CCMC - Correction of ToC, clause numbering
TC - Correction of Figure 534.1

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test procedures of switching devices for use in aircraft
electrical systems to EN 2282.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of HD 60364 deals with general requirements for isolation, switching, control and monitoring and with
the requirements for selection and erection of the devices provided to fulfil such functions.

  • Standardization document
    94 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-oflife). Sulphur hexafluoride (SF6), nitrogen (N2) and carbon tetrafluoride (CF4), are gases commonly used for electrical equipment. Taking into account environmental concerns, particular attention is paid to re-use criteria for SF6 and its mixtures with N2 and CF4 for its use in electrical equipment. Procedures for recovering and reclaiming used SF6 and its mixtures are outside the scope of this document and are described in IEC 62271-4. This document provides several annexes on the description of the different methods of analysis, on by-products, on the procedure for evaluating the potential health effects from byproducts, on cryogenic reclaiming of SF6, and on reclaiming recommendations. Storage, transportation and disposal of SF6 and its mixtures are outside the scope of this document and are covered by IEC 62271-4. Procedures to determine SF6 leakages are described in IEC 60068-2-17 [4]1. For the purposes of this document, the complementary gases used in SF6 mixtures will be limited to N2 or CF4.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-04-13: This A11 is created to allow citation in OJEU of EN IEC 61347-2-14:2018

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-08-05 NEXT ACTION: CCMC action by 2020-08-31
2020-08-03 CCMC to prepare request for BT
2020-08-03 since no 2nd assessment allowed, EC confirmed that TC met requirements for pos. ass.  
2019-02-20 PC: "lack of compliance" for LVD, TC to adress comments
2019-01-30 PC: Sent for LVD assessment
2018-03-22 - missing Annex ZZ - on hold
2017-10-05 - Cannot allocate for publication due to missing assessment from Consultant.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60364-5-53:2019 Deals with general requirements for isolation, switching and control and with the requirements for selection and erection of the devices provided to fulfil such functions. This fourth edition cancels and replaces the third edition published in 2001, Amendment 1:2002 and Amendment 2:2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all clauses except 531 and 534;
b) introduction of a new Clause 537 Monitoring;
c) Clause 530 contains all normative references and all terms and definitions.

  • Standard
    369 pages
    English and French language
    sale 15% off
  • Standard
    152 pages
    English and French language
    sale 15% off

IEC 61800-9-1:2017 specifies the general methodology to energy efficiency standardization for any extended product by using the guidance of the extended product approach (EPA). This document specifies the methodology of determination of losses of the extended product and its sub-parts. It is applicable to motor systems operated by a motor starter or by a converter (power drive systems).

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61800-9-2:2017 specifies energy efficiency indicators of power electronics (complete drive modules, CDM), power drive systems (PDS) and motor starters, all used for motor driven equipment. It specifies the methodology for the determination of losses of the complete drive module (CDM), the power drive system (PDS) and the motor system. It defines IE and IES-classes, their limit values and provides test procedures for the classification of the overall losses of the motor system. Furthermore, this document proposes a methodology for the implementation of the best energy efficiency solution of drive systems. This depends on the architecture of the motor driven system, on the speed/load profile and on the operating points over time of the driven equipment.

  • Standard
    112 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT Action: CCMC to make available
2019-03-06 - Sent to BT for approval of A nnex ZA/ZZ (approved=D162/C075)
2018-12-13 PeC: "Compliant" for LVD
2018-11-20 PeC: sent to BT to keep ratification pending in order to fix harmonization (approved D161/C072)
2018-11-12 PeC: submitted for HAS assessment
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT Action: CCMC to make available
2019-01-21 PeC: "Compliant" for LVD, sent to BT for integration (approved=D162/C043)
2018-11-21 PeC: sent to BT to keep ratification pending in order to fix harmonization (approved=D161/C073)
2018-11-12 PeC: submitted for HAS assessment
2017-07-31 - Cannot allocate for publication due to negative assessment from Consultant.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60480:2019 provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life).
Sulphur hexafluoride (SF6), nitrogen (N2) and carbon tetrafluoride (CF4), are gases commonly used for electrical equipment. Taking into account environmental concerns, particular attention is paid to re-use criteria for SF6 and its mixtures with N2 and CF4 for its use in electrical equipment. Procedures for recovering and reclaiming used SF6 and its mixtures are outside the scope of this document and are described in IEC 62271-4.
This document provides several annexes on the description of the different methods of analysis, on by-products, on the procedure for evaluating the potential health effects from by-products, on cryogenic reclaiming of SF6, and on reclaiming recommendations.
Storage, transportation and disposal of SF6 and its mixtures are outside the scope of this document and are covered by IEC 62271-4. Procedures to determine SF6 leakages are described in IEC 60068-2-17.
For the purposes of this document, the complementary gases used in SF6 mixtures will be limited to N2 or CF4.
This third edition cancels and replaces the second edition, published in 2004. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
• specifications for the re-use of SF6 have been confirmed;
• specifications for the re-use of SF6 mixtures, namely SF6/N2 and SF6/CF4 mixtures are included;
• as a result of a new repartition of annexes in IEC 60376, IEC 60480 and IEC 62271-4, this new edition now contains the following five annexes:
– Annex A: Description of methods of analysis (on-site and laboratory);
– Annex B: By–products of SF6 and its mixtures;
– Annex C: Procedure for evaluating the potential effects on health from by products of SF6 and its mixtures;
– Annex D: Reclaiming recommendations.
– Annex E: Cryogenic reclaiming of SF6;

  • Standard
    97 pages
    English and French language
    sale 15% off

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for
use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating
frequencies deviating from the supply frequency, associated with fluorescent induction lamps
as specified in IEC 62532 and IEC 62639, for high-frequency operation.
For emergency lighting operation, particular requirements for controlgear operated from a
central supply are given in Annex J. Performance requirements appropriate to the safe
operation of emergency lighting are also contained in Annex J.
Requirements for emergency lighting controlgear operating from non-centralized power
supplies are given in IEC 61347-2-7.
NOTE Performance requirements detailed in Annex J are those considered to be safety related with respect to
reliable emergency operation.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61347-2-3:2011 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition cancels and replaces the first edition published in 2000, its Amendment 1 (2004) and its Amendment 2 (2006), IEC 61347-2-4 published in 2000, IEC 61347-2-5 published in 2000 and IEC 61347-2-6 published in 2000. This second edition constitutes a technical revision. The significant revisions with respect to the first edition are:  - rectifying test conditions when dimming;  - construction requirements;   - measurement circuits and limits for HF leakage currents;  - modification of the structure to become a standard exclusively for a.c. and d.c. central supplied electronic control gear for general lighting and Annex J cover centrally- supplied emergency control gear.   This publication is to be read in conjunction with IEC 61347-1:2007. The contents of the corrigendum of September 2011 have been included in this copy.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and at an output frequency which can deviate from the supply frequency, associated with LED modules.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61800-9-2:2017 specifies energy efficiency indicators of power electronics (complete drive modules, CDM), power drive systems (PDS) and motor starters, all used for motor driven equipment. It specifies the methodology for the determination of losses of the complete drive module (CDM), the power drive system (PDS) and the motor system.
It defines IE and IES-classes, their limit values and provides test procedures for the classification of the overall losses of the motor system.
Furthermore, this document proposes a methodology for the implementation of the best energy efficiency solution of drive systems.
This depends on the architecture of the motor driven system, on the speed/load profile and on the operating points over time of the driven equipment.

  • Standard
    226 pages
    English and French language
    sale 15% off

IEC 61800-9-1:2017 specifies the general methodology to energy efficiency standardization for any extended product by using the guidance of the extended product approach (EPA).
This document specifies the methodology of determination of losses of the extended product and its sub-parts. It is applicable to motor systems operated by a motor starter or by a converter (power drive systems).

  • Standard
    61 pages
    English and French language
    sale 15% off

This part of HD 60364 deals with general requirements for isolation and switching and with the
requirements for selection and erection of the devices provided to fulfil such functions.

  • Standardization document
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of HD 60364 deals with general requirements for isolation, switching, control and monitoring and with the requirements for selection and erection of the devices provided to fulfil such functions

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use
on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.
This standard also covers lamp controlgear for lamps which are not yet standardized.
Tests dealt with in this standard are type tests. Requirements for testing individual lamp
controlgear during production are not included.
Requirements for semi-luminaires are given in IEC 60598-1:2014 (see definition 1.2.60).
Particular requirements for controlgears providing safety extra low voltage (from now on
SELV) are given in Annex L.
It can be expected that lamp control gear which comply with this standard will not compromise
safety between 90 % and 110 % of their rated supply voltage in independent use and when
operated in luminaires complying with the safety standard IEC 60598-1 and the relevant part
IEC 60598-2-xx and with lamps complying with the relevant lamp standards. Performance
requirements may require tighter limits.

  • Standard
    124 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard provides general and safety requirements for programmable
components used in products covered by IEC 61347.
The requirements of this standard are only applicable to the programmable components
(including its embedded software) in the electronic lamp controlgear. For other
electric/electronic circuits and their components in the electronic lamp controlgear, the
requirements of IEC 61347 series apply.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies performance requirements for electronic controlgear for
use on a.c. and/or d.c. supplies up to 1 000 V and/or a.c. supplies up to 1 000 V at 50 Hz or
60 Hz, associated with discharge lamps, as specified in IEC 61167, which have information
for low frequency square wave operation, where the frequency range of the low frequency is
from 70 Hz to 400 Hz.
Tests in this standard are type tests. Requirements for testing individual controlgear during
production are not included.
There are regional standards regarding the regulation of mains current harmonics and
immunity for end products like luminaires and independent controlgear. In a luminaire, the
controlgear is dominant in this respect. Controlgear, together with other components, should
comply with these standards.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for
use on d.c. or a.c. supplies up to 1 000 V (a.c. at 50 Hz or 60 Hz) and at an output frequency
which can deviate from the supply frequency, associated with LED modules.
Controlgear for LED modules specified in this standard are designed to provide constant
voltage or current at SELV or higher voltages. Deviations from the pure voltage and current
types do not exclude the gear from this standard.
The annexes of IEC 61347-1 which are applicable according to this Part 2-13 and using the
word “lamp” are understood to also comprise LED modules.
Particular requirements for SELV controlgear are given in Annex I.
Performance requirements are covered by IEC 62384.
Plug-in controlgear, being part of the luminaire, are covered as for built-in controlgear by the
additional requirements of the luminaire standard.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies particular safety requirements for starting devices (starters, other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combiation with lamps and ballasts.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of the IEC 61347 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductivetype electromagnetic controlgear for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This standard applies to complete electromagnetic controlgear and to their component parts such as reactors, transformers and capacitors. Particular requirements for thermally protected electromagnetic controlgear are given in Annex B. For certain types of discharge lamps, an ignitor is required.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61347-2-2:2011 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz and with rated output voltage 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005) and Amendment 2 (2006). The major modification for this second edition is the changeover from SELV equivalent to SELV.   This publication is to be read in conjunction with IEC 61347-1:2007.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies particular safety requirements for battery supplied electronic
controlgear for maintained and non-maintained emergency lighting purposes.
It includes specific requirements for electronic controlgear and control units for self-contained
luminaires for emergency lighting as specified by IEC 60598-2-22.
It is intended for controlgear for fluorescent lamps, but it is also applicable to other lamp types
e.g. incandescent, high pressure discharge lamps and LEDs.
This standard covers the emergency mode operation of a controlgear. For controlgear with a
combination of normal and emergency lighting operation, the normal lighting operation
aspects are covered by the appropriate part 2 of IEC 61347.
DC supplied electronic controlgear for emergency lighting may or may not include batteries.
This standard also includes operational requirements for electronic controlgear, which, in the
case of d.c. supplied electronic controlgear, are regarded as performance requirements. This
is because non-operational emergency lighting equipment presents a safety hazard. It does
not apply to d.c. supplied electronic controlgear for emergency lighting, which are intended for
connection to a centralised emergency power supply system. A centralised emergency power
system could be a central battery system.
NOTE Annex J of IEC 61347-2-3 applies to a.c., a.c./d.c. or d.c. supplied electronic controlgear for connection to
centralised emergency power supply systems that are also intended for emergency lighting operations from
a.c./d.c. supplies.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. Performance requirements are the subject of IEC 60929. Particular requirements for electronic control gear with means protection against overheating are given in Annex C. For emergency lighting operation, particular requirements for control gear operated from a central supply are given in Annex J. Performance requirements appropriate to the safe operation of emergency lighting are also contained in Annex J. Requirements for emergency lighting control gear operating from non-centralised power supplies are given in IEC 61347-2-7.

  • Corrigendum
    1 page
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. Performance requirements are the subject of IEC 60929. Particular requirements for electronic control gear with means protection against overheating are given in Annex C. For emergency lighting operation, particular requirements for control gear operated from a central supply are given in Annex J. Performance requirements appropriate to the safe operation of emergency lighting are also contained in Annex J. Requirements for emergency lighting control gear operating from non-centralised power supplies are given in IEC 61347-2-7.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amandma A1:2011 je dodatek k standardu SIST EN 61347-2-12:2006
This part of IEC 61347 specifies particular general and safety requirements for d.c. or a.c. supplied electronic ballasts. The supply comprises a.c. voltages up to 1000 V at 50 Hz/60 Hz. The type of ballast is an convertor that may contain igniting and stabilising elements for operation of a discharge lamp at d.c. or at a frequency that can deviate from the supply frequency. The lamps associated with the ballast are specified in IEC 60188 (High pressure mercury vapour lamps), IEC 60192 (Low pressure sodium vapour lamps), IEC 60662 (High pressure sodium vapour lamps), IEC 61167 (Metal halide lamps) and else for general purpose lighting. Ballasts for fluorescent lamps and for lamps for special applications like for theatre and for vehicles are excluded.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Provides alternative methods for specifying ratings for adjustable speed electrical power drive systems (PDS) and in particular their basic drive modulus (BDM).

  • Technical report
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies particular safety requirements for starting devices (starters, other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combiation with lamps and ballasts.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The contents of the corrigendum of August 2012 have been included in this copy.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61347 specifies particular general and safety requirements for d.c. or a.c. supplied electronic ballasts. The supply comprises a.c. voltages up to 1000 V at 50 Hz/60 Hz. The type of ballast is an convertor that may contain igniting and stabilising elements for operation of a discharge lamp at d.c. or at a frequency that can deviate from the supply frequency. The lamps associated with the ballast are specified in IEC 60188 (High pressure mercury vapour lamps), IEC 60192 (Low pressure sodium vapour lamps), IEC 60662 (High pressure sodium vapour lamps), IEC 61167 (Metal halide lamps) and else for general purpose lighting. Ballasts for fluorescent lamps and for lamps for special applications like for theatre and for vehicles are excluded.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This standard also covers lamp controlgear for lamps which are not yet standardized. Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included. This part 1 is to be used in conjunction with the appropriate part 2, which contains clauses to supplement or modify the corresponding clauses in part 1, to provide the relevant requirements for each type of product. This first edition of EN 61347-1, together with parts 1 to 9 of EN 61347-2, cancels and replaces EN 60920, EN 60922, EN 60924, EN 60926, EN 60928 and EN 61046, and constitute a minor revision. The relationship between the parts that make up EN 61347-2 and the IEC standards they replace is detailed as follows: EN 61347-2-1 replaces EN 60926 EN 61347-2-2 replaces EN 61046 EN 61347-2-3 replaces EN 60928 EN 61347-2-4 replaces EN 60924, Section 3 EN 61347-2-5 replaces EN 60924, Section 4 EN 61347-2-6 replaces EN 60924, Section 5 EN 61347-2-7 replaces EN 60924, Section 6 EN 61347-2-8 replaces EN 60920 EN 61347-2-9 replaces EN 60922

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in EN 60081 and 60901. This first edition of EN 61347-2-8, together with EN 61347-1, cancels and replaces the first edition of EN 60920, published in 1990, and constitutes a minor revision. This standard shall be used in conjunction with EN 61347-1. It was established on the basis of the first edition (2000) of that standard.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This first edition of IEC 61347-2-11, published in conjunction with IEC 61347-1, represents an editorial review of IEC 60920. The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This part of IEC 61347 specifies general and safety requirements for miscellaneous electronic circuits used with luminaires for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and/or d.c. supplies up to 250 V. This part does not apply to circuits or devices for which specific IEC standards are published. This first edition of IEC 61347-2-11, together with IEC 61347-1, cancels and replaces the first edition of IEC 60920, published in 1990, and constitutes a minor revision. This standard shall be used in conjunction with IEC 61347-1.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies particular safety requirements for starting devices (starters, other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combiation with lamps and ballasts.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The contents of the corrigendum of July 1987 have been included in this copy. It has the status of a horizontal standard in accordance with IEC Guide 108.

  • Standard
    15 pages
    English and French language
    sale 15% off
  • Standard – translation
    44 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This technical report is for use as a guide for electrical installations.  It explains the relationship between the time/current characteristic of protective devices and wiring, prospective short-circuit currents and maximum length of wiring and the thermal characteristics of conductors.[
]The contents of the corrigendum of October 1995 have been included in this copy.

  • Standard
    226 pages
    English and French language
    sale 15% off
  • Technical report
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Covers specifications and test methods for unused polybutenes, as delivered, intended for use as insulating liquids in electrical equipment.

  • Standardization document
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

It has the status of a horizontal standard in accordance with IEC Guide 108.

  • Standard – translation
    39 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day