibres or reinforcements),
- thermosets (uncured or cured materials, with or without fillers, fibres or reinforcements), and
- elastomers (with or without fillers, fibres or reinforcements).
ISO 11357-1:2016 is intended for the observation and measurement of various properties of, and phenomena associated with, the above-mentioned materials, such as
- physical transitions (glass transition, phase transitions such as melting and crystallization, polymorphic transitions, etc.),
- chemical reactions (polymerization, crosslinking and curing of elastomers and thermosets, etc.),
- the stability to oxidation, and
- the heat capacity.
ISO 11357-1:2016 specifies a number of general aspects of differential scanning calorimetry, such as the principle and the apparatus, sampling, calibration and general aspects of the procedure and test report common to all following parts.
Details on performing specific methods are given in subsequent parts of ISO 11357 (see Foreword).

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the safety, construction and performance requirements for mechanical thermostats intended for use with gas appliances and similar use, hereafter referred to as ‘thermostats’.
This European Standard applies to thermostats with declared maximum inlet pressures up to and including 50 kPa (500 mbar) of nominal connection sizes up to and including DN 50 for use with one or more fuel gases in accordance with EN 437.
This European Standard applies to thermostats controlling the gas flow directly or indirectly through an integral gas valve, and which do not require external electrical energy for their operation.
This European Standard only applies to thermostats used with gas appliances which are not installed in the open air.
Thermostats dealt with in this European Standard are intended for control functions.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides general methods for measurement and calculation of quantities associated with human exposure to electromagnetic fields in the frequency range from 0 Hz to 300 GHz. It is intended specifically to be used for the assessment of emissions from products and comparison of these with the exposure limits for the general public given in Council Recommendation 1999/519/EC, and those given for workers in Directive 2013/35/EU, as appropriate. It also is intended to be used for assessment of human exposure to electromagnetic fields in the workplace to determine compliance with the requirements of Directive 2013/35/EU. This standard deals with quantities that can be measured or calculated external to the body, notably electric and magnetic field strength or power density, and includes the measurement and calculation of quantities inside the body that form the basis for protection guidelines. In particular the standard provides information on: — definitions and terminology, — characteristics of electromagnetic fields, — measurement of exposure quantities, — instrumentation requirements, — methods of calibration, — measurement techniques and procedures for evaluating exposure, — calculation methods for exposure assessment. Where an applicable electromagnetic field standard specific to a product or technology exists it is expected to be used rather than this document. EN 62311:—, Table 1 gives a list of relevant standards.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general requirements for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
Electrical safety requirements are not covered by this document.
Pressure safety requirements are not covered by this document.
Surface mounted temperature sensors are not covered by this document.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies initial verification tests for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
Electrical safety requirements are not covered by this document.
Pressure safety requirements are not covered by this document.
Surface mounted temperature sensors are not covered by this document.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the constructional requirements for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
Electrical safety requirements are not covered by this document.
Pressure safety requirements are not covered by this document.
Surface mounted temperature sensors are not covered by this document.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies commissioning, operational monitoring and maintenance and applies to thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
Electrical safety requirements are not covered by this document.
Pressure safety requirements are not covered by this document.
Surface mounted temperature sensors are not covered by this document.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies pattern approval tests for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
Electrical safety requirements are not covered by this document.
Pressure safety requirements are not covered by this document.
Surface mounted temperature sensors are not covered by this document.
This standard covers meters for closed systems only, where the differential pressure over the thermal load is limited.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to the constructional requirements for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.
This document is not applicable to:
-   electrical safety requirements;
-   pressure safety requirements; and
-   surface mounted temperature sensors.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies pattern approval tests for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.
This document is not applicable to:
-   electrical safety requirements;
-   pressure safety requirements; and
-   surface mounted temperature sensors.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable for the general requirements for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.
This document is not applicable to:
-   electrical safety requirements;
-   pressure safety requirements; and
-   surface mounted temperature sensors.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies initial verification tests for thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.
This document is not applicable to:
-   electrical safety requirements;
-   pressure safety requirements; and
-   surface mounted temperature sensors.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies commissioning, operational monitoring and maintenance and applies to thermal energy meters. Thermal energy meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The thermal energy meter indicates the quantity of thermal energy in legal units.
This document covers meters for closed systems only, where the differential pressure over the thermal load is limited.
This document is not applicable to:
-   electrical safety requirements;
-   pressure safety requirements; and
-   surface mounted temperature sensors.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61557-11:2009 specifies the requirements for testing equipment applied to the testing of the effectiveness of residual current monitors (RCMs) of type A and type B, which are already installed in distribution systems. This test equipment can be used in any kind of network like a TN, TT or IT system. The test equipment may also be used for testing directionally discriminating RCMs in IT-Systems.This part is to be used in conjunction with IEC 61557-1:2007, Part 1: General requirements.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61869-14:2018 provides all requirements specific to current transformers to be used in DC applications (DCCTs), whatever the technology used. The output signal can be analogue or digital. It is applicable to newly manufactured current transformers used for measuring, protection and/or control applications in DC power systems with a rated voltage above 1,5 kV. The general configuration of a single-pole low-power instrument transformer is described in Figure 601 of IEC 61869-6:2016. The DCCTs intended for current measurement in the transistor branch of the VSC valve (referred to as CT4a and CT4b in Figure 1403 and Table 1402) are not covered by this document, and will be considered in a future revision. IEC 61869-14:2018 applies to current transformers intended to be used in DC applications with at least one of the following functions: • measure DC current (with significant harmonics); • withstand DC voltage. Depending on the position on the DC system, different kinds of application exist, which are briefly described below, together with the approximate voltage or current wave shape.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61557-11:2009 specifies the requirements for testing equipment applied to the testing of the effectiveness of residual current monitors (RCMs) of type A and type B, which are already installed in distribution systems. This test equipment can be used in any kind of network like a TN, TT or IT system. The test equipment may also be used for testing directionally discriminating RCMs in IT-Systems.This part is to be used in conjunction with IEC 61557-1:2007, Part 1: General requirements.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the requirements, in addition to the resistance versus
temperature relationship, for both industrial platinum resistance thermometers (later referred to
as "thermometers") and industrial platinum resistance temperature sensors (later referred to as
"platinum resistors") whose electrical resistance is derived from defined functions of
temperature.
Values of temperature in this document are in terms of the International Temperature Scale of
1990, ITS-90. A temperature in the unit °C of this scale is denoted by the symbol t, except in
Table A.1 where the full nomenclature t90 /°C is used.
This document applies to platinum resistors whose temperature coefficient α, defined as
is conventionally written as α = 3,851⋅10-3 °C-1, where R100 is the resistance at t = 100 °C and R0 is the resistance at t = 0 °C.
This document covers platinum resistors and thermometers for the temperature range −200 °C
to +850 °C with different tolerance classes. It can also cover particular platinum resistors or
thermometers for a part of this temperature range.
For resistance versus temperature relationships with uncertainties less than 0,1 °C, which are
possible only for platinum resistors or thermometers with exceptionally high stability and
individual calibration, a more complex interpolation equation than is presented in this document
can be necessary. The specification of such equations is outside the scope of this document.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies two methods (isothermal and non-isothermal) for studying the crystallization
kinetics of partially crystalline polymers using differential scanning calorimetry (DSC).
It is only applicable to molten polymers.
NOTE These methods are not suitable if the molecular structure of the polymer is modified during the test.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61557 specifies the requirements applicable to measuring equipment for
testing the effectiveness of protective measures of residual current devices (RCD) installed in
TT, TN and IT systems.
It is not the purpose of this document to verify the RCD according to their product standards.
NOTE Applicable tripping tests for time and current of RCD are listed in Annex A, Table A.1

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the requirements, in addition to the resistance versus temperature relationship, for both industrial platinum resistance thermometers (later referred to as "thermometers") and industrial platinum resistance temperature sensors (later referred to as "platinum resistors") whose electrical resistance is derived from defined functions of temperature. Values of temperature in this document are in terms of the International Temperature Scale of 1990, ITS-90. A temperature in the unit °C of this scale is denoted by the symbol t, except in Table A.1 where the full nomenclature t90 /°C is used. This document applies to platinum resistors whose temperature coefficient α, defined as α= R100 − R0 R0 ⋅ 100°C is conventionally written as α = 3,851⋅10-3 °C-1, where R100 is the resistance at t = 100 °C and R0 is the resistance at t = 0 °C. This document covers platinum resistors and thermometers for the temperature range −200 °C to +850 °C with different tolerance classes. It can also cover particular platinum resistors or thermometers for a part of this temperature range. For resistance versus temperature relationships with uncertainties less than 0,1 °C, which are possible only for platinum resistors or thermometers with exceptionally high stability and individual calibration, a more complex interpolation equation than is presented in this document can be necessary. The specification of such equations is outside the scope of this document.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61557-6:2019 is available as IEC 61557-6:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61557-6:2019 specifies the requirements applicable to measuring equipment for testing the effectiveness of protective measures of residual current devices (RCD) installed in TT, TN and IT systems. It is not the purpose of this document to verify the RCD according to their product standards. IEC 61557-6:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of requirements for testing a new type of RCD; b) addition of requirements for type B RCDs (former Annex B); c) addition of new Annex B on recommended tripping times; d) alignment of the structure with that of the whole IEC 61557 series.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61757 specifies the terminology, characteristic performance parameters and
related test methods of optical temperature sensors based on fibre Bragg gratings (FBG) that
carry out temperature measurements in the temperature range between –260 °C and 600 °C.
Generic specifications for fibre optic sensors are defined in IEC 61757.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

It is necessary for thermocouple temperature measurement that the electro-motive force (abbreviated
as e.m.f. hereafter) of the thermocouple circuit is precisely measured by a measuring
instrument. A thermocouple is electrically connected to the instrument by a proper pair of
electric cables. IEC 60584-3 standardizes these cables. It specifies identification and manufacturing
tolerances for extension and compensating cables (mineral insulated extension and
compensating cables are not included) provided directly to users of industrial processes.
These tolerances are determined with respect to the e.m.f. versus temperature relationship of
IEC 60584-1. The requirements for extension and compensating cables for use in industrial
process control are specified.
Extension and compensating cables may consist of a single strand (solid) wire or multistranded
wire for which this document is applied. Specification for extension and compensating
conductors of forms of rods, flat wires or strips can be established by agreement between
suppliers and users.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62828-3:2018 establishes specific procedures for testing temperature transmitters used in measuring and control systems for industrial process and for machinery control systems. When the process measurement transmitter features the temperature transmitter separated from the sensing element, the standard applies only to the temperature transmitter without the sensing element. In the case of a device where the sensing element is fully integrated with the temperature transmitter, the standard applies to the complete device. For general test procedures, reference is made to IEC 62828-1, which is applicable to all types of industrial and process measurement transmitters (PMT). The sensing element itself as well as radiation thermometers are excluded from the scope of this document. The IEC 62828 series cancels and replaces the IEC 60770 series and proposes revisions for the IEC 61298 series. NOTE In industrial and process applications to indicate the process measurement transmitters, it is common also to use the terms “industrial transmitters”, or “process transmitters”.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

European standard establishes the procedures and methodology on measurement and calculation of quantities associated with the assessment of human exposure to electric, magnetic and electromagnetic fields in the frequency range from 0 Hz to 300 GHz. It deals with quantities that can be measured or calculated in free space, notably electric and magnetic field strength and includes the measurement and calculation of quantities inside the body that forms the basis for protection guidelines.
In particular the standard provides information on
− definitions and terminology,
− characteristics of electric, magnetic and electromagnetic fields,
− measurement of exposure quantities,
− instrumentation requirements,
− methods of calibration,
− measurement techniques and procedures for evaluating exposure,
− calculation methods for exposure assessment.
The object of this standard is to establish a common reference for the assessment of electrical equipment in relation to human exposure from non-ionising electromagnetic fields.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60584-3:2021 It is necessary for thermocouple temperature measurement that the electro-motive force (abbreviated as e.m.f. hereafter) of the thermocouple circuit is precisely measured by a measuring instrument. A thermocouple is electrically connected to the instrument by a proper pair of electric cables. IEC 60584-3:2021 standardizes these cables. It specifies identification and manufacturing tolerances for extension and compensating cables (mineral insulated extension and compensating cables are not included) provided directly to users of industrial processes. These tolerances are determined with respect to the e.m.f. ver-sus temperature relationship of IEC 60584-1. The requirements for extension and compensating cables for use in industrial process control are specified.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for determining the specific heat capacity of plastics by differential
scanning calorimetry.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The EN 1434 standard provides technical principles and practical advice in selecting, installing and commissioning of thermal energy meters. However, because a standard cannot cover all areas completely, this document assists users of thermal energy meters.

  • Technical report
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60584-3:2021 It is necessary for thermocouple temperature measurement that the electro-motive force (abbreviated as e.m.f. hereafter) of the thermocouple circuit is precisely measured by a measuring instrument. A thermocouple is electrically connected to the instrument by a proper pair of electric cables. IEC 60584-3:2021 standardizes these cables. It specifies identification and manufacturing tolerances for extension and compensating cables (mineral insulated extension and compensating cables are not included) provided directly to users of industrial processes. These tolerances are determined with respect to the e.m.f. ver-sus temperature relationship of IEC 60584-1. The requirements for extension and compensating cables for use in industrial process control are specified.

  • Standard
    23 pages
    English and French language
    sale 15% off

IEC 60172:2020  which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. NOTE The data obtained according to this test procedure provide the designer and development engineer with information for the selection of winding wire for further evaluation of insulation systems and equipment tests. This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision of 3.1, definition of thermal index;
- revision of 3.3, time to failure;
- revisions to 5.1.1 for clarity and to reduce the range wire size range to which the test applies;
- revisions to 5.1.2 for tape wrapped round and enamelled or tape wrapped rectangular wire for clarity;
- revision to Clause 9 to add the correlation coefficient, r to the report.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The EN 1434 standards provides technical principles and practical advice in selecting, installing and commissioning of thermal energy meters. However, because a standard cannot cover all areas completely, this document assists users of thermal energy meters.

  • Technical report
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62828-4:2020 establishes specific procedures for testing level transmitters used in measuring and control systems for industrial process and machinery control systems. For general test procedures, reference is to be made to IEC 62828-1:2017, applicable to all types of transmitters. Throughout this document, the term "industrial transmitters" covers all types of transmitters used in measuring and control systems for industrial processes and for machinery. The requirements of this document are applicable to all level measurement principles. Detailed description of transmitters is given for two main principles for improved clarity.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62828-5:2020 establishes specific procedures for testing flow transmitters used in measuring and control systems for industrial process and for machinery control systems. For general test procedures, reference is to be made to IEC 62828-1:2017, applicable to all types of industrial and process measurement transmitters. This document – together with IEC 62828-1:2017 – is the reference standard for testing every type of flow transmitter, not only for liquids but also for gases and for steam. In this document, "industrial flow transmitters" consistently covers all types of flow transmitters used in measuring and control systems for industrial process and for machinery.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62828-5:2020 establishes specific procedures for testing flow transmitters used in measuring and control systems for industrial process and for machinery control systems. For general test procedures, reference is to be made to IEC 62828-1:2017, applicable to all types of industrial and process measurement transmitters.
This document – together with IEC 62828-1:2017 – is the reference standard for testing every type of flow transmitter, not only for liquids but also for gases and for steam.
In this document, "industrial flow transmitters" consistently covers all types of flow transmitters used in measuring and control systems for industrial process and for machinery.

  • Standard
    70 pages
    English and French language
    sale 15% off

IEC 62828-4:2020 establishes specific procedures for testing level transmitters used in measuring and control systems for industrial process and machinery control systems. For general test procedures, reference is to be made to IEC 62828-1:2017, applicable to all types of transmitters.
Throughout this document, the term "industrial transmitters" covers all types of transmitters used in measuring and control systems for industrial processes and for machinery.
The requirements of this document are applicable to all level measurement principles.
Detailed description of transmitters is given for two main principles for improved clarity.

  • Standard
    116 pages
    English and French language
    sale 15% off

ISO 80601-2-56:2017 applies to the basic safety and essential performance of a clinical thermometer in combination with its accessories, hereafter referred to as me equipment. This document specifies the general and technical requirements for electrical clinical thermometers. This document applies to all electrical clinical thermometers that are used for measuring the body temperature of patients.
Clinical thermometers can be equipped with interfaces to accommodate secondary indicators, printing equipment, and other auxiliary equipment to create me systems. This document does not apply to auxiliary equipment.
Me equipment that measures a body temperature is inside the scope of this document.
ISO 80601-2-56:2017 does not specify the requirements for screening thermographs intended to be used for the individual non-invasive human febrile temperature screening of groups of individual humans under indoor environmental conditions, which are given in IEC 80601‑2‑59[4].
If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant.
Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005+A1:2012, 7.2.13 and 8.4.1.
NOTE          Additional information can be found in IEC 60601?1:2005+A1:2012, 4.2.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The object of this document is to determine the composition, nature of materials, manufacturing tests and thermoelectronic behaviour of connectors for sensors using thermocouples according to EN 60584-3:2008.This document does not cover such special thermocouples as U, L and W types; nevertheless, the user of such special thermocouples can use the connectors described hereafter with some restrictions mentioned in the relevant paragraphs.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61788-4 specifies a test method for the determination of the residual resistanceratio (RRR) of Nb-Ti and Nb3Sn composite superconductors with Cu, Cu-Ni, Cu/Cu-Ni and Almatrix in a strain-free condition and zero external magnetic field. This method is intended foruse with superconductor specimens that have a monolithic structure with rectangular or roundcross-section, RRR value less than 350, and cross-sectional area less than 3 mm2. In the caseof Nb3Sn, the specimens have received a reaction heat-treatment.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61788-4:2020 is available as IEC 61788-4:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61788-4:2020 specifies a test method for the determination of the residual resistance ratio (RRR) of Nb-Ti and Nb3Sn composite superconductors with Cu, Cu-Ni, Cu/Cu-Ni and Al matrix in a strain-free condition and zero external magnetic field. This method is intended for use with superconductor specimens that have a monolithic structure with rectangular or round cross-section, RRR value less than 350, and cross-sectional area less than 3 mm2. In the case of Nb3Sn, the specimens have received a reaction heat-treatment. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) change in the suitable distance of voltage taps on the specimen for reliable measurement, b) new report on the result of the round robin test of the residual resistance ratio of Nb3Sn superconductors that proves the validity of the measurement method in this standard, c) revision of the confusing definitions of the copper ratio and copper fraction.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-06-05-JO- BT N 11989 to delink EN ISO 80601-2-56:2017/prA1 from MDD and M/023
2019-03-07-JO - Awaiting for TC to resolve the negative assessment of the HAS consultant at ENQ stages. FV dispactch was due  on the 18th of January 2019.
DOW = DAV + 36 months

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives names, symbols, definitions and units for quantities of thermodynamics. Where appropriate, conversion factors are also given.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63144-1:2020(E) applies, in the field of metrology, to the statement and testing of technical data in datasheets and instruction manuals for thermographic cameras that are used to measure the temperature of surfaces. This includes, unless otherwise stated, both two-dimensional and one-dimensional (line cameras or line scanners) temperature measuring instruments, independently of the scanning principle (fixed multi-element detector or scanning camera system).
This document describes standard test methods to determine relevant metrological data of thermographic cameras. Manufacturers and sellers can choose relevant data and can state that the data shall be compliant with this Technical Specification.

  • Technical specification
    44 pages
    English language
    sale 15% off

EN-ISO 11357-2 specifies methods for the determination of the glass transition temperature and the step height related to the glass transition of amorphous and partially crystalline plastics.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61340-4-7:2017 provides test methods and procedures for evaluating and selecting air ionization equipment and systems (ionizers). This document establishes measurement techniques, under specified conditions, to determine offset voltage (ion balance) and decay (charge neutralization) time for ionizers. This document does not include measurements of electromagnetic interference (EMI), or the use of ionizers in connection with ordnance, flammables, explosive items or electrically initiated explosive devices. As contained in this document, the test methods and test conditions can be used by manufacturers of ionizers to provide performance data describing their products. Users of ionizers are urged to modify the test methods and test conditions for their specific application in order to qualify ionizers for use, or to make periodic verifications of ionizer performance. The user will decide the extent of the data required for each application. This edition includes the following significant technical changes with respect to the previous edition: - the use of contacting plate voltage measurements in addition to the previous non-contacting plate voltage measurements has been added. Charged plate monitors (CPMs) using this technology have been in use in the industry for many years.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to activities that: manufacture, process, assemble, install, package, label, service, test, inspect, transport or otherwise handle electrical or electronic parts, assemblies and equipment susceptible to damage by electrostatic discharges greater than or equal to 100 V human body model (HBM). Provides the requirements for an ESD control program. The user should refer to IEC 61340-5-2 for guidance on the implementation of this standard. Does not apply to electrically initiated explosive devices, flammable liquids, gases and powders. The purpose of this standard is to provide the administrative and technical requirements for establishing, implementing and maintaining an ESD control program (hereinafter referred to as the 'program'). The main changes with respect to the previous edition are listed below: This version of IEC 61340-5-1 focuses on the requirements for an ESD control program. In addition, this version of IEC 61340-5-1 has been aligned with other major ESD control program standards used throughout the world.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives names, symbols, definitions and units for quantities of thermodynamics. Where
appropriate, conversion factors are also given.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61340-4-9:2016 provides test methods for evaluating the electrical resistance of garments that contain surface conductive or dissipative components or materials used in the electronics industry for the control of electrostatic discharge. This standard defines procedures for measuring electrical resistance, including a system resistance test for garments that provide a ground path for personnel. This edition includes the following significant technical changes with respect to the previous edition: a) classification of three types of garments - static control garments, - groundable static control garments, and - groundable static control garment system; b) additional measurements according to the the garment type including cuff measurements, panel to groundable point, testing with a person in the garment system; c) sleeve to sleeve measurements allowed with probes or by hanging; d) additional recommended values for new garment types as set out in Annex A.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60909-0:2016 is applicable to the calculation of short-circuit currents in low-voltage three-phase AC systems, and in high-voltage three-phase AC systems, operating at a nominal frequency of 50 Hz or 60 Hz. It establishes a general, practicable and concise procedure leading to results which are generally of acceptable accuracy and deals with the calculation of short-circuit currents in the case of balanced or unbalanced short circuits. This second edition cancels and replaces the first edition published in 2001. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - contribution of windpower station units to the short-circuit current; - contribution of power station units with ful size converters to the short-circuit current; - new document structure.

  • Standard
    76 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61515:2016 establishes the requirements for simplex, duplex and triplex mineral-insulated metal-sheathed thermocouple cables and thermocouples, which are intended for use in general industrial applications. The abbreviation MIMS (for "mineral-insulated metal-sheathed") will be used hereafter. It covers thermocouple cables and thermocouples with only base-metal conductors of Types T, J, E, K and N. The specifications in this standard apply to new thermocouple cables and thermocouple units as delivered to the user. They do not apply to the product after use. This second edition cancels and replaces the first edition published in 1995. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Duplex and triplex are standardized. - Specification of insulation resistance is revised so that the user can choose the best product to fit for the purpose. - "Table 2 Recommended maximum operating temperatures" in the previous version is expanded significantly including newly developed sheath material and it is moved to Annex C. - Test items and their methods are expanded and a guide table (Table 4) is added for userfriendliness.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day