This European standard specifies general requirements, minimum performance requirements and test procedures for open channelinstrumentation used to determine either volumetric flow-rate and/or total volume passed of waters in artificial open channels. Itcovers the following technology categories:
−Level sensors with associated electronics designed to be used with a conventional gauging structure (e.g. weir or flumefor which the stage discharge characteristics are established and published in a national or international standard) or afluid velocity sensor.
−Integrated velocity area devices comprising level and velocity sensors that may be separate or combined in a single assembly;
−Velocity sensors that determine the mean water velocity through a channel.
It is recognised that for some OCIs certain tests cannot be carried out.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements, minimum performance requirements and test procedures for open channel instrumentation used to determine either volumetric flow-rate and/or total volume passed of waters in artificial open channels. It covers the following technology categories:
- Level sensors with associated electronics designed to be used with a conventional gauging structure. (The requirements and test procedures for gauging structures, such as weirs and flumes, are excluded. The stage discharge characteristics for many of these structures are established and published in national and international standards).
- Water velocity sensors.
- Integrated velocity area instruments comprising level and velocity sensors that may be separate or combined in a single assembly.
- Velocity sensors that determine the mean water velocity through a channel.
It is recognized that for some OCIs, certain tests cannot be carried out.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements, minimum performance requirements and test procedures for instrumentation used to measure either volumetric flow-rate and/or total volume passed of water in closed conduits. It covers all closed conduit instrument (CCI) technologies intended to operate in closed pressurized pipes and partially filled pipes. Requirements are expressed in volumetric units which may be converted to mass using the density of the water.
It is recognized that for some CCIs certain tests cannot be carried out.
The data obtained from the testing of CCIs in accordance with the requirements of the Measuring Instruments Directive [1] or EN ISO 4064-1 [2] can be used to meet, in part, the requirements specified in this document. However, for the avoidance of doubt, compliance with the requirements of this document does not equate to compliance with the requirements of the Measuring Instruments Directive or EN ISO 4064-1.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides an understanding of the nature of measurement uncertainty and its significance in estimating the "quality" of a measurement or a determination in hydrometry.
This document is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

  • Standard
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides an understanding of the nature of measurement uncertainty and its significance in estimating the "quality" of a measurement or a determination in hydrometry.
This document is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

  • Standard
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for the measurement of flow in rivers and artificial channels under steady or slowly varying flow conditions, using certain types of critical-depth flumes (also known as “standing-wave flumes”). A wide variety of flumes has been developed, but only those critical-depth flumes which have received general acceptance after adequate research and field testing, and which therefore do not require in situ calibration, are considered herein. The flow conditions considered are uniquely dependent on the upstream head, i.e. subcritical flow must exist upstream of the flume, after which the flow accelerates through the contraction and passes through its critical depth (see Figure 1). The water level downstream of the structure is low enough to have no influence upon its performance. This document is applicable to three commonly used types of flumes, covering a wide range of applications, namely rectangular-throated, trapezoidal-throated and U-throated. The hydraulic theory behind this document was presented in Reference [7]. This document is not applicable to a form of flume referred to in the literature (sometimes called a “Venturi” flume) in which the flow remains subcritical throughout. NOTE The Venturi form of flume is based on the same principle as a Venturi meter used within a closed conduit system and relies upon gauging the head at two locations and the application of Bernoulli’s energy formula.

  • Standard
    79 pages
    English language
    sale 15% off
  • Standard
    80 pages
    French language
    sale 15% off

This document specifies the functional requirements of instrumentation for measuring the level of water surface (stage), primarily for the purpose of determining flow rates.
This document is supplemented by Annex A, which provides guidance on the types of automatic water level measurement devices currently available and the measurement uncertainty associated with them. The manually operated measuring devices are described in Annex B.
This document is applicable to both contact and non-contact methods of measurement. The non-contact methods are not in direct material contact with the water surface but measure the height of the water level with ultrasonic or electromagnetic waves.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terms and symbols used in standards in the field of hydrometry.

  • Standard
    92 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    83 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-3:2019 is available as IEC 60704-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60704-3:2019 describes procedures for determining and verifying the declared values of the noise emitted by household and similar appliances. It applies to all categories of household and similar electrical appliances covered by IEC 60704-1 and all parts of IEC 60704-2, which include particular requirements for special categories of appliances. It applies to appliances being produced in quantity, such as in batches, series or lots, which are manufactured to the same technical specification and characterized by the same declared value of noise emission. This part of IEC 60704: – considers the term "declaration" to include all means for providing information on the noise emission values to potential users (consumers) of the appliances; this includes labels, brochures, advertisements, commercial and technical information papers, etc.; – considers the declaration for appliances manufactured by mass production; – specifies a simple statistical method for verifying the declared values by investigating a sample of only three appliances. This International Standard is to be used in conjunction with IEC 60704-1:2010 and the latest edition of IEC 60704-2 (all parts). This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition: a) in Annex A, standard deviations that are now specified for various appliance categories in the parts of IEC 60704-2 have been excluded from Table A.1; b) furthermore, this edition makes reference to new standards and is implementing ISO/IEC Directives, Part 2 in a more accurate manner.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for determining the velocity and cross-sectional area of water flowing in open channels and for calculating the discharge employing point velocity measurement devices.
It is applicable to methods using rotating-element current meters, acoustic doppler velocimeters (ADVs), acoustic doppler current profiler (ADCP) stationary method, surface velocity measurement including floats and other surface velocity systems.
Although some general procedures are discussed, this document does not describe in detail how to use or deploy these systems.
NOTE         For detailed procedures, refer to guidelines from instrument manufacturers and the appropriate public agencies.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the functional requirements of instrumentation for measuring the level of
water surface (stage), primarily for the purpose of determining flow rates.
This document is supplemented by Annex A, which provides guidance on the types of automatic water
level measurement devices currently available and the measurement uncertainty associated with them.
The manually operated measuring devices are described in Annex B.
This document is applicable to both contact and non-contact methods of measurement. The non-contact
methods are not in direct material contact with the water surface but measure the height of the water
level with ultrasonic or electromagnetic waves.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the functional requirements of instrumentation for measuring the level of water surface (stage), primarily for the purpose of determining flow rates. This document is supplemented by Annex A, which provides guidance on the types of automatic water level measurement devices currently available and the measurement uncertainty associated with them. The manually operated measuring devices are described in Annex B. This document is applicable to both contact and non-contact methods of measurement. The non-contact methods are not in direct material contact with the water surface but measure the height of the water level with ultrasonic or electromagnetic waves.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    29 pages
    French language
    sale 15% off
  • Draft
    28 pages
    English language
    sale 15% off

This document defines terms and symbols used in standards in the field of hydrometry

  • Standard
    92 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    83 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terms and symbols used in standards in the field of hydrometry.

  • Standard
    84 pages
    English language
    sale 15% off
  • Standard
    86 pages
    French language
    sale 15% off
  • Draft
    6 pages
    English language
    sale 15% off

This document specifies methods for determining the velocity and cross-sectional area of water flowing
in open channels and for calculating the discharge employing point velocity measurement devices.
It is applicable to methods using rotating-element current meters, acoustic doppler velocimeters (ADVs),
acoustic doppler current profiler (ADCP) stationary method, surface velocity measurement including
floats and other surface velocity systems.
Although some general procedures are discussed, this document does not describe in detail how to use
or deploy these systems.
NOTE For detailed procedures, refer to guidelines from instrument manufacturers and the appropriate
public agencies.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for determining the velocity and cross-sectional area of water flowing in open channels and for calculating the discharge employing point velocity measurement devices. It is applicable to methods using rotating-element current meters, acoustic doppler velocimeters (ADVs), acoustic doppler current profiler (ADCP) stationary method, surface velocity measurement including floats and other surface velocity systems. Although some general procedures are discussed, this document does not describe in detail how to use or deploy these systems. NOTE For detailed procedures, refer to guidelines from instrument manufacturers and the appropriate public agencies.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    44 pages
    French language
    sale 15% off
  • Draft
    43 pages
    English language
    sale 15% off
  • Draft
    44 pages
    French language
    sale 15% off

This document specifies the functional requirements and characteristics of the different types of suspended-sediment samplers used for collecting water-sediment mixtures from streams, rivers, lakes and reservoirs. This document does not include equipment for collecting samples in closed conduits and wastewater discharges. NOTE The units of measurement used in this document are SI units.

  • Standard
    13 pages
    English language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 15% off

This document specifies the typical requirements of instrumentation for measuring liquid precipitation, primarily for the purpose of hydrological and meteorological observation. This document is applicable to both non-recording and recording catching-type precipitation gauges for the measurement of liquid precipitation. This document covers design criteria for the gauges and elements to be considered in their construction. This document does not include specification, design and installation conditions. NOTE Since the measurement of solid precipitation is outside the scope, the disadvantages of solid precipitation apply to all gauges listed in Annex A. The measurement of solid precipitation and associated disadvantages are well documented in Reference [1].

  • Standard
    18 pages
    English language
    sale 15% off
  • Draft
    21 pages
    English language
    sale 15% off

This document specifies a calibration method for mechanical type, electromagnetic type and acoustic type hydrometric current-meters used for point velocity measurement of flowing water. The method requires towing the instrument through still water in a straight open tank. It includes measuring apparatus, the calibration procedure, the method of presenting the results and the uncertainties associated with the method.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 15% off

This document gives guidelines for the use of boat-mounted acoustic Doppler current profilers (ADCPs) for determining flow in open channels. It describes a number of methods of deploying ADCPs to determine flow. Although, in some cases, these measurements are intended to determine the stage-discharge relationship of a gauging station, this document deals only with single determination of discharge. ADCPs can be used to measure a variety of parameters, such as current or stream flow, water velocity fields, and channel bathymetry. As a potential application, an idea of bedload discharge can be obtained applying the bottom track velocity, while suspended sediment flow can be obtained applying the acoustic backscatter and the sonar equation. This document is generic in form and contains no operational details specific to particular ADCP makes and models.

  • Standard
    49 pages
    English language
    sale 15% off
  • Standard
    51 pages
    French language
    sale 15% off
  • Draft
    49 pages
    English language
    sale 15% off
  • Draft
    49 pages
    French language
    sale 15% off

This document specifies a calibration method for mechanical type, electromagnetic type and acoustic type hydrometric current-meters used for point velocity measurement of flowing water. The method requires towing the instrument through still water in a straight open tank. It includes measuring apparatus, the calibration procedure, the method of presenting the results and the uncertainties associated with the method.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 15% off

This document provides an understanding of the nature of measurement uncertainty and its significance in estimating the "quality" of a measurement or a determination in hydrometry. This document is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

  • Standard
    70 pages
    English language
    sale 15% off
  • Standard
    73 pages
    French language
    sale 15% off
  • Draft
    70 pages
    English language
    sale 15% off
  • Draft
    71 pages
    French language
    sale 15% off

This document specifies methods of determining the stage?discharge relationship for gauging stations. It specifies an accuracy for defining the stage?discharge relationship based on a sufficient number of discharge measurements, complete with corresponding stage measurements. This document considers stable and unstable channels and includes brief descriptions of the effects on the stage?discharge relationship of the transition from inbank to overbank flows, shifting controls, variable backwater and hysteresis. Methods of determining discharge for twin-gauge stations, ultrasonic velocity-measurement stations and other complex rating curves are not described in detail. NOTE These types of rating curves are described separately in other International Standards, Technical Specifications and Technical Reports, which are listed in the Bibliography.

  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    48 pages
    French language
    sale 15% off

This document specifies methods for the measurement of the flow of water in open channels under steady flow conditions using triangular profile weirs. The flow conditions considered are steady flows which are uniquely dependent on the upstream head and non-modular (drowned) flows which depend on downstream as well as upstream levels.

  • Standard
    30 pages
    English language
    sale 15% off
  • Standard
    30 pages
    English language
    sale 15% off

This document gives guidelines for selecting a particular type of flow measuring structure for measuring liquid flow in an open channel. It describes how the individual structures function in simple non-technical terms, and sets out the factors and parameters to take into account in order to make an informed decision on which type of structure to use. Values of the relevant parameters describing the limitations and uncertainty involved in the use of these structures are given in this document. More definitive details of a particular type of structure are given in the individual standards listed in Table 1, which cover each type of structure.

  • Standard
    23 pages
    English language
    sale 15% off

This standard describes procedures for determining and verifying the declared values of the noise emitted by household and similar appliances. It applies to all categories of household and similar electrical appliances covered by IEC 60704-1 and all parts of IEC 60704-2, which include particular requirements for special categories of appliances. It applies to appliances being produced in quantity, such as in batches, series or lots, which are manufactured to the same technical specification and characterized by the same declared value of noise emission. This part of IEC 60704: - considers the term "declaration" to include all means for providing information on the noise emission values to potential users (consumers) of the appliances; this includes labels, brochures, advertisements, commercial and technical information papers, etc.; - considers the declaration for appliances manufactured by mass production; - specifies a simple statistical method for verifying the declared values by investigating a sample of only three appliances.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method of determining discharge in open channels from observations of the surface slope and cross-sectional area of the channel. It is applicable to use under special conditions when direct measurement of discharge by typically more accurate methods, such as the velocity-area method, is not possible. Generally, the method can be used to determine discharge a) for a peak flow that left high-water marks along the stream banks, b) for a peak flow that left marks on a series of water-level gauges or where peak stages were recorded by that series of gauges, and c) for flow observed at the time of determining gauge heights from a series of gauges. The method is commonly used to undertake the extension of stage?discharge relationships above the highest gauged flows. It does not apply to determining discharges in tidal reaches.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off

ISO 6416 describes the establishment and operation of an ultrasonic (transit-time) gauging station for the continuous measurement of discharge in a river, an open channel or a closed conduit. It also describes the basic principles on which the method is based, the operation and performance of associated instrumentation and procedures for commissioning.
It is limited to the "transit time of ultrasonic pulses" technique, and is not applicable to systems that make use of the "Doppler shift" or "correlation" or "level-to-flow" techniques.
ISO 6416 is not applicable to measurement in rivers with ice.
NOTE       ISO 6416 focuses on open channel flow measurement. IEC 60041 covers the use of the technique for full pipe flow measurement.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines the requirements for the use of rectangular and triangular (V-notch) thin-plate
weirs for the measurement of flow of clear water in open channels under free flow conditions. It includes
the requirements for the use of full-width rectangular thin-plate weirs in submerged (drowned) flow
conditions.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    60 pages
    English language
    sale 15% off
  • Standard
    60 pages
    French language
    sale 15% off
  • Standard
    60 pages
    French language
    sale 15% off

This document describes the establishment and operation of an ultrasonic (transit-time) gauging
station for the continuous measurement of discharge in a river, an open channel or a closed conduit.
It also describes the basic principles on which the method is based, the operation and performance of
associated instrumentation and procedures for commissioning.
It is limited to the “transit time of ultrasonic pulses” technique, and is not applicable to systems that
make use of the “Doppler shift” or “correlation” or “level-to-flow” techniques.
This document is not applicable to measurement in rivers with ice.
NOTE This document focuses on open channel flow measurement. IEC 60041 covers the use of the technique
for full pipe flow measurement.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 18481:2017 specifies a method for the estimation of the sub-critical flow of clear water in a smooth, essentially horizontal channel (or a gently sloping channel), abruptly discontinued at bottom by a hydraulic structure, with a vertical drop and discharging freely. Such an overfall forms a control section and offers a means for the estimation of flow using the end depth measurement method. A wide variety of channel cross-sections with overfall have been studied, but only those which have received general acceptance after adequate research and testing, and therefore do not require in situ calibration, are considered. This document covers channels with the following types of cross-sections: a) rectangular with confined and unconfined nappe; b) trapezoidal; c) triangular; d) circular; e) parabolic. The flow at the brink is curvilinear; therefore, the measured depth at the drop is not equal to the critical depth as computed by the principle based on assumption of parallel flow. However, the end depth and the critical depth (as in the case of the assumption of parallel flow) have unique relation, which is used to estimate the flow through these structures.

  • Standard
    20 pages
    English language
    sale 15% off

ISO/TR 9210:2017 provides guidelines for discharge measurements in meandering and braided rivers, and from bridges, following the provisions of ISO 748.

  • Technical report
    7 pages
    English language
    sale 15% off

ISO 9123:2017 specifies methods for determining stage-fall-discharge relationships for a stream reach where variable backwater occurs either intermittently or continuously. Two gauging stations, a base reference gauge and an auxiliary gauge are required for gauge height measurements. A number of discharge measurements are required in order to calibrate the rating to the accuracy required by this document. The preparation of rating curves is not described in detail in this document. NOTE For a more detailed description of preparing rating curves, see the methods described in ISO 1100‑2.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    31 pages
    French language
    sale 15% off

ISO 6416 describes the establishment and operation of an ultrasonic (transit-time) gauging station for the continuous measurement of discharge in a river, an open channel or a closed conduit. It also describes the basic principles on which the method is based, the operation and performance of associated instrumentation and procedures for commissioning. It is limited to the "transit time of ultrasonic pulses" technique, and is not applicable to systems that make use of the "Doppler shift" or "correlation" or "level-to-flow" techniques. ISO 6416 is not applicable to measurement in rivers with ice. NOTE ISO 6416 focuses on open channel flow measurement. IEC 60041 covers the use of the technique for full pipe flow measurement.

  • Standard
    58 pages
    English language
    sale 15% off
  • Standard
    61 pages
    French language
    sale 15% off

ISO 1438:2017 defines the requirements for the use of rectangular and triangular (V-notch) thin-plate weirs for the measurement of flow of clear water in open channels under free flow conditions. It includes the requirements for the use of full-width rectangular thin-plate weirs in submerged (drowned) flow conditions.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    60 pages
    English language
    sale 15% off
  • Standard
    60 pages
    French language
    sale 15% off
  • Standard
    60 pages
    French language
    sale 15% off

ISO/TR 19234:2016 specifies the requirements for the integration of baffles on the downstream face of triangular profile flow measurement structures to aid the passage of fish.

  • Technical report
    13 pages
    English language
    sale 15% off

ISO 6420:2016 specifies methods of determining the position of hydrometric boats based on satellite navigation systems and/or with respect to known points on the banks of rivers, estuaries or lakes. It applies to electronic positioning equipment and conventional surveying techniques.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

ISO 24155:2016 specifies the technical requirements that should be considered in designing and operating hydrometric data transmission systems (HDTS) and also the necessary functions of those systems. The scope of HDTS is shown in Annex A.

  • Standard
    37 pages
    English language
    sale 15% off
  • Standard
    37 pages
    English language
    sale 15% off
  • Standard
    38 pages
    French language
    sale 15% off
  • Standard
    38 pages
    French language
    sale 15% off

ISO 29606:2015 specifies requirements for the integration of fishpasses with flow measurement structures. It identifies those fishpasses which have satisfactory hydrometric calibration data and gives methods for computing combined flows and uncertainties. NOTE Flow measurement structures and fishpasses have inherently different hydraulic performance criteria. Flow measurement structures perform better with uniform flow patterns; conversely, fish passage performance is improved by the variability of the flow conditions that allow fish and other aquatic inhabitants to select the passage conditions that best meet their mode of movement. This International Standard does not suggest that the fishpasses discussed are the preferred methods of fish passage or that they are good enough that passage performance can be sacrificed to obtain a single structure that meets both the fish passage and flow measurement requirements.

  • Standard
    48 pages
    English language
    sale 15% off

ISO/TR 11651:2015 describes a method for estimation/prediction of sediment deposition within and upstream of a reservoir using numerical simulation techniques through one-dimensional flow and sediment transport equations. Numerical simulation models for predicting sediment distribution are applicable for reservoirs, where the length of the reservoir greatly exceeds the depth and width and the reservoir has a significant through flow. ISO/TR 11651:2015 includes the theoretical basis and fundamental assumptions of the technique and provides a summary of some numerical methods used to solve the unsteady flow and sediment transport equations. Also provided are details on the application of the model, including data requirements, procedures for model calibration, validation, testing, applications and identification of uncertainties associated with the method. This Technical Report does not provide sufficient information for the development of a computer program for solving the equations, but rather is based on the assumption that an adequately documented computer program is available.

  • Technical report
    28 pages
    English language
    sale 15% off

ISO/TR 9212:2015 reviews the current status of direct and indirect bedload-measurement techniques. The methods are mainly based on grain size distribution of the bedload, channel width, depth, and velocity of flow. This Technical Report outlines and explains several methods for direct and indirect measurement of bedload in streams, including various types of sampling devices. The purposes of measuring bedload-transport rates are to a) increase the accuracy of estimating total sediment load in rivers and deposition in reservoirs, b) gain knowledge of bedload transport that cannot be completely measured by conventional suspended-sediment collection methods, c) provide data to calibrate or verify theoretical transport models, and d) provide information needed in the design of river diversion and entrainment structures. NOTE The units of measurement used in this Technical Report are SI units.

  • Technical report
    25 pages
    English language
    sale 15% off

ISO 4375:2014 defines the requirements for equipment, anchorage, supports and accessories for cableway systems for use in stream gauging. Systems which are operated either entirely from the river bank or from a suspended personnel carriage (also called a "cable car") are discussed. Should the cableway installation be required to be certified as lifting equipment, other standards or regulations may apply. ISO 4375:2014 is only applicable to the cableway systems to be used for hydrometric measurements.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard + National Annex and/or Foreword
    16 pages
    Foreword and/or annex in Slovenian language, body of the standard in German language
    sale 10% off
    e-Library read for
    1 day
  • Standard + National Annex and/or Foreword
    10 pages
    Foreword and/or annex in Slovenian language, body of the standard in German language
    sale 10% off
    e-Library read for
    1 day

This International Standard provides guidelines on the principles of operation and the selection and use of
Doppler-based and echo correlation velocity meters for continuous-flow gauging.
This International Standard is applicable to channel flow determination in open channels and partially filled
pipes using one or more meters located at fixed points in the cross-section.

  • Standard
    61 pages
    English language
    sale 15% off
  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard defines the requirements for equipment, anchorage, supports and
accessories for cableway systems for use in stream gauging. Systems which are operated either entirely
from the river bank or from a suspended personnel carriage (also called a “cable car”) are discussed.
This International Standard is only applicable to the cableway systems to be used for hydrometric
measurements. Should the cableway installation be required to be certified as lifting equipment, other
standards or regulations may apply. This International Standard does not concern methods for making
a discharge measurement which are described in ISO 748.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 4375:2014 defines the requirements for equipment, anchorage, supports and accessories for cableway systems for use in stream gauging. Systems which are operated either entirely from the river bank or from a suspended personnel carriage (also called a "cable car") are discussed. Should the cableway installation be required to be certified as lifting equipment, other standards or regulations may apply. ISO 4375:2014 is only applicable to the cableway systems to be used for hydrometric measurements.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off

ISO 18365:2013 gives requirements for the establishment and operation of a gauging station for the measurement of stage, or stage and discharge, of a lake, reservoir, river or canal or other artificial open channel. It also describes how a gauging station utilising one of the measurement methods listed should be operated and maintained.
Requirements are provided for stage only measurement stations, stage-discharge stations and direct-discharge measurement stations in natural channels, as well as for stage-discharge stations with artificial structures. Additionally, some requirements are given for measurements under difficult conditions, such as under ice conditions.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 11657:2014 specifies methods for determination of the concentrations and particle-size distributions of suspended sediment in streams and canals by surrogate techniques. ISO 11657:2014 covers brief description of the operating principle of each method and details of some of the instruments available.

  • Standard
    20 pages
    English language
    sale 15% off
  • Standard
    20 pages
    English language
    sale 15% off

EN-ISO 18365 gives requirements for the establishment and operation of a gauging station for the measurement of stage, or stage and discharge, of a lake, reservoir, river or canal or other artificial open channel. It also describes how a gauging station utilizing one of the measurement methods listed should be operated and maintained. Requirements are provided for stage only measurement stations, stage-discharge stations and directdischarge measurement stations in natural channels, as well as for stage-discharge stations with artificial structures. Additionally, some requirements are given for measurements under difficult conditions, such as under ice conditions.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day