This document specifies dimensions of neck finishes for aerosol and spray glass containers, in order to guarantee tight sealing of valves or pumps with ferrules defined by EN 14849.
It applies to glass containers with a nominal diameter of the neck finish around 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm for both moulded and tubular glass neck finishes.
NOTE   These neck finishes are commonly called FEA 11, 13, 15, 17, 18 and 20.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the critical dimensions of the neck finish of glass aerosol containers with respect to the thorough and tight closing of valves with ferrules defined in EN 14849.
This standard is applicable to a nominal diameter of 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm necked aerosol containers with moulded and tubular neck finishes.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the relationship between the nominal volume of product and the maximum nominal brimful capacity of the outer container of the compartmented aerosol dispenser.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the relationship between the nominal volume of product and the maximum nominal brimful capacity of the outer container of the compartmented aerosol container.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the critical dimensions of valve cups suitable for clinching into 25,4 mm aperture metal aerosol containers.
This document is applicable to aperture metal aerosol containers which are used with the metal aerosol containers in accordance with EN 14847 and EN 15006.
This European Standard does not specify dimples on aperture metal aerosol containers.
NOTE   To provide satisfactory filling in production, dimples are no longer considered essential but might still be used. Their presence could cause damage of the 25,4 mm aperture and their presence on lacquered cups can give rise to coating defects at the dimple feature. Thus, in the interest of simplicity and reduction of difficulties, dimples are excluded from this standard.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the critical dimensions of valve cups suitable for clinching into 25,4 mm aperture metal aerosol containers. This document is applicable to aperture metal aerosol containers which are used with the metal aerosol containers in accordance with EN 14847 and EN 15006. This European Standard does not specify dimples on aperture metal aerosol containers.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the dimensions of two and three-piece tinplate aerosol containers with nominal brimful capacities.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the dimensions and volumes for one-piece aluminium aerosol containers with a 25,4 mm aperture.
This European Standard applies to one-piece containers of monobloc construction with an ogival, spherical or flat shoulder.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the dimensions of two and three-piece tinplate aerosol containers with nominal brimful capacities in accordance with European Directive 80/232/EEC [2].

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TThis European Standard specifies the dimensions and volumes for one-piece aluminium aerosol containers with a 25,4 mm aperture in relation to the capacities fixed by European Directive 80/232/EEC [2].
This standard applies to one-piece containers of monobloc construction with an ogival, spherical or flat shoulder.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the following dimensions of aluminium metal aerosol cans with 25,4 mm aperture: contact height, outside diameter, inside diameter and shoulder height. It is intended to be used with EN 14848 for clinching with valve cups.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the critical dimensions of the location of the 25,4 mm aperture relative to the base of aerosol cans for clinching with valve cups.
The specification of the fundamental dimensions in this standard, relates to all 25,4 mm aperture aluminium and aluminium alloy cans, irrespective of size, shape and mode of manufacture; whose dimensions and tolerances fall within the dimensional scope of EN 15008.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the following dimensions of aluminium metal aerosol cans with 25,4 mm aperture: contact height, outside diameter, inside diameter and shoulder height. It is intended to be used with EN 14848 for clinching with valve cups.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the critical dimensions of the location of the 25,4 mm aperture relative to the base of aerosol cans for clinching with valve cups.
The specification of the fundamental dimensions in this standard, relates to all 25,4 mm aperture aluminium and aluminium alloy cans, irrespective of size, shape and mode of manufacture; whose dimensions and tolerances fall within the dimensional scope of EN 15008.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the following dimensions of tinplate metal aerosol cans with 25,4 mm aperture: contact height, outside diameter, inside diameter and shoulder height. It is intended to be used with EN 14848 for clinching with valve cups.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a method of measuring the contact height of the compression closure between the valve cup and the aperture of an aerosol container.
This standard applies to aerosol containers with 25,4 mm apertures as specified in EN 14847 and prEN 15006 fitted with aerosol valve cups as specified in EN 14848.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the dimensions which are important for an effective fastening of valves on glass aerosol containers with a nominal diameter of 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm neck finish, as defined in EN 14854.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the dimensions which are important for an effective fastening of valves on glass aerosol containers with a nominal diameter of 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm neck finish, as defined in EN 14854.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a method of measuring the contact height of the compression closure between the valve cup and the aperture of an aerosol container.
This standard applies to aerosol containers with 25,4 mm apertures as specified in EN 14847 and prEN 15006 fitted with aerosol valve cups as specified in EN 14848.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the following dimensions of tinplate metal aerosol cans with 25,4 mm aperture: contact height, outside diameter, inside diameter and shoulder height. It is intended to be used with EN 14848 for clinching with valve cups.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

This European Standard specifies the critical dimensions of the neck finish of glass aerosol containers with respect to the thorough and tight closing of valves with ferrules defined in EN 14849.
This standard is applicable to a nominal diameter of 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm necked aerosol containers with moulded and tubular neck finishes.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the critical dimensions of the neck finish of glass aerosol containers with respect to the thorough and tight closing of valves with ferrules defined in EN 14849.
This standard is applicable to a nominal diameter of 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm necked aerosol containers with moulded and tubular neck finishes.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the relationship between the nominal volume of product and the maximum nominal brimful capacity of the outer container of the compartmented aerosol container.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the relationship between the nominal volume of product and the maximum nominal brimful capacity of the outer container of the compartmented aerosol container.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Popravek k standardu SIST EN 14848:2006
This European Standard specifies the critical dimensions of valve cups suitable for clinching into 25,4 mm aperture metal aerosol containers. This standard is intended to be used with the metal aerosol containers specified in EN 14847 and prEN 15006.

  • Corrigendum
    2 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the critical dimensions of valve cups suitable for clinching into 25,4 mm aperture metal aerosol containers.
This standard is intended to be used with the metal aerosol containers specified in EN 14847 and prEN 15006.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TC/CMC - Corrections in the key of Figure 1 and heading row of Table 1 - text inserted byt Ted, sent to confirmation by TC and not checked carefully by TC in E version, as a result, the F + D version translated wrong wording

  • Corrigendum
    2 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the critical dimensions of valve cups suitable for clinching into 25,4 mm aperture metal aerosol containers.
This standard is intended to be used with the metal aerosol containers specified in EN 14847 and prEN 15006.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the dimensions of two and three-piece tinplate aerosol containers with nominal brimful capacities in accordance with European Directive 80/232/EEC [2].

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TThis European Standard specifies the dimensions and volumes for one-piece aluminium aerosol containers with a 25,4 mm aperture in relation to the capacities fixed by European Directive 80/232/EEC [2].
This standard applies to one-piece containers of monobloc construction with an ogival, spherical or flat shoulder.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TThis European Standard specifies the dimensions and volumes for one-piece aluminium aerosol containers with a 25,4 mm aperture in relation to the capacities fixed by European Directive 80/232/EEC [2].
This standard applies to one-piece containers of monobloc construction with an ogival, spherical or flat shoulder.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the dimensions of two and three-piece tinplate aerosol containers with nominal brimful capacities in accordance with European Directive 80/232/EEC [2].

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard  describes the method of  determining the flammability of an  aerosol product sprayed in the  form of a foam, mousse, gel or  paste. 2 Terms and definitions  For the purposes of this  document, the following terms  and definitions apply. 2.1 ignition  appearance of a stable flame  which is at least 4 cm high and  which is maintained for at least 2  s. 3 Principle Approximately 5 g  of foam, mousse gel or paste is  sprayed from the aerosol  container on to a watchglass. An  ignition source (candle, wax  taper, match or lighter) is placed  at the base of the watchglass  and any ignition and sustained  combustion of the foam, mousse,  gel or paste is observed. 4  Apparatus 4.1 Scale for  measuring height of flame,  graduated in centimetres. 4.2  Support and clamp for holding the  graduated scale in position. 4.3  Fire-resistant watchglass,  approximately 150 mm in  diameter. 4.4 Chronometer  (stopwatch), accurate to ˝ 0, 2 s.  4.5 Candle, wax taper, match or  lighter. 4.6 Calibrated laboratory  scales (balance), accurate to ˝ 0,  1 g. 4.7 Water bath, accurate to ˝  1 °C and maintained at 20 °C. 4.8  Thermometer, accurate to ˝ 1 °C.  4.9 Hygrometer, accurate to ˝ 5  %. 4.10 Pressure gauge,  accurate to ˝ 0, 1 bar. 5  Preparation of test apparatus 5.1  Place the watchglass on a fire- resistant surface within a  draught-free area that can be  ventilated after each test. 5.2  Position the graduated scale  exactly behind the watchglass so  that the origin of the scale is level  with the watchglass base in a  horizontal plane. 5.3 Restrain the  scale vertically in this position by  means of the support and clamp.  5.4 Condition a minimum of four  full aerosol dispensers per  product to 20 °C ˝ 1 °C by  immersing at least 95 % of the  dispenser in water at this  temperature for at least 30 min  before each test. 6 Test  conditions The tests shall be  carried out in a draught-free  environment capable of  ventilation, with the temperature  controlled at 20 °C ˝ 5 °C and  relative humidity in the range of  30 % to 80 %. 7 Test procedure  7.1 Prime each aerosol dispenser  by discharging for approximately  1 s. NOTE The purpose of this  action is to remove non- homogeneous material from the  diptube. 7.2 Record the  temperature and relative humidity  of the environment. 7.3 Determine  the internal pressure within the  aerosol dispenser at 20 °C ˝ 1 °C.  If the internal pressure indicates  that the dispenser is likely to be  faulty or incompletely filled it  shall not be used for the test. 7.4  Measure the discharge rate or  flow rate of the aerosol product to  be examined, so that the amount  of test product dispensed can be  more accurately gauged. 7.5  Determine the total mass of the  full aerosol dispenser. 7.6 On the  basis of the measured discharge  or flow rate, and following the  manufacturer's instructions,  release approximately 5 g of the  product onto the centre of the  clean watchglass with the aim of  producing a mound no higher  than 25 mm. Follow strictly the  manufacturer's instructions for  use, including whether the  dispenser is intended to be used  in the upright or inverted position.  When shaking is required, shake  immediately before testing. 7.7  Within 5 s of completion of  discharge, apply the source of  ignition to the edge of the sample  at its base and at the same time  start the chronometer  (stopwatch). If necessary, remove  the ignition source from the edge  of the sample after a few seconds  in order to clearly observe if  ignition has occurred.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method of determining the flammability of a product emerging from an aerosol dispenser in an enclosed or confined space.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a method of determining the maximum distance between the orifice of an aerosol container and a flame that results in ignition and sustained combustion of an aerosol spray. The standard applies to aerosol products that have a spray distance of 150 mm or more. It does not apply to aerosol containers fitted with a metering valve.
NOTE   Aerosol products dispensed in the form of a foam, mousse, gel or paste which have a spray distance of less than 150 mm are specified in EN 14851.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes the method of determining the flammability of an aerosol product sprayed in the form of a foam, mousse, gel or paste.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a method of determining the maximum distance between the orifice of an aerosol container and a flame that results in ignition and sustained combustion of an aerosol spray. The standard applies to aerosol products that have a spray distance of 150 mm or more. It does not apply to aerosol containers fitted with a metering valve.
NOTE   Aerosol products dispensed in the form of a foam, mousse, gel or paste which have a spray distance of less than 150 mm are specified in EN 14851.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method of determining the flammability of a product emerging from an aerosol dispenser in an enclosed or confined space.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies material, construction, inspection and marking requirements for non-refillable metallic gas cartridges with or without a valve for use with portable appliances which comply with the requirements of EN 521 "Portable appliances operating at vapour pressure from liquiefied petroleum gas containers". 1).

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off

Specifies dimensions of cans with nominal internal body diameters ranging from 45 mm up to 65 mm. Figure 1 illustrates the shape.

  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off