This document deals with the requirements for the ferrule-securing of eyes and endless loops.
It also deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops.
This document applies to the ferrule-securing of eye terminations formed either by a Flemish eye or turn-back eye and covers ferrules made of non alloy carbon steel and aluminium.
This document applies to slings and assemblies using steel wire ropes for general lifting applications up to and including 60 mm diameter conforming to EN 12385-4, lift ropes conforming to EN 12385-5 and spiral strand ropes conforming to EN 12385-10. It is approved for use on rope grades up to 1960. For use on rope grades higher than 1960, the designer/ manufacturer must satisfy the testing requirements of this document.
Type testing of ferrule-secured systems and manufacturing quality control requirements are also specified.
This document deals with all significant hazards, hazardous situations, and events relevant to this particular steel wire rope termination when used as intended and under conditions of use which are foreseeable by the manufacturer.
This document applies to terminations of steel wire ropes with ferrules and ferrule-securing which are manufactured after the date of this publication.
NOTE   One design of ferrule-secured turn-back eye termination using an oval aluminium ferule which satisfies the requirements of this document is given for information in Annex A.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document deals with the requirements for the ferrule-securing of eyes and endless loops.
It also deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops.
This document applies to the ferrule-securing of eye terminations formed either by a Flemish eye or turn-back eye and covers ferrules made of non-alloy carbon steel and aluminium.
This document applies to slings and assemblies using steel wire ropes for general lifting applications up to and including 60 mm diameter conforming to EN 12385-4, lift ropes conforming to EN 12385-5 and spiral strand ropes conforming to EN 12385-10.
Type testing of ferrule-secured systems and manufacturing quality control requirements are also specified.
This document deals with all significant hazards, hazardous situations, and events relevant to this particular steel wire rope termination when used as intended and under conditions of use which are foreseeable by the manufacturer.
This document applies to terminations of steel wire ropes with ferrules and ferrule-securing which are manufactured after the date of this publication.
NOTE   One design of ferrule-secured turn-back eye termination using an oval aluminium ferule which satisfies the requirements of this document when securing ropes having rope grades up to and including 1960 is given for information in Annex A.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements for symmetrical wedge socket terminations for stranded steel wire ropes conforming to EN 12385-5 for lifts.
This document covers those symmetric wedge sockets intended for use at temperatures between −20 °C and 100 °C.
This document only covers those symmetric wedge sockets that have welded socket bodies. An example of the construction and sizes of a symmetric wedge socket is given in informative Annex A.
The informative Annex B gives the recommendations for the safe use and inspection of symmetric wedge socket according to Annex A.
This document deals with all significant hazards, hazardous situations and events relevant to symmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
The hazards covered by this document are identified in Clause 4.
This document applies to symmetric wedge sockets, which are manufactured after the date of its publication.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements for solid thimbles made of steel or cast iron for terminations of stranded steel wire ropes.
This document is applicable to ferrule-secured terminations with solid thimbles in combination with ferrules (see EN 13411-3), that have an efficiency factor KT of at least 0,9, and to spliced terminations with solid thimbles (see EN 13411-2), that have an efficiency factor KT of at least 0,8, which are used as accessories for steel wire ropes, such as slings or wire rope assemblies, having a lifting, lowering or load-bearing effect in hoisting equipment.
Examples of designs of solid thimbles which meet the requirements of this standard are given in informative Annexes B and C.
Round thimbles (thimble with rotational symmetry around the bore) are not subject to this document.
This document is applicable to ferrule-secured terminations that are manufactured after the date of publication of this document.
Hazards that are dealt with in this document are listed in Clause 4.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements for symmetrical wedge socket terminations for stranded steel wire ropes conforming to prEN 12385-5 for lifts.
This document covers those symmetric wedge sockets intended for use at temperatures between -20 °C and 100 °C.
This document only covers those symmetric wedge sockets that have welded socket bodies. An example of the construction and sizes of a symmetric wedge socket is given in informative Annex A.
The informative Annex B gives the recommendations for the safe use and inspection of symmetric wedge socket according to Annex A.
This document deals with all significant hazards, hazardous situations and events relevant to symmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
The hazards covered by this European Standard are identified in Clause 4.
This document applies to symmetric wedge sockets, which are manufactured after the date of its publication.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification.
The object of this standard is to detail a standard method to assess the ability of a cableclamping device to allow rotary movement of the cable/wire bundle without damage to the external surface of the cable/wire bundle, the cable-clamping device, the connector or the sub-assembly.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a cableclamping device to prevent longitudinal movement of the cable/wire bundle.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a cableclamping device to withstand mechanical stresses likely to be encountered during normal usage.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a cableclamping device to prevent the rotation of the cable/wire bundle around its axis.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for non welded general purpose steel thimbles produced from plate having dimensions in accordance with Figure 1. The thimbles are intended to be used in slings made with six or eight strand steel wire ropes from 8 mm to 60 mm diameter complying with EN 12385-4.
Reeving thimbles and solid thimbles are not covered by this standard.
The hazards covered by this standard are identified in clause 4.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard has been prepared to provide a means of conforming with the essential safety requirements of the Machinery Directive and associated EFTA Regulations.
Purchasers ordering to this standard are advised to specify in their purchasing contract that the supplier operates a quality assurance system applicable to the relevant part of this standard (e.g. EN ISO 9001) to ensure themselves that products claimed to comply consistently achieve the required level of quality.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies minimum requirements for the splicing of eye terminations for six or eight strand steel wire ropes of up to 60 mm diameter complying with prEN 12385-4 used for slings to ensure that the spliced eye is strong enough to withstand a force of at least 80 % of the minimum breaking load of the rope.
Other hazards covered by this standard are identified in clause 4. Resistance to fatigue loading is not considered to be a significant hazard for slings and is not covered by this standard.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements, for asymmetrical wedge socket terminations for stranded steel wire ropes.
Examples of the construction and sizes of two separate designs of asymmetric wedge sockets are given in informative annexes A and B.
The informative annex C gives recommendations for safe use and inspection.
This European Standard deals with all significant hazards, hazardous situations and events relevant to asymmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
This standard applies to terminations of steel wire ropes with asymmetrical wedge sockets which are manufactured after the date of its publication.
This standard does not cover rope fatigue.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a method for testing the strength of fixing brackets intended to support plastics rainwater downpipe systems used externally on buildings. It is applicable to both metal and plastics brackets, and determines the amount of residual deformation after removal of a specified test load.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements for the ferrule-securing of eyes and endless loops.
It also deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops.
This European Standard applies to the ferrule-securing of eye terminations formed either by a Flemish eye or turn-back eye and covers ferrules made of non alloy carbon steel and aluminium.
This European Standard applies to slings and assemblies using steel wire ropes for general lifting applications up to and including 60mm diameter conforming to EN 12385-4, lift ropes conforming to EN 12385-5 and spiral strand ropes conforming to EN 12385-10.
Type testing of ferrule-secured systems and manufacturing quality control requirements are also specified.
This European standard deals with all significant hazards, hazardous situations and events relevant to this particular steel wire rope termination when used as intended and under conditions of use which are foreseeable by the manufacturer.
This standard applies to terminations of steel wire ropes with ferrules and ferrule-securing which are manufactured after the date of this publication.
NOTE   One design of ferrule-secured turn-back eye termination using an oval aluminium ferule which satisfies the requirements of this European Standard is given for information in annex A.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for symmetrical wedge socket terminations for stranded steel wire ropes conforming to EN 12385-5 for lifts.
This European Standard covers those symmetric wedge sockets intended for use at temperatures between
-20 °C and 100 °C.
This European Standard only covers those symmetric wedge sockets that have welded socket bodies.
An example of the construction and sizes of a symmetric wedge socket is given in informative Annex A.
The informative Annex B gives the recommendations for the safe use and inspection of symmetric wedge socket according to Annex A.
This European Standard deals with all significant hazards, hazardous situations and events relevant to symmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonable foreseeable by the manufacturer.
The hazards covered by this European Standard are identified in Clause 4.
This European Standard applies to symmetric wedge sockets, which are manufactured after the date of its publication.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for symmetrical wedge socket terminations for stranded steel wire ropes conforming to EN 12385-5 for lifts.
This European Standard covers those symmetric wedge sockets intended for use at temperatures between
-20 °C and 100 °C.
This European Standard only covers those symmetric wedge sockets that have welded socket bodies.
An example of the construction and sizes of a symmetric wedge socket is given in informative Annex A.
The informative Annex B gives the recommendations for the safe use and inspection of symmetric wedge socket according to Annex A.
This European Standard deals with all significant hazards, hazardous situations and events relevant to symmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonable foreseeable by the manufacturer.
The hazards covered by this European Standard are identified in Clause 4.
This European Standard applies to symmetric wedge sockets, which are manufactured after the date of its publication.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for the safe behaviour of terminations associated with U-bolt wire rope grips manufactured from ferrous materials for use as intended by the manufacturer of the U bolt grip.
Suitable uses include suspending static loads and single use lifting operations which have been assesseed by a competent person taking into account appropriate safety factors, frequency and duration of use.
This standard does not cover U-bolt wire rope grips as the primary securing devices on mine hoists, crane hoists or eye terminations for slings for general lifting service.
Examples of grips together with fitting instructions are given in informative annexes A and B.
The hazards covered by this standard are identified in clause 4.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for non welded general purpose steel thimbles produced from plate having dimensions in accordance with Figure 1. The thimbles are intended to be used in slings made with six or eight strand steel wire ropes from 8 mm to 60 mm diameter complying with prEN 12385-4:2001.
Reeving thimbles and solid thimbles are not covered by this standard.
The hazards covered by this standard are identified in clause 4.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day