This document specifies requirements and recommendations for the design and execution of an interlaboratory comparison for validation of new standardized analytical methods in the field of water analysis, e.g. the number of participating laboratories and time schedules. This document is based on ISO 5725-1 and ISO 5725-2. NOTE The scope of other standards in the field of interlaboratory comparison, such as ISO/IEC 17043[3] and ISO 13528[1], is proficiency testing of analytical laboratories and not interlaboratory comparison for the validation of analytical methods.

  • Technical specification
    8 pages
    English language
    sale 15% off
  • Draft
    9 pages
    English language
    sale 15% off
  • Draft
    9 pages
    English language
    sale 15% off

This European Standard specifies general requirements and performance test procedures for portable and fixed position measuring devices (MDs) that are used in an in-line or online operating position to measure physical and chemical determinands in water. It excludes at-line devices, such as chemical test kits, and off-line devices, such as laboratory analysers.
The general requirements include functional facilities that MDs need to meet users’ applications and information that need to be included in associated documents.
The test procedures specify uniform methods to be used when determining key performance characteristics of MDs. The performance tests comprise testing carried out under laboratory and field conditions.
Statistical procedures are defined for evaluation of the test data. It is recognized that for some devices certain test procedures are not applicable.
Example values for performance characteristics for a selection of MDs for monitoring waste water effluents and receiving waters are detailed in Annex A for guidance.
This European Standard requires the manufacturer of a MD to provide more technical data for verification than does EN ISO 15839:2006 [5]. Consequently, EN ISO 15839 will be of greater assistance to manufacturers wishing to characterize a new device whereas this European Standard is more focussed on user requirements for the verification of manufacturer’s claims.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines general requirements, performance requirements and conformity test procedures for automated sampling devices (samplers) for water and waste water that:
-   sample water and waste water from non-pressurized (i. e. open to atmosphere) channels or vessels;
-   sample over extended periods to collect discrete or composite samples based on time, event or flow proportional sampling.
Specific sample integrity requirements are defined for samplers to be used for the collection of samples of final effluent or influent for the purpose of monitoring the performance of waste water treatment works, as required under the Urban Waste Water Treatment Directive (UWWTD). Samplers to be used for other industrial applications do not have to be assessed against these specific sample integrity requirements.
This European Standard does not cover the installation and on-going use of samplers.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document sets out the general principles for, and provides guidance on, the design of sampling programmes and sampling techniques for all aspects of sampling of water (including waste waters, sludges, effluents, suspended solids and sediments).
It does not include detailed instructions for specific sampling situations, which are covered in the various other parts of ISO 5667 and in ISO 19458.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Water sampling for capture of environmental DNA (eDNA) in aquatic environments. eDNA stems from organisms which are or have recently been living in the water body and does not include eDNA found in sediments or similar sample types. Covers procedures for avoiding sample contamination and ensuring DNA quality, key properties of the filtering procedure and equipment, and reporting standards.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document sets out the general principles for, and provides guidance on, the design of sampling programmes and sampling techniques for all aspects of sampling of water (including waste waters, sludges, effluents, suspended solids and sediments).
This document does not include detailed instructions for specific sampling situations, which are covered in various other parts of the ISO 5667 series and in ISO 19458.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies general requirements and performance test procedures for portable and fixed position measuring devices (MDs) that are used in an in-line or online operating position to measure physical and chemical determinands in water. It excludes at-line devices, such as chemical test kits, and off-line devices, such as laboratory analysers.
The general requirements include functional facilities that MDs need to meet users’ applications and information that need to be included in associated documents.
The test procedures specify uniform methods to be used when determining key performance characteristics of MDs. The performance tests comprise testing carried out under laboratory and field conditions.
Statistical procedures are defined for evaluation of the test data. It is recognized that for some devices certain test procedures are not applicable.
Example values for performance characteristics for a selection of MDs for monitoring waste water effluents and receiving waters are detailed in Annex A for guidance.
This European Standard requires the manufacturer of a MD to provide more technical data for verification than does EN ISO 15839:2006 [5]. Consequently, EN ISO 15839 will be of greater assistance to manufacturers wishing to characterize a new device whereas this European Standard is more focussed on user requirements for the verification of manufacturer’s claims.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements, performance requirements and conformity test procedures for automatic sampling devices (samplers) for water and waste water that:
—   sample water and waste water from non-pressurized (i.e. open to atmosphere) channels or vessels;
—   sample over extended periods to collect discrete or composite samples based on time, event or flow proportional sampling.
It does not include sampling systems built into online and in-line analysers.
The general requirements include functional facilities that samplers need to meet users’ applications and information that needs to be included in associated documents.
The test procedures specify uniform methods to be used when determining key performance characteristics of samplers at one or more set sample volume. It is for the sampler manufacturer and/or user to decide on the required set sample volume(s). All of the test procedures are to be carried out under laboratory conditions. It is recognized that for some samplers, certain test procedures are not applicable.
Statistical procedures are specified for evaluation of the test data. Some example calculations are provided.
Specific sample integrity requirements are specified for samplers to be used for the collection of samples of final effluent or influent for the purpose of monitoring the performance of urban waste water treatment works. Samplers to be used for other industrial applications do not need to be assessed against these specific sample integrity requirements.
This document does not cover the installation and on-going use of samplers.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document sets out the general principles for, and provides guidance on, the design of sampling programmes and sampling techniques for all aspects of sampling of water (including waste waters, sludges, effluents, suspended solids and sediments). This document does not include detailed instructions for specific sampling situations, which are covered in various other parts of the ISO 5667 series and in ISO 19458.

  • Standard
    39 pages
    English language
    sale 15% off
  • Draft
    39 pages
    English language
    sale 15% off
  • Draft
    39 pages
    English language
    sale 15% off

The purpose of this document is to describe test plans and different operating methodologies of these test plans to define and verify the acceptable length of stability of a substance in a sample under specified conditions of preservation (temperature, matrix, light, addition of a stabilizer, where appropriate, type of preservation etc.) before starting analytical protocols (chemicals and physico-chemicals analysis). Biological and microbiological methods are excluded.
It is necessary to have an analytical method with performances that have already been characterized (repeatability, intermediate precision, trueness, accuracy and uncertainty) in order to perform the stability study and implement its test plans.

  • Technical specification
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    50 pages
    English language
    sale 15% off
  • Draft
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    49 pages
    English language
    sale 15% off

This document specifies how to collect discrete seawater samples, from a Niskin or other water sampler, that are suitable for the analysis of the four measurable inorganic carbon parameters: total dissolved inorganic carbon, total alkalinity, pH and CO2 fugacity.

  • Standard
    11 pages
    English language
    sale 15% off

The purpose of this document is to describe test plans and different operating methodologies of these test plans to define and verify the acceptable length of stability of a substance in a sample under specified conditions of preservation (temperature, matrix, light, addition of a stabilizer, where appropriate, type of preservation etc.) before starting analytical protocols (chemicals and physico-chemicals analysis). Biological and microbiological methods are excluded. It is necessary to have an analytical method with performances that have already been characterized (repeatability, intermediate precision, trueness, accuracy and uncertainty) in order to perform the stability study and implement its test plans.

  • Technical specification
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    50 pages
    English language
    sale 15% off
  • Draft
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    49 pages
    English language
    sale 15% off

This document contains details on the sampling of domestic and industrial waste water, i.e. the design of sampling programmes and techniques for the collection of samples. It covers waste water in all its forms, i.e. industrial waste water, radioactive waste water, cooling water, raw and treated domestic waste water.
It deals with various sampling techniques used and the rules to be applied so as to ensure the samples are representative.
Sampling of accidental spillages is not included, although the methods described in certain cases may also be applicable to spillages.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    45 pages
    English language
    sale 15% off
  • Draft
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    44 pages
    English language
    sale 15% off

This document sets out the general principles for, and provides guidance on, the design of sampling programmes and sampling techniques for all aspects of sampling of water (including waste waters, sludges, effluents, suspended solids and sediments). It does not include detailed instructions for specific sampling situations, which are covered in the various other parts of ISO 5667 and in ISO 19458.

  • Standard
    39 pages
    English language
    sale 15% off
  • Standard
    42 pages
    French language
    sale 15% off
  • Standard
    42 pages
    French language
    sale 15% off
  • Draft
    39 pages
    English language
    sale 15% off

This document specifies requirements and gives guidance for performing the manipulations common
to each culture technique for the microbiological examination of water, particularly the preparation of
samples, culture media, and general apparatus and glassware, unless otherwise required in the specific
standard. It also describes the various techniques available for detection and enumeration by culture
and the criteria for determining which technique is appropriate.
This document is mainly intended for examinations for bacteria, yeasts and moulds, but some aspects
are also applicable to bacteriophages, viruses and parasites. It excludes techniques not based on
culturing microorganisms, such as polymerase chain reaction (PCR) methods.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements for sampling, preservation, handling, transport and storage of all water samples including those for biological analyses.
It is not applicable to water samples intended for microbiological analyses as specified in ISO 19458, ecotoxicological assays, biological assays and passive sampling as specified in the scope of ISO 5667‑23.
This document is particularly appropriate when spot or composite samples cannot be analysed on site and have to be transported to a laboratory for analysis.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements for sampling, preservation, handling, transport and
storage of all water samples including those for biological analyses.
It is not applicable to water samples intended for microbiological analyses as specified in ISO 19458,
ecotoxicological assays, biological assays and passive sampling as specified in the scope of ISO 5667-23.
This document is particularly appropriate when spot or composite samples cannot be analysed on site
and have to be transported to a laboratory for analysis.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides guidance on the sampling of unconsolidated sediments for the determination
of their geological, physical and chemical properties, as well as the determination of biological,
microbiological and chemical properties at the water and sediment interface. Guidance on achieving
sediment cores is given specifically for the measurement of rates of deposition and detailed strata
delineation. The main emphasis of this document is to provide methods that achieve sediment samples.
The environments considered are
— limnic (rivers, streams and lakes, natural and man-made), and
— estuarine, including harbours.
Industrial and sewage works for sludges, paleolimnological sampling and sampling of open ocean
sediments are specifically excluded from this document (and are addressed in ISO 5667-15), although
some techniques may apply to these situations. Sampling of suspended solids is outside the scope of
this document and reference can be made to ISO 5667-17 for such guidance.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    47 pages
    English language
    sale 15% off
  • Draft
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 provides an audit protocol to monitor conformity with declared, or assumed,
practices in all areas of water quality sampling. Specifically, this part of ISO 5667 provides guidance on
the systematic assessment of sampling practices and procedures in the field, and assessing conformity
with those given in the organization’s sampling manual. It is applicable to the audit of sampling activities
from the development of a sampling manual through to the delivery of samples to the laboratory.
NOTE 1 The design of the sampling manual is the prerogative of the data user and this part of ISO 5667 is not
intended to deliver criticism of a manual’s structure.
This part of ISO 5667 is applicable to sampling practices associated with wastewaters, including
discharges to water bodies, environmental monitoring, potable water supplies from source to tap,
commercial and industrial uses of water, and power generation.
This part of ISO 5667 is applicable to the auditing of sampling practices relevant to the management
of water stored in containers, such as temporary supply tanks and bottled supplies. However, it is not
applicable for the auditing (or calibration and maintenance) of on-site test equipment or kits.
NOTE 2 BS 1427 covers water test kits used “in the field”.
The following sampling occasions are excluded from both the field- and desk-audit procedures set out
in this part of ISO 5667:
a) chemical and microbiological incidents, which are investigated by agencies such as the emergency
services, e.g. where an immediate risk to the health of the sampling practitioner/operative is evident;
b) radiochemical sampling of water quality, other than that specified as a routine requirement under
the UK Water Supply (Water Quality) Regulations,[9][10][11][12] i.e. radiochemical incidents which
are investigated by agencies such as the emergency services.
Informative Annex A contains a series of forms to assist with auditing. These are for guidance only.
Informative Annex B gives procedures for monitoring temperature control, while Informative Annex C
provides guidance on measuring the uncertainty associated with sampling practices.

  • Standard
    97 pages
    English language
    sale 15% off
  • Standard
    104 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    104 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 gives guidelines for the design of sampling programmes, techniques and the
handling and preservation of samples of water, from natural and man-made lakes during open-water
and ice-covered conditions. This part of ISO 5667 is applicable to lakes with and without aquatic
vegetation.
Guidance on sampling for microbiological examination is not included.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    34 pages
    English language
    sale 15% off
  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document aims to serve as technical guidelines for the assessment and management of the health risks associated with pathogens contained in reclaimed water, which are expected to be caused by the use of reclaimed water, and/or by the production, storage, and transportation of reclaimed water. This document is applicable to the use of reclaimed water made from any source water (i.e. raw sanitary sewage; treated municipal wastewater; industrial wastewater; stormwater potentially influenced by sewage) and for non-potable water reuse. NOTE The approach described in this document can be applied to chemical contaminant, if applicable.

  • Standard
    23 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

This document specifies general requirements for sampling, preservation, handling, transport and storage of all water samples including those for biological analyses. It is not applicable to water samples intended for microbiological analyses as specified in ISO 19458, ecotoxicological assays, biological assays and passive sampling as specified in the scope of ISO 5667‑23. This document is particularly appropriate when spot or composite samples cannot be analysed on site and have to be transported to a laboratory for analysis.

  • Standard
    52 pages
    English language
    sale 15% off
  • Standard
    46 pages
    French language
    sale 15% off

ISO 5667-16:2017 gives practical guidance on sampling, pre-treatment, performance and evaluation of environmental samples in the context of performing biological tests. Information is given on how to cope with the problems of biotesting arising from the sample and the suitability of the test design.
It is intended to convey practical experience concerning precautions to be taken by describing methods successfully proven to solve or to circumvent some of the experimental problems of biotesting of, for example, waters.
Primarily dealt with are substance-related problems concerning sampling and pre-treatment of environmental samples (e.g. waste water samples) for the performance of biotests.
This guidance is on ecotoxicological testing with organisms (single-species biotests; in vivo and in vitro). Some features addressed in this document also apply to biotests using single-cell systems (in vitro bioassays) and biodegradation studies as far as sampling and sample preparations are concerned. Testing of substances in the water solubility range is also addressed.
Reference has been made as far as possible to existing International Standards and guidelines. Information taken from published papers or oral communication has been utilized as well.
ISO 5667-16:2017 is applicable to biological tests for determining the effect of environmental samples like treated communal and industrial waste water, groundwater, fresh water, aqueous extracts (e.g. leachates, eluates), pore water of sediments and whole sediments. This document is also applicable to chemical substances.
ISO 5667-16:2017 is not applicable to bacteriological examination of water. Appropriate methods for bacteriological examination are described in other documents (see ISO 19458[17]).

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard provides guidance on determining the degree of modification of lake hydromorphological features described in EN 16039. It enables consistent comparisons of hydromorphology between lakes within a country and between different countries in Europe, providing a method for broad based characterization across a wide spectrum of hydromorphological modification. Its primary aim is to assess ‘departure from naturalness’ for a given type of lake as a result of human pressures, and it suggests suitable sources of information that may contribute to characterizing the degree of modification of hydromorphological features. For wholly artificial lakes or reservoirs formed by damming rivers the aim is to assess the extent to which processes approximate to those in comparable natural water bodies. However, this standard does not replace methods that have been developed within particular countries for local assessment and reporting. Decisions on management for individual lakes require expert local knowledge and vary according to lake type.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-12:2017 provides guidance on the sampling of unconsolidated sediments for the determination of their geological, physical and chemical properties, as well as the determination of biological, microbiological and chemical properties at the water and sediment interface. Guidance on achieving sediment cores is given specifically for the measurement of rates of deposition and detailed strata delineation. The main emphasis of this document is to provide methods that achieve sediment samples. The environments considered are - limnic (rivers, streams and lakes, natural and man-made), and - estuarine, including harbours. Industrial and sewage works for sludges, paleolimnological sampling and sampling of open ocean sediments are specifically excluded from this document (and are addressed in ISO 5667-15), although some techniques may apply to these situations. Sampling of suspended solids is outside the scope of this document and reference can be made to ISO 5667-17 for such guidance.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    47 pages
    English language
    sale 15% off
  • Draft
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 provides guidance on the selection and use of various quality assurance and quality
control techniques relating to the manual sampling of surface, potable, waste, marine and ground waters.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 sets out the principles to be applied to the design of sampling programmes, sampling techniques, and the handling of water samples from rivers and streams for physical and chemical assessment. It is not applicable to the sampling of estuarine or coastal waters nor for microbiological sampling.
NOTE 1 Procedures for microbiological sampling are given in ISO 19458.
This part of ISO 5667 is neither applicable to the examination of sediment, suspended solids or biota, nor to dammed stretches of rivers or streams. Also, it is not applicable to passive sampling of surface waters (see ISO 5667‑23).
NOTE 2 In cases where naturally occurring or artificially constructed dams result in the retention or storage of water for several days or more, the stretch of the river or stream should be considered as a standing water body. For sampling purposes, see ISO 5667‑4.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-16:2017 gives practical guidance on sampling, pre-treatment, performance and evaluation of environmental samples in the context of performing biological tests. Information is given on how to cope with the problems of biotesting arising from the sample and the suitability of the test design. It is intended to convey practical experience concerning precautions to be taken by describing methods successfully proven to solve or to circumvent some of the experimental problems of biotesting of, for example, waters. Primarily dealt with are substance-related problems concerning sampling and pre-treatment of environmental samples (e.g. waste water samples) for the performance of biotests. This guidance is on ecotoxicological testing with organisms (single-species biotests; in vivo and in vitro). Some features addressed in this document also apply to biotests using single-cell systems (in vitro bioassays) and biodegradation studies as far as sampling and sample preparations are concerned. Testing of substances in the water solubility range is also addressed. Reference has been made as far as possible to existing International Standards and guidelines. Information taken from published papers or oral communication has been utilized as well. ISO 5667-16:2017 is applicable to biological tests for determining the effect of environmental samples like treated communal and industrial waste water, groundwater, fresh water, aqueous extracts (e.g. leachates, eluates), pore water of sediments and whole sediments. This document is also applicable to chemical substances. ISO 5667-16:2017 is not applicable to bacteriological examination of water. Appropriate methods for bacteriological examination are described in other documents (see ISO 19458[17]).

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

ISO 5667-6:2014 sets out the principles to be applied to the design of sampling programmes, sampling techniques, and the handling of water samples from rivers and streams for physical and chemical assessment.
It is not applicable to the sampling of estuarine or coastal waters nor for microbiological sampling. (Procedures for microbiological sampling are given in ISO 19458.)
ISO 5667-6:2014 is neither applicable to the examination of sediment, suspended solids or biota, nor to dammed stretches of rivers or streams. Also, it is not applicable to passive sampling of surface waters (see ISO 5667‑23).
In cases where naturally occurring or artificially constructed dams result in the retention or storage of water for several days or more, the stretch of the river or stream should be considered as a standing water body. For sampling purposes, see ISO 5667‑4.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-14:2014 provides guidance on the selection and use of various quality assurance and quality control techniques relating to the manual sampling of surface, potable, waste, marine and ground waters.
NOTE          The general principles outlined in this part of ISO 5667 might, in some circumstances, be applicable to sludge and sediment sampling.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-4:2016 gives guidelines for the design of sampling programmes, techniques and the handling and preservation of samples of water, from natural and man-made lakes during open-water and ice-covered conditions. It is applicable to lakes with and without aquatic vegetation. Guidance on sampling for microbiological examination is not included.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    34 pages
    English language
    sale 15% off
  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-24:2016 provides an audit protocol to monitor conformity with declared, or assumed, practices in all areas of water quality sampling. Specifically, this part of ISO 5667 provides guidance on the systematic assessment of sampling practices and procedures in the field, and assessing conformity with those given in the organization's sampling manual. It is applicable to the audit of sampling activities from the development of a sampling manual through to the delivery of samples to the laboratory. NOTE 1 The design of the sampling manual is the prerogative of the data user and this part of ISO 5667 is not intended to deliver criticism of a manual's structure. ISO 5667-24:2016 is applicable to sampling practices associated with wastewaters, including discharges to water bodies, environmental monitoring, potable water supplies from source to tap, commercial and industrial uses of water, and power generation. ISO 5667-24:2016 is applicable to the auditing of sampling practices relevant to the management of water stored in containers, such as temporary supply tanks and bottled supplies. However, it is not applicable for the auditing (or calibration and maintenance) of on-site test equipment or kits. NOTE 2 BS 1427 covers water test kits used "in the field". The following sampling occasions are excluded from both the field- and desk-audit procedures set out in this part of ISO 5667: a) chemical and microbiological incidents, which are investigated by agencies such as the emergency services, e.g. where an immediate risk to the health of the sampling practitioner/operative is evident; b) radiochemical sampling of water quality, other than that specified as a routine requirement under the UK Water Supply (Water Quality) Regulations,[9][10][11][12] i.e. radiochemical incidents which are investigated by agencies such as the emergency services. Informative Annex A contains a series of forms to assist with auditing. These are for guidance only. Informative Annex B gives procedures for monitoring temperature control, while Informative Annex C provides guidance on measuring the uncertainty associated with sampling practices.

  • Standard
    97 pages
    English language
    sale 15% off
  • Standard
    104 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    104 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard + National Annex and/or Foreword
    17 pages
    Foreword and/or annex in Slovenian language, body of the standard in German language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 sets out the principles to be applied to the design of sampling programmes,
sampling techniques, and the handling of water samples from rivers and streams for physical and
chemical assessment.
It is not applicable to the sampling of estuarine or coastal waters nor for microbiological sampling.
NOTE 1 Procedures for microbiological sampling are given in ISO 19458.[10]
This part of ISO 5667 is neither applicable to the examination of sediment, suspended solids or biota, nor
to dammed stretches of rivers or streams. Also, it is not applicable to passive sampling of surface waters
(see ISO 5667‑23).
NOTE 2 In cases where naturally occurring or artificially constructed dams result in the retention or storage
of water for several days or more, the stretch of the river or stream should be considered as a standing water body.
For sampling purposes, see ISO 5667‑4.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    28 pages
    French language
    sale 15% off

This part of ISO 5667 provides guidance on the selection and use of various quality assurance and quality
control techniques relating to the manual sampling of surface, potable, waste, marine and ground waters.
NOTE The general principles outlined in this part of ISO 5667 might, in some circumstances, be applicable to
sludge and sediment sampling.

  • Standard
    35 pages
    English language
    sale 15% off
  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    37 pages
    French language
    sale 15% off
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-14:2014 provides guidance on the selection and use of various quality assurance and quality control techniques relating to the manual sampling of surface, potable, waste, marine and ground waters. NOTE The general principles outlined in this part of ISO 5667 might, in some circumstances, be applicable to sludge and sediment sampling.

  • Standard
    35 pages
    English language
    sale 15% off
  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    37 pages
    French language
    sale 15% off
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-6:2014 sets out the principles to be applied to the design of sampling programmes, sampling techniques, and the handling of water samples from rivers and streams for physical and chemical assessment. It is not applicable to the sampling of estuarine or coastal waters nor for microbiological sampling. (Procedures for microbiological sampling are given in ISO 19458.) ISO 5667-6:2014 is neither applicable to the examination of sediment, suspended solids or biota, nor to dammed stretches of rivers or streams. Also, it is not applicable to passive sampling of surface waters (see ISO 5667‑23). In cases where naturally occurring or artificially constructed dams result in the retention or storage of water for several days or more, the stretch of the river or stream should be considered as a standing water body. For sampling purposes, see ISO 5667‑4.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    28 pages
    French language
    sale 15% off

This International Standard specifies methods for the estimation of measurement uncertainty of chemical and physicochemical methods in single laboratories based on validation data and analytical quality control results obtained within the field of water analysis. NOTE 1 The principles of the estimation of uncertainty specified in this International Standard are consistent with the principles described in ISO/IEC Guide 98-3. In this International Standard, the quantification of measurement uncertainty relies on performance characteristics of a measurement procedure obtained from validation and the results of internal and external quality control. NOTE 2 The approaches specified in this International Standard are mainly based on QUAM[11], NEN 7779[8], Nordtest TR 537[10], and Eurolab TR 1[9]. NOTE 3 This International Standard only addresses the evaluation of measurement uncertainty for results obtained from quantitative measurement procedures. The uncertainties associated with results obtained from qualitative procedures
are not considered.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    26 pages
    French language
    sale 15% off

This Technical Specification provides comprehensive guidance on within-laboratory and between-laboratory quality control for ensuring the production of results with a known level of accuracy in the analysis of waters. This Technical Specification is applicable to the chemical and physicochemical analysis of all types of waters. It is not intended for application to the analysis of sludges and sediments (although many of its general principles are applicable to such analysis) and it does not address the biological or microbiological examination of water. Whilst sampling is an important aspect, this is only briefly considered. Analytical quality control, as described in this Technical Specification, is intended for application to water analysis carried out within a quality-assurance programme. This Technical Specification does not address the detailed requirements of quality assurance for water analysis, which can be found in the EURACHEM/CITACGuide (2002) [20]. The recommendations of this Technical Specification are in agreement with the requirements of established
quality-assurance documentation (e.g. ISO/IEC 17025). This Technical Specification is applicable to the use of all analytical methods within its field of application, although its detailed recommendations may require interpretation and adaptation to deal with certain types of determinands (for example, non-specific determinands, such as suspended solids or biochemical oxygen demand, BOD). In the event of any disparity between the recommendations of this Technical Specification
and the requirements of a standard method of analysis, the requirements of the method should prevail.

  • Technical specification
    39 pages
    English language
    sale 15% off
  • Technical specification
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    41 pages
    French language
    sale 15% off

This European Standard describes methods, requirements and equipment for remote visual surveillance of organisms and the seabed using still photography and video recording to ensure precise and reproducible data. The main aims of the methods are to record or monitor seabed conditions and organisms on and just above the seabed in a reproducible way at a resolution that is appropriate to the aims of the survey. In caves and overhangs this standard may not be suitable due to technological limitations related to navigation and movement of the observation platform.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard provides guidance on interlaboratory comparison with a special focus on biological methods. Guidance on the methods and procedures given in this standard should ensure that field survey results and laboratory analyses are comparable within specified limits. This guidance enables participants in interlaboratory comparison to demonstrate their level of performance. In addition it provides a mechanism for quality improvement. This standard describes a general course of the procedure. Detailed elements can be found in EN 14996, EN ISO/IEC 17000, EN ISO/IEC 17025, and EN ISO/IEC 17043.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes methods, requirements and equipment for remote visual surveillance of organisms and the seabed using still photography and video recording to ensure precise and reproducible data. The main aims of the methods are to record or monitor seabed conditions and organisms on and just above the seabed in a reproducible way at a resolution that is appropriate to the aims of the survey.
In caves and overhangs this standard may not be suitable due to technological limitations related to navigation and movement of the observation platform.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard provides guidance on interlaboratory comparison with a special focus on biological methods. Guidance on the methods and procedures given in this standard should ensure that field survey results and laboratory analyses are comparable within specified limits. This guidance enables participants in interlaboratory comparison to demonstrate their level of performance. In addition it provides a mechanism for quality improvement. This standard describes a process structure. Detailed elements can be found in EN 14996, EN ISO/IEC 17000, EN ISO/IEC 17025, and EN ISO/IEC 17043.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies methods for the estimation of measurement uncertainty of chemical and physicochemical methods in single laboratories based on validation data and analytical quality control results obtained within the field of water analysis. NOTE 1 The principles of the estimation of uncertainty specified in this International Standard are consistent with the principles described in ISO/IEC Guide 98-3. In this International Standard, the quantification of measurement uncertainty relies on performance characteristics of a measurement procedure obtained from validation and the results of internal and external quality control. NOTE 2 The approaches specified in this International Standard are mainly based on QUAM[11], NEN 7779[8], Nordtest TR 537[10], and Eurolab TR 1[9]. NOTE 3 This International Standard only addresses the evaluation of measurement uncertainty for results obtained from quantitative measurement procedures. The uncertainties associated with results obtained from qualitative procedures are not considered.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    26 pages
    French language
    sale 15% off

This part of ISO 5667 gives guidance on the sampling of sludges from wastewater treatment works, water treatment works and industrial processes. It is applicable to all types of sludges arising from these works and also to sludges of similar characteristics, for example septik tank sludges. Guidance is also given on the design of sampling programmes and techniques for the collection of samples.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-13:2011 gives guidance on the sampling of sludges from wastewater treatment works, water treatment works and industrial processes. It is applicable to all types of sludge arising from these works and also to sludges of similar characteristics, e.g. septic tank sludges. Guidance is also given on the design of sampling programmes and techniques for the collection of samples.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5667-23:2011 specifies procedures for the determination of time-weighted average concentrations and equilibrium concentrations of the free dissolved fraction of organic and organometallic compounds and inorganic substances, including metals, in surface water by passive sampling, followed by analysis.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 establishes principles to be applied to the techniques of sampling water provided for drinking and for use in the manufacture of food and beverage products.
The guidance given in this part of ISO 5667 is generally confined to those circumstances where water is drawn from municipal or similar public or private abstraction, treatment or distribution systems for which prior treatment or quality assessment has resulted in the water being classified as suitable for drinking or potable process purposes. Specifically, this part of ISO 5667 is applicable to water that is supplied by tanker or other non-contiguous bulk means, but not contiguously as part of a piped distribution system, during any stage of use up to and including the point of consumption or transfer to a piped distribution system. This part of ISO 5667 is also applicable to the distribution and bulk storage of water on aircraft, trucks, trains, ships, and other vessels and vehicles, as well as to sampling situations that can arise during the investigation of system defects, initiation of new systems, re-initiation of systems that have been unused for long periods or emergency situations where the safety of sampling operatives is not compromised.
This part of ISO 5667 does not provide guidance on:
a) the sampling of source water, e.g. groundwater and impoundments;
b) the sampling of potable water supplies derived from contiguous piped supplies covered by ISO 5667-5;
c) the sampling of beverage products (including bottled waters) or food containing potable water used in its preparation;
d) the sampling of drink vending machines.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English language
    sale 10% off