Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification

This European Standard specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this standard).
NOTE 1       The elements of curtain walling have to be assigned to group 1 to 4 product depending on their design.
This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover precast concrete elements.
It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics.
This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241.
NOTE2   Construction products that can be reached or driven through by vehicles should be protected by appropriate measures such as barriers, extensible ramps, etc.

Türen, Fenster, Vorhangfassaden, Gitterelemente und Abschlüsse - Einbruchhemmung - Anforderungen und Klassifizierung

Dieses Dokument legt die Anforderungen und die Klassifizierung der einbruchhemmenden Eigenschaften von Türelementen, Fenstern, Vorhangfassaden, Gitterelementen und Abschlüssen fest. Es gilt für die folgenden Öffnungsarten: Drehen, Kippen, Falten, Drehkippen, Schwingen, Schieben (horizontal und vertikal), Schwenken (horizontal und vertikal) und Rollen sowie für nicht öffenbare Konstruktionen. Das Dokument behandelt außerdem auch Produkte, die Elemente wie beispielsweise Briefklappen oder Lüftungsgitter enthalten. Es legt Anforderungen an die Einbruchhemmung eines Bauproduktes fest (entsprechend 3.1 der vorliegenden Norm).
ANMERKUNG 1   Die Elemente einer Vorhangfassade werden den Produkten der Gruppe 1 bis 4 je nach Konstruktion zugeordnet.
Mechatronische und elektronische Sicherheitssysteme sind in Anhang E aufgeführt.
Dieses Dokument behandelt nicht direkt die Widerstandsfähigkeit von Schlössern und Schließzylindern gegen Angriffe mit Sperrwerkzeugen (Picking). Außerdem behandelt es keine Betonfertigteile. Beschläge sind ein Bestandteil auf den Produkten und können als solche nicht nach dieser Norm klassifiziert werden.
Dieses Dokument gilt nicht für Türen, Tore und Schranken, die für den Einbau in Bereichen für den Zugang von Personen dienen und die hauptsächlich für einen sicheren Zugang für Güter und von Personen geführten Fahrzeugen in industriellen, gewerblichen und Wohnbereichen gedacht sind, welche in den Anwendungsbereich von EN 13241 fallen.
ANMERKUNG 2   Es ist wichtig, dass Bauprodukte, die durch Kraftfahrzeuge erreicht oder durchfahren werden können, durch geeignete Maßnahmen, wie Sperren, ausfahrbare Rampen usw., geschützt werden.

Blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures - Résistance à l'effraction - Prescriptions et classification

Le présent document fixe les exigences et les systèmes de classification relatifs aux caractéristiques de résistance à l’effraction des blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures. Il s’applique aux constructions fixes et aux systèmes ouvrants suivants : battant, oscillant, pliant, oscillo battant, à gonds haut ou bas, coulissant (horizontalement et verticalement), pivotant (horizontalement et verticalement) et à enroulement. Il couvre également les produits comportant des éléments tels que des fentes à lettres ou des grilles de ventilation. Il spécifie les exigences relatives à la résistance à l’effraction d’un produit de construction (telle que définie en 3.1 dans la présente norme).
NOTE 1   Les éléments de façade rideau sont affectés au produit des groupes 1 à 4 en fonction de leur conception.
Des systèmes de sécurité mécatroniques et électroniques sont inclus dans l’Annexe E.
Le présent document ne traite pas directement de la résistance aux ouvertures fines des serrures et des cylindres. Il ne s’applique pas non plus aux éléments préfabriqués en béton. La quincaillerie est un composant des produits et ne peut pas être classée comme telle conformément à la présente norme.
Le présent document ne s’applique pas aux portes, portails et barrières, destinés à être installés dans des zones accessibles aux personnes et dont l’utilisation principale prévue est de permettre l’accès sécurisé de marchandises et de véhicules accompagnés ou conduits par des personnes, dans des locaux industriels et commerciaux ou des garages dans les zones d’habitation, tel que traité par l’EN 13241.
NOTE 2   Il est important que les produits de construction qui sont accessibles ou peuvent être empruntés par des véhicules, soient protégés par des moyens appropriés tels que des barrières, rampes déployables, etc.

Vrata, okna, obešene fasade, mreže in polkna - Protivlomna odpornost - Zahteve in klasifikacija

General Information

Status
Published
Public Enquiry End Date
19-Jul-2019
Publication Date
17-Jun-2021
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Jun-2021
Due Date
19-Aug-2021
Completion Date
18-Jun-2021

Relations

Buy Standard

Standard
EN 1627:2021
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 1627:2019 - BARVE
English language
57 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 1627:2021
01-september-2021
Nadomešča:
SIST EN 1627:2011
Vrata, okna, obešene fasade, mreže in polkna - Protivlomna odpornost - Zahteve in
klasifikacija
Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance -
Requirements and classification
Türen, Fenster, Vorhangfassaden, Gitterelemente und Abschlüsse - Einbruchhemmung -
Anforderungen und Klassifizierung
Blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures - Résistance à
l'effraction - Prescriptions et classification
Ta slovenski standard je istoveten z: EN 1627:2021
ICS:
13.310 Varstvo pred kriminalom Protection against crime
91.060.50 Vrata in okna Doors and windows
SIST EN 1627:2021 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 1627:2021

---------------------- Page: 2 ----------------------
SIST EN 1627:2021


EN 1627
EUROPEAN STANDARD

NORME EUROPÉENNE

June 2021
EUROPÄISCHE NORM
ICS 13.310; 91.060.50 Supersedes EN 1627:2011
English Version

Pedestrian doorsets, windows, curtain walling, grilles and
shutters - Burglar resistance - Requirements and
classification
Blocs-portes pour piétons, fenêtres, façades rideaux, Türen, Fenster, Vorhangfassaden, Gitterelemente und
grilles et fermetures - Résistance à l'effraction - Abschlüsse - Einbruchhemmung - Anforderungen und
Prescriptions et classification Klassifizierung
This European Standard was approved by CEN on 19 March 2021.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 1627:2021 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Resistance classification . 7
5 Glazing . 8
6 Building hardware . 8
6.1 General . 8
6.2 Key related security . 8
6.2.1 Requirements . 8
6.2.2 Application to windows . 9
6.3 Attack related security . 10
6.4 Building hardware assessment according to their appropriate standard . 10
6.5 Assessment of building hardware not complying with Table 3 requirements . 12
6.5.1 General . 12
6.5.2 Additional test and tool set for building hardware not complying with Table 3 . 13
7 Mechanical strength . 20
7.1 Static loading . 20
7.2 Dynamic loading in resistance classes 1, 2 and 3 . 23
8 Manual burglary attempts . 23
8.1 General . 23
8.2 Non-key operated lockable hardware . 24
9 Classification report . 24
10 Installation . 24
11 Test specimens . 24
Annex A (informative) Recommendations for the contents of the manufacturer's
installation instructions . 25
Annex B (informative) Resistance classes – Classification according to EN 1627 . 26
Annex C (normative) Field of application . 28
Annex D (normative) Procedure for testing and classification . 34
Annex E (informative) Marking . 36

2

---------------------- Page: 4 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
European foreword
This document (EN 1627:2021) has been prepared by Technical Committee CEN/TC 33 “Doors, windows,
shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by December 2021, and conflicting national standards shall
be withdrawn at the latest by December 2021.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 1627:2011.
Significant changes in this revision are:
a) Normative references updated;
b) Scope includes electromechanical building hardware products;
c) Clarification of the number of resistance classes (RC 1 / RC 1N);
d) Clause 6 - Building hardware re-written;
e) New subclause 8.2 – Non-key operated lockable hardware;
f) Annex B deleted;
g) Annex C rewritten and updated;
h) New informative Annex E - Marking added;
This document is one of a series of standards for burglar resistant pedestrian doorsets, windows, curtain
walling, grilles and shutters. The other standards in the series are:
— EN 1628:2021, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance under static loading;
— EN 1629:2021, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance under dynamic loading;
— EN 1630:2021, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance to manual burglary attempts.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
3

---------------------- Page: 5 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
1 Scope
This document specifies requirements and classification systems for burglar resistant characteristics of
pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following
opening functions: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and
vertically), pivoted (horizontally and vertically), projecting and rolling as well as non-openable
constructions. It also covers products that include items such as letter plates or ventilation grilles. It
specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this
document).
NOTE 1 The elements of curtain walling will be assigned to group 1 to 4 product depending on their design.
This document does not directly cover the resistance of locks and cylinders to attack with picking tools.
Building hardware are components of the above mentioned products and cannot be classified as such
according to this document.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for
installation in areas in the reach of persons, and for which the main intended uses are giving safe access
for goods and vehicles accompanied or driven by persons in industrial, commercial or residential
premises, as covered by EN 13241:2003+A2:2016.
NOTE 2 It is important that construction products that can be reached or driven through by vehicles are
protected by appropriate measures such as barriers, extensible ramps, etc.
The requirements to an electronic security system (e.g. access control system) to control
electromechanical locks and strikes according to EN 14846:2008 are not in the scope of this document.
NOTE 3 Locks and striking plates according to EN 14846:2008 needs an access control system for authorized
and secure access (comparable to a lock cylinder). The transmission of the signal between the lock and the access
control system (e.g. wiring) needs also consideration. (The signal is transmitted in encrypted form or is not
accessible during the manual attack attempt.) Upcoming revisions of this document might include such a reference.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 356:1999, Glass in building — Security glazing — Testing and classification of resistance against
manual attack
EN 1303:2015, Building hardware — Cylinders for locks — Requirements and test methods
EN 1628:2021, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance —
Test method for the determination of resistance under static loading
EN 1629:2021, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance —
Test method for the determination of resistance under dynamic loading
EN 1630:2021, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance —
Test method for the determination of resistance to manual burglary attempts
EN 1906:2012, Building hardware — Lever handles and knob furniture — Requirements and test methods
EN 12209:2016, Building hardware — Mechanically operated locks and locking plates — Requirements
and test methods
4

---------------------- Page: 6 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
EN 12216:2018, Shutters, external blinds, internal blinds — Terminology, glossary and definitions
EN 12519:2018, Windows and pedestrian doors — Terminology
EN 13119:2016, Curtain walling — Terminology
EN 13126-3:2011, Building hardware — Hardware for windows and door-height windows — Requirements
and test methods — Part 3: Handles, primarily for Tilt&Turn, Tilt-First and Turn-Only hardware
EN 13241:2003+A2:2016, Industrial, commercial, garage doors and gates — Product standard,
performance characteristics
EN 14846:2008, Building hardware — Locks and latches — Electromechanically operated locks and
striking plates — Requirements and test methods
EN 15684:2020, Building hardware — Mechatronic cylinders — Requirements and test methods
1
EN 15685:—, Building hardware — Multipoint locks, latches and locking plates — Characteristics and test
methods
EN 16867:2020, Building hardware — Mechatronic door furniture — Requirements and test methods
EN ISO 6508-1:2016, Metallic materials — Rockwell hardness test — Part 1: Test method (ISO 6508-
1:2016)
EN ISO 80000-1:2013, Quantities and units — Part 1: General (ISO 80000-1:2009+Cor 1:2011)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 12519:2018, EN 12216:2018,
EN 13119:2016, EN ISO 80000-1:2013 and the following apply.
3.1
burglar resistance
property of pedestrian doorsets, windows, curtain walling, grilles and shutters to resist attempts of
forced entry using physical force and with the aid of predefined tools into the protected room or area
3.2
burglar resistant product
complete, functioning element that, when built in and fastened or fastened and secured, has the function
of resisting forced entry through the application of physical force assisted by predefined tools

1 Under preparation. Stage at the time of publication: prEN 15685:2019.
5

---------------------- Page: 7 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
3.3
Group 1 product
product that has a solid and rigid leaf and/or opening element
Note 1 to entry: If the product incorporates an opening element, the principal movement to open is turning of the
element.
Note 2 to entry: Examples of Group 1 products are hinged or pivoted windows and doorsets or fixed windows.
Non-openable are also defined as a Group 1 product.
3.4
Group 2 product
product that has a solid and rigid leaf or opening element and the principal movement to open is sliding
Note 1 to entry: Non-openable parts of these products are subject to the same tests as the Group 1 products.
Note 2 to entry: Examples of Group 2 products are sliding doorsets and sliding windows.
3.5
Group 3 product
product that has a leaf or opening element constructed from a number of rigid elements joined together
such that the elements may move relative to each other
Note 1 to entry: An example of a Group 3 product is a roller shutter.
3.6
Group 4 product
product with one or more openings (excluding letter plates) through which gap gauge B (25 mm) can
pass
Note 1 to entry: An example of a Group 4 product is a grille or a roller grille.
3.7
resistance class RC
level of resistance that the product provides against burglary attempts
3.8
attack side
side of the test specimen defined by the applicant as the side exposed to attack
3.9
non-attack side
side of the test specimen defined by the applicant as the side not exposed to attack
3.10
roller shutter
shutter where the curtain is retracted by rolling and consists of interconnected horizontal laths, that can
be tilted or not, which run in side channels
[SOURCE: EN 12216:2018 3.5.2]
6

---------------------- Page: 8 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
3.11
roller grille
component that can be moved vertically or horizontally in front of the opening to be secured and that can
also be removed
Note 1 to entry: The individual grille bars are movably interconnected with each other. The grille curtain travels
over a roller in order to open.
3.12
resistance time
working time of the test person carrying out the manual burglary test
Note 1 to entry: The resistance time includes times of less than 5 s each for tool changes, e.g. exchanging a
screwdriver for a crowbar.
3.13
infilling
glazing or panel of any material or combination of materials which are used to fill an aperture in a window
or doorset that can be replaced, and which are typically retained by glazing beads
3.14
non-key operated lockable hardware
component, which can be locked and/or unlocked without the use of a key
4 Resistance classification
Each construction product conforming to this document shall be classified according to one of eight
resistance classes, depending on the level of burglar resistance offered by the product.
NOTE The resistance classes correspond to known methods of attack currently used by burglars as described
in Annex B, Table B.1.
A system or family of products shall be classified using the approach described in Annex C.
The test specimen shall be in the secured condition defined by the manufacturer.
A product offering burglar resistance at more than one secured condition can be tested, assessed and
classified at each condition.
In the documentation accompanying the product, the resistance class shall be given as per the following
examples (see Annex E):
— Burglar resistant window EN 1627 RC 1 N;
— Burglar resistant window EN 1627 RC 3;
— Burglar resistant door EN 1627 RC 2.
The procedure for testing and classification shall be carried out as described in Annex D.
For the purpose of historic data, products covered by the scope of this document and classified under
EN 1627:2011 or EN 1627:1999, meet the same classes of this document.
7

---------------------- Page: 9 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
5 Glazing
The glazing shall meet the minimum requirements in Table 1. When several panes of glass are used in a
product, e.g. insulating glass units, then at least one pane shall meet the resistance class as shown in
Table 1. On a product classified to this document the pane used in the test can be replaced with a glazing
with the same or higher resistance class if the retention system remains identical to that tested. For
RC1/RC 1N and RC 2N the pane used in the test can also be replaced with another glazing, if the retention
system remains identical.
Table 1 — Minimum requirements for glazing
Resistance class for
Resistance class of pane according to EN 356:1999
product
RC 1 P2A
a
RC 1 N
No requirements
a
RC 2 N
No requirements
RC 2 P4 A
RC 3 P5 A
RC 4 P6 B
RC 5 P7 B
RC 6 P8 B
a
National provision may be followed.
On elements equipped with emergency exit devices or panic exit devices, the glazing or the infilling shall
prohibit operating the device to gain an accessible opening by penetrating the infilling with the relevant
tools. This vulnerability shall be examined according to EN 1630:2021, 6.3.1.
6 Building hardware
6.1 General
The requirements for building hardware fitted on pedestrian doorsets, windows, curtain walling, grilles
and shutters subject to this document are detailed in 6.2 to 6.5.
6.2 Key related security
6.2.1 Requirements
For all resistance classes, building hardware components lockable with a key shall fulfil key related
security requirements according to Table 2.
8

---------------------- Page: 10 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
Table 2 — Key related security
Building Requirement RC 1 / RC 2 / RC 3 RC 4 RC 5 RC 6
hardware RC 1 N RC 2N
standard
EN 1303:2015
Digit 7 4 4 4 6 6 6
cylinder for lock
a b
E E F F F
EN 15684:2020 Digit 5 E
Mechatronic or
A B B C D D
cylinder a
Digit 6
EN 12209:2016 Digit 8 key
Mechanical identification B B B D E E
lockcase (lever lock)
1
EN 15685: —
Digit 8 Mechanical
Multipoint locks B B B D E E
keys
(under process)
Digit 7 – 2nd part
EN 13126-3:2011
of digit 7
Key operated
c c
extension for 2/2 2/3 2/3 2/3
2 /2 2 /2
lockable window
locking
handle
mechanism
EN 16867:2020
Digit 7 A B B D D D
Mechatronic door
furniture
a
The specified grades may alternatively be achieved by the mechanical (digit 5) or electronic (digit 6)
key related security. Mechatronic cylinders do not need to have a mechanical lockwork (EN 15684:2020,
digit 5, Grade A). In this case, grade A in digit 6 of EN 15684:2020 fulfils the requirement.
b
Mechatronic cylinder with mechanical codes shall have a minimum number of 6 movable detainers
(digit 7 level 5 of EN 1303:2015).
c
Grade 1 (1st part of digit 7) only if two or more handles are used on a single sash.

6.2.2 Application to windows
6.2.2.1 General
For handles on windows it may be possible to actuate the handle indirectly from the attack side by a
displacement of the transmission rod of the building hardware, e.g. by initiating a movement on one of
the locking cams. Therefore, either lockable window handles in accordance with the requirements of
Table 2 or alternatively other building hardware components to provide protection against this kind of
attack shall be used.
6.2.2.2 Lockable window handles
In general, the lock case area on the gear of the window hardware in which the lockable window handle
engages shall be protected against drilling. When using lockable window handles with a (square) spindle
or geared lockable window handles with a connector or fork as connecting element, it shall be prevented
that the connecting element is drilled out so that the connecting rod of the hardware is no longer secured
against displacement by the handle.
9

---------------------- Page: 11 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
This shall be realized by using a drill protected lock case or a drill protected layer or the overlapping by
drill protected furniture on the attack side. The minimum surface hardness for the drill protected lock
case or a drill protected layer shall be 60 HRC according to EN ISO 6508-1 with a hardness depth of 0,3
to 0,5 mm as a rule. The verification can also be carried out by a hand-held drilling test with drilling tools
from tool set A.3 according to EN 1630:2021 with a resistance time of at least 3 minutes.
— Key operated lockable window handles: In the case of using window handles with a key operated
locking mechanism the requirements of Table 2 are applicable to the window handle opposite to the
attack side (digit 7: 2/2 or 2/3 in accordance with EN 13126-3:2011).
— Non-key operated lockable window handles: In the case of using window handles with a non-key
operated locking mechanism (for example PTO 'push to open'), the requirements in accordance with
EN 13126-3:2011, digit 7: 2/1 shall be met.
For non-key operated lockable window handles a test of the window handle shall be carried out in
accordance with Clause 8 of this document.
6.2.2.3 Non-lockable window handles
In the case of using window handles without any locking mechanism, other components with an
appropriate locking function should be used. In this case generally a test in accordance with Clause 8 of
this document shall be carried out.
For RC 1 / RC 1 N additionally a test in accordance with EN 1628:2021, Annex C of shall be carried out if
applicable.
6.3 Attack related security
Building hardware fitted on pedestrian doorsets, windows, curtain walling, grilles and shutters subject
to this document shall either:
— meet the requirements in Table 3 (see under 6.4); or
— be tested in accordance with 6.5.
Either of the above options may be requested by of the applicant.
In the case of testing in accordance with Clause 6.5 the retention of the hardware shall be tested according
to EN 1630:2021 for RC 2/ RC 2N up to RC 6.
6.4 Building hardware assessment according to their appropriate standard
Building hardware shall fulfil the requirements of Table 3, according to their appropriate specific
standard.
The requirements of Table 3 are valid for those parts of the building hardware that are on the attack side
of the pedestrian doorsets, windows, curtain walling, grilles and shutters defined by the applicant.
During the manual burglary test according to EN 1630:2021, resistance classes RC5 and RC6, the building
hardware according to Table 3 shall be included as attack areas.
10

---------------------- Page: 12 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
Table 3 — Attack related security
Building hardware Requirement RC 1 / RC 2 N RC 2 RC 3 RC 4 RC 5 RC 6
standard RC 1 N
EN 1303:2015 test according to
Digit 8 A C C C D
cylinder for lock EN 1630:2021
EN 1303:2015 Digit 8
test according to
cylinder for locks in of A A A A B
EN 1630:2021
combination with EN 1303:2015
EN 1906:2012 lever
Digit 7
handle with
test according to
of 1 2 2 3 4
cylinder and plug
EN 1630:2021
EN 1906:2012
pulling protection
Digit 8
EN 1303:2015
test according to
of A A A A B
cylinder for locks in
EN 1630:2021
EN 1303:2015
combination with
Digit 8 of test according to
EN 16867:2020
0 1 1 2 3
EN 16867:2020 EN 1630:2021
lever handle with
cylinder and plug
Digit 9 of test according to
1 2 2 3 4
pulling protection
EN 16867:2020 EN 1630:2021
EN 15684:2020,
2 and test according
Mechatronic Digit 8 1 1 1 1 2
to EN 1630:2021
cylinders
EN 15684:2020 Digit 8
2 and test according
mechatronic of
A A A A B
to EN 1630:2021
cylinder in
EN 15684:2020
combination with
EN 1906:2012 lever
Digit 7
test according to
handle with
of 1 2 2 3 4
EN 1630:2021
cylinder and plug
EN 1906:2012
pulling protection
EN 1906:2012
test according to
Digit 7 Security 1 1 2 3 4
Lever handles and
EN 1630:2021
knob furniture
EN 12209:2016
Mechanically
operated locks and
locking plates or
1
test according to
EN 15685:—
a
Digit 7 3 3 3 4
7
EN 1630:2021
Multipoint locks,
latches and locking
plates:
Classification based
on one point
11

---------------------- Page: 13 ----------------------
SIST EN 1627:2021
EN 1627:2021 (E)
Building hardware Requirement RC 1 / RC 2 N RC 2 RC 3 RC 4 RC 5 RC 6
standard RC 1 N
test according to
1
EN 15685:—
Digit 7 2 3 3 3 5
EN 1630:2021
Multipoint locks,
latches and locking
Digit 9
plates: Classification
Security for test according to
2 3 3 3 5
based on more than
anti-separation EN 1630:2021
one points
point
EN 14846:2008, Digit 7 test according to
b
3 3 3 4
7
Electromechanically Security EN 1630:2021
operated locks and
Digit 9 2 2 2 2 3 3
striking plate
Digit 7
1st part of digit c
2
EN 13126-3:2011
7: grade for c c
2 /2 2 /2 /2 2/2 2/3 2/3
window handle
resistance
c c 2 2/1 2/1 2/1
2 /1 2 /1
(lockable)
against
c
/1
twisting-off
and forcing-off”
test according to
Digit 8 0 1 1 2 3
EN 1630:2021
EN 16867:2020
Digit 9
Mechatronic door
test according to
Security
furniture
1 2 2 3 4
EN 1630:2021
related to
EN 1906:2012
a
A lock with security class 6 (digit 7) may be used if the drill resistance required in class 7 is provided by the door
construction.
b
A lock with security class 4 (digit 7) may be used if the drill resistance required in class 7 is provided by the door
construction.
c
Grade 1 (1st part of digit 7) only if two or more handles are used on a single sash.
6.5 Assessment of building hardware not complying with Table 3 requirements
6.5.1 General
When building hardware does not comply with the requirements of Table 3, an assessment of the building
hardware shall be made on the complete test specimen for RC 2/RC 2 N up to RC 4.
— The objective of the tests will be to assess the performance of the building hardware only for the
characteristics as required in Table 3;
— Test of the building hardware itself will be carried out with that component fitted on the complete
building element;
— The failure requirement will be “accessible opening” of the buildi
...

SLOVENSKI STANDARD
oSIST prEN 1627:2019
01-julij-2019
Vrata, okna, obešene fasade, mreže in polkna - Protivlomna odpornost - Zahteve in
klasifikacija
Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance -
Requirements and classification
Türen, Fenster, Vorhangfassaden, Gitterelemente und Abschlüsse - Einbruchhemmung -
Anforderungen und Klassifizierung
Blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures - Résistance à
l'effraction - Exigences et classification
Ta slovenski standard je istoveten z: prEN 1627
ICS:
13.310 Varstvo pred kriminalom Protection against crime
91.060.50 Vrata in okna Doors and windows
oSIST prEN 1627:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 1627:2019

---------------------- Page: 2 ----------------------
oSIST prEN 1627:2019


DRAFT
EUROPEAN STANDARD
prEN 1627
NORME EUROPÉENNE

EUROPÄISCHE NORM

May 2019
ICS 13.310; 91.060.50 Will supersede EN 1627:2011
English Version

Pedestrian doorsets, windows, curtain walling, grilles and
shutters - Burglar resistance - Requirements and
classification
Blocs-portes pour piétons, fenêtres, façades rideaux, Türen, Fenster, Vorhangfassaden, Gitterelemente und
grilles et fermetures - Résistance à l'effraction - Abschlüsse - Einbruchhemmung - Anforderungen und
Prescriptions et classification Klassifizierung
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 33.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 1627:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 1627:2019
prEN 1627:2019 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Resistance classification . 7
5 Glazed infillings . 8
6 Building hardware . 9
6.1 General . 9
6.2 Key related security . 9
6.2.1 Requirements . 9
6.2.2 Application to windows . 9
6.3 Attack related security . 10
6.4 Hardware assessment according to their appropriate standard . 10
6.5 Assessment of hardware not fulfilling prEN 1627:2019, Table 3 requirements . 12
6.5.1 General . 12
6.5.2 Additional test and tool set for hardware not complying with Table 3 . 12
7 Mechanical strength . 21
7.1 Static loading . 21
7.2 Dynamic loading in resistance classes 1, 2 and 3 . 23
8 Manual burglary attempts . 24
8.1 General . 24
8.2 Non key operated hardware . 24
9 Classification report . 25
10 Installation . 25
11 Test specimens . 25
12 Marking . 26
Annex A (informative) Recommendations for the contents of the manufacturer's installation
instructions . 27
Annex B (informative) Resistance classes – Classification according to EN 1627 . 28
B.1 Introduction . 28
B.2 Resistance classes 1 to 3 . 28
B.3 Resistance classes 4 to 6 . 28
Annex C (normative) Field of application. 30
C.1 Dimensions . 30
C.2 Exchange of hardware elements . 32
C.3 Other modifications . 33
Annex D (normative) Procedure for testing and classification . 34
2

---------------------- Page: 4 ----------------------
oSIST prEN 1627:2019
prEN 1627: 2019 (E)
Annex E (normative) Mechatronic and electronic security systems. 36
E.1 Terms and definitions . 36
E.2 Introduction. 37
E.3 Electronic Security system . 38
E.4 Resistance grade based on presumptive modus operandi . 38
E.5 Requirements of electronic security . 39
E.6 Test methods - procedures . 50
Bibliography . 57

3

---------------------- Page: 5 ----------------------
oSIST prEN 1627:2019
prEN 1627:2019 (E)
European foreword
This document (prEN 1627:2019) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 1627:2011.
Significant changes in this revision are:
a) Normative references updated;
b) Scope includes electromechanical hardware products;
c) Clause 6 - Building hardware re-written;
d) New subclause 8.2 – Non-lockable hardware;
e) Clause 12 - Marking added;
f) Annex B deleted;
g) Annex E - Mechatronic and electronic security systems added.
This document is one of a series of standards for burglar resistant pedestrian doorsets, windows, curtain
walling, grilles and shutters. The other standards in the series are:
— prEN 1628:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance under static loading;
— prEN 1629:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance under dynamic loading;
— prEN 1630:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance to manual burglary attempts.
4

---------------------- Page: 6 ----------------------
oSIST prEN 1627:2019
prEN 1627: 2019 (E)
1 Scope
This document specifies requirements and classification systems for burglar resistant characteristics of
pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means
of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically),
pivoted (horizontally and vertically) and rolling as well as fixed constructions. It also covers products
that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar
resistance of a construction product (as defined in 3.1 of this standard).
NOTE 1 The elements of curtain walling will be assigned to group 1 to 4 product depending on their design.
Mechatronic and electronic security systems are included in Annex E.
This document does not directly cover the resistance of locks and cylinders to attack with picking tools.
It also does not cover precast concrete elements. Hardware is a component on the products and cannot
be classified as such according to this standard.
This document does not apply to doors, gates and barriers, intended for installation in areas in the reach
of persons, and for which the main intended uses are giving safe access for goods and vehicles
accompanied or driven by persons in industrial, commercial or residential premises, as covered by
EN 13241.
NOTE 2 It is important that construction products that can be reached or driven through by vehicles are
protected by appropriate measures such as barriers, extensible ramps, etc.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 356:1999, Glass in building — Security glazing — Testing and classification of resistance against
manual attack
EN 1303:2015, Building hardware — Cylinders for locks — Requirements and test methods
prEN 1628:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance
— Test method for the determination of resistance under static loading
prEN 1629:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance
— Test method for the determination of resistance under dynamic loading
prEN 1630:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance
— Test method for the determination of resistance to manual burglary attempts
EN 1906:2012, Building hardware — Lever handles and knob furniture — Requirements and test methods
EN 12209:2016, Building hardware —Mechanically operated locks and locking plates — Requirements and
test methods
EN 12519:2018, Windows and pedestrian doors — Terminology
EN 13126-3:2011, Building hardware — Hardware for windows and door-height windows - Requirements
and test methods — Part 3: Handles, primarily for Tilt&Turn, Tilt-First and Turn-Only hardware
EN 14846:2008, Building hardware — Locks and latches — Electromechanically operated locks and
striking plates - Requirements and test methods
5

---------------------- Page: 7 ----------------------
oSIST prEN 1627:2019
prEN 1627:2019 (E)
EN 15684:2012, Building hardware - Mechatronic cylinders — Requirements and test methods
1)
, Building hardware — Mechanically operated locks and locking plates — Requirements and
prEN 15685
test methods
EN ISO 80000-1:2013, Quantities and units — Part 1: General (ISO 80000-1:2009+Cor 1:2011)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 12519:2018 and
EN ISO 80000-1:2013 and the following apply.
3.1
burglar resistance
property of pedestrian doorsets, windows, curtain walling, grilles and shutters to resist attempts at
forced entry using physical force and with the aid of predefined tools into the protected room or area
3.2
burglar resistant product
complete, functioning element that, when built in and fastened or fastened and secured, has the function
of resisting forced entry through the application of physical force assisted by predefined tools
3.3
Group 1 product
product that has a solid and rigid leaf and/or opening element
Note 1 to entry: If the product incorporates an opening element, the principal movement to open is turning of the
element.
Note 2 to entry: Examples of Group 1 products are hinged or pivoted windows and doorsets or fixed windows.
Fixed constructions are also defined as a Group 1 product.
3.4
Group 2 product
product that has a solid and rigid leaf or opening element and the principal movement to open is sliding
Note 1 to entry: Fixed elements of these products are tested in accordance with Group 1 products.
Note 2 to entry: Examples of Group 2 products are sliding doorsets and sliding windows.
3.5
Group 3 product
product that has a leaf or opening element constructed from a number of rigid elements joined together
such that the elements may move relative to each other
Note 1 to entry: An example of a Group 3 product is a roller shutter.
3.6
Group 4 product
product with one or more openings (excluding letter plates) through which gap gauge B (25 mm) can
pass

1) Under preparation.
6

---------------------- Page: 8 ----------------------
oSIST prEN 1627:2019
prEN 1627: 2019 (E)
Note 1 to entry: An example of a Group 4 product is a grille.
3.7
resistance class
RC
level of resistance that the product provides against burglary attempts
3.8
attack side
side of the test specimen defined by the applicant as the side exposed to attack
3.9
non-attack side
side of the test specimen defined by the applicant as the side not exposed to attack
3.10
roller shutter
shutter, the curtain of which consists of movable, interconnected rigid elements, and travels over a roller
in order to open/close
3.11
roller grille
component that can be moved vertically or horizontally in front of the opening to be secured and that can
also be removed
Note 1 to entry: The individual grille bars are movably interconnected with each other. The grille curtain travels
over a roller in order to open.
3.12
closed condition
condition defined and described by the manufacturer or applicant in which the tested element meets the
burglar resistant requirements
Note 1 to entry: EN 12519:2018 defines closed, fastened, latched, locked and secured.
3.14
resistance time
working time of the test person carrying out the manual burglary test
Note 1 to entry: The resistance time includes times of less than 5 s each for tool changes, e.g. exchanging a
screwdriver for a crowbar.
3.15
infilling
glazing or panel of any material or combination of materials which are used to fill an aperture in a window
or doorset that can be replaced, and which are typically retained by glazing beads
4 Resistance classification
Each construction product conforming to this standard shall be classified according to one of seven
resistance classes, depending on the level of burglar resistance offered by the product.
NOTE The resistance classes correspond to known methods of attack currently used by burglars as described
in Annex B, Table B.1.
7

---------------------- Page: 9 ----------------------
oSIST prEN 1627:2019
prEN 1627:2019 (E)
A system or family of products shall be classified using the approach described in Annex C.
The test specimen shall be in the closed conditions defined by the manufacturer.
A product offering burglar resistance at more than one closed condition can be tested, assessed and
classified at each condition.
In the documentation accompanying the product, the resistance class shall be given as per the following
examples:
— Burglar resistant window EN 1627 RC 1 N
— Burglar resistant window EN 1627 RC 3
— Burglar resistant door EN 1627 RC 2
The procedure for testing and classification shall be carried out as described in Annex D.
For the purpose of historic data, products classified under prEN 1627:2019 are assumed to meet the same
classes of this standard.
5 Glazed infillings
The glazing infilling shall meet the minimum requirements in Table 1. When several panes of glass are
used in a product, e.g. insulating glass units, then at least one pane shall meet the resistance class as
shown in Table 1. On a product classified to prEN 1627, the pane can be replaced with the same or higher
resistance class of glazed infill if the retention system remains identical to that tested.
Table 1 — Minimum requirements for glazed infilling
Resistance class for
Resistance class of pane according to EN 356:1999
product
a
RC 1 N No requirements
a
RC 2 N No requirements
RC 2 P4 A
RC 3 P5 A
RC 4 P6 B
RC 5 P7 B
RC 6 P8 B
a
National provision may be followed.
NOTE 1 The use of furniture that requires a removable key or tool to effect unlocking might be required when
using glazing with a resistance class lower than P4A.
On elements equipped with emergency exit devices or panic exit devices, the glazing or the infilling shall
prohibit operating the device to gain an accessible opening by penetrating the infilling with the relevant
tools. This vulnerability shall be examined according to prEN 1630:2019, 6.3.1.
NOTE 2 Glazing according to EN 356:1999 with special or reinforced inlays can be necessary.
8

---------------------- Page: 10 ----------------------
oSIST prEN 1627:2019
prEN 1627: 2019 (E)
6 Building hardware
6.1 General
Performance evaluation of hardware fitted on pedestrian door sets, windows, curtain walling, grilles and
shutters subject to this standard shall be carried out according to the rules defined in this Clause 6.
6.2 Key related security
6.2.1 Requirements
For all resistance classes, hardware components lockable with a key shall fulfil key related security
requirements according to Table 2.
Table 2 — Key related security
Hardware Requirement RC 1 RC 2 RC 3 RC 4 RC 5 RC 6
component N
standard
EN 1303:2015
Digit 7 4 4 5 6 6 6
cylinder for lock
a
b
EN 15684:2012 Digit 5
E E E F F F
Mechatronic or
D b
a E E F F F
cylinder Digit 6
EN 12209:2016 Digit 8 key
Mechanical identification B B B D E E
lockcase (lever lock)
prEN 15685
Digit 8 Mechanical
Multipoint locks B B B D E E
keys
(under process)
EN 14846:2008        Digit 11
B B B D E E
(under revision) (EN 12209:2016)
nd
Digit 7 – 2 part
EN 13126-3:2011
of digit 7
Key operated
c c
extension for 2 /2 2 /2 2/2 2/3 2/3 2/3
lockable window
locking
handle
mechanism
a
 The specified grades may alternatively be achieved by the mechanical (digit 5) or electronic (digit
6) key related security. Mechatronic cylinders do not need to have a mechanical lockwork
(EN 15684:2012, digit 5, Grade A). In this case, grade A in digit 6 of EN 15684:2012 fulfils the
requirement.
b
 Mechatronic cylinder with mechanical codes shall have a minimum number of 6 movable detainers
(digit 7 level 5 of EN 1303:2015).
c
 Grade 1 only if two or more handles are used on a single sash.
6.2.2 Application to windows
6.2.2.1 General
For handles on windows it may be possible to actuate the handle indirectly from the attack side by
actuating the transmission rod by e. g. one of the locking cams. Therefore, either lockable window handles
9

---------------------- Page: 11 ----------------------
oSIST prEN 1627:2019
prEN 1627:2019 (E)
in accordance with the requirements of Table 2 or alternatively other hardware components to provide
protection against this kind of attack shall be used.
6.2.2.2 Lockable window handles
— Key-operated lockable window handles: In the case of using window handles with a key operated
locking mechanism the requirements of Table 2 are applicable to the window handle opposite to the
attack side (digit 7: 2/2 or 2/3 in accordance with EN 13126-3:2011).
— Non-key-operated lockable window handles: In the case of using window handles with a non-key
operated locking mechanism (for example PTO 'push to open'), the requirements in accordance with
EN 13126-3:2011, digit 7: 2/1 shall be met.
For RC 1 N: In the case of using Non-key-operated lockable window handles, a test on the window handle
in accordance with clause 8 and 6.3.1 of prEN 1630:2019 shall be carried out on the window with tool set
A1. The resistance time shall be 3 minutes and the acceptance criterion shall be 'no accessible opening'.
For RC 2/RC 2 N up to RC 6: In the case of using Non-key-operated lockable window handles, a test in
accordance with 6.3.1 of prEN 1630:2019 shall be done with the appropriate tool set and resistance time
6.2.2.3 Non-lockable window handles
In the case of using window handles without any locking mechanism, other components with an
appropriate locking function should be used. In this case generally a test in accordance with Clause 8 in
prEN 1627:2019 and subclause 6.3.1 in prEN 1630:2019 shall be carried out.
For RC 1 N: a test on the window handle in accordance with Clause 8 and 6.3.1 of prEN 1630:2019 shall
be carried out on the building element with tool set A1. The resistance time shall be 3 min and the
acceptance criterion shall be 'no accessible opening'. Additionally, a test in accordance with Annex C of
prEN 1628:2019 shall be carried out if applicable.
For RC 2/RC 2 N up to RC 6: a test in accordance with Clause 8 and 6.3.1 of prEN 1630:2019 shall be done
with the appropriate tool set and resistance time.
6.3 Attack related security
Hardware components fitted on pedestrian doorsets, windows, curtain walling, grilles and shutters
subject to this standard shall either:
— meet the requirements of prEN 1627:2019, Table 3 (see under 6.4) or
— be tested in accordance with 6.5 (prEN 1627:2019)
For RC 2/RC 2 N up to RC 6 the retention of the hardware shall be tested in accordance with
prEN 1630:2019.
6.4 Hardware assessment according to their appropriate standard
Building hardware components shall fulfil the requirements of Table 3, according to their appropriate
specific standard.
The requirements of Table 3 are valid for those parts of the hardware components that are on the attack
side of the pedestrian doorsets, windows, curtain walling, grilles and shutters defined by the applicant.
For RC 5 and RC 6 building element, building hardware components fulfilling Table 3 requirements shall
additionally be subjected to the manual attack in an attempt to open the building element in accordance
with subclause 8 of prEN 1627:2019 and prEN 1630:2019.
10

---------------------- Page: 12 ----------------------
oSIST prEN 1627:2019
prEN 1627: 2019 (E)
Table 3 — Attack related security
Hardware Requirement RC 1 RC 2 RC 2 RC 3 RC 4 RC 5 RC 6
N N
component
standard
EN 1303:2015 test according to
Digit 8 C C C C D
cylinder for lock prEN 1630:2019
Digit 8
EN 1303:2015
test according to
of A A A A B
cylinder for locks in
prEN 1630:2019
EN 1303:2015
combination with
EN 1906:2012 lever
Digit 7
test according to
handle with plug
of 2 2 2 3 4
prEN 1630:2019
protection
EN 1303:2015
EN 15684:2012,
2 and test according
Mechatronic Digit 8 1 1 1 1 2
to prEN 1630:2019
cylinders
EN 15684:2012 Digit 8
2 and test according
mechatronic of 1 2 2 2 2
to prEN 1630:2019
cylinder in EN 15684:2012
combination with
Digit 7
EN 1906:2012 lever
test according to
of 2 2 2 3 4
handle with plug
prEN 1630:2019
EN 1906:2012
protection
EN 1906:2012
test according to
Digit 7 Security 1 1 3 3 4
Lever handles and
prEN 1630:2019
knob furniture
EN 12209:2016
Mechanically
operated locks and
locking plates
test according to
prEN 15685
a
Digit 7 3 3 3 4 7
prEN 1630:2019
Multipoint locks,
latches and locking
plates:
Classification based
on one point
test according to
prEN 15685
Digit 7 2 3 3 3 5
prEN 1630:2019
Multipoint locks,
latches and locking
Digit 9
plates: Classification
Security for test according to
2 3 3 3 5
based on more than
anti-separation prEN 1630:2019
one points
point
EN 14846:2008, Digit 7 test according to
b
3 3 3 4 7
Electromechanically Security prEN 1630:2019
operated locks and
Digit 9 2 2 2 2 3 3
striking plate
11

---------------------- Page: 13 ----------------------
oSIST prEN 1627:2019
prEN 1627:2019 (E)
Hardware Requirement RC 1 RC 2 RC 2 RC 3 RC 4 RC 5 RC 6
component N N
standard
Digit 7
1st part of digit
EN13126-3:2011
7: grade for
c c c
2 /2 2 /2 2 /2 2/2 2/3 2/3
window handle
resistance
c c c
2 /1 2 /1 2 /1 2/1 2/1 2/1
(lockable)
against
twisting-off
and forcing-off"
a
 A lock with security class 6 (digit 7) may be used if the drill resistance required in class 7 is provided by the door
construction.
b
 A lock with security class 4 (digit 7) may be used if the drill resistance required in class 7 is provided by the door
construction.
c
 Grade 1 Only if two or more handles are used on a single sash.
6.5 Assessment of hardware not fulfilling prEN 1627:2019, Table 3 requirements
6.5.1 General
When hardware components do not fulfil prEN 1627:2019, Table 3, assessment of hardware capability
will be made on the complete building element for class RC 2/RC 2 N up to RC 4 building element. The
assessment is made on request of the applicant.
— The objective of the tests will be to test the performance of the hardware component only for the
characteristics as required in Table 3;
— Test of the component itself will be carried out with that component fitted on the complete building
element;
— The failure requirement will be "accessible opening" of the building element according to
prEN 1630:2019, 6.7;
— Tests will be done according to prEN 1630:2019 "test method
...

Questions, Comments and Discussion