SIST EN 61467:2009

Oznaka standarda: SIST EN 61467:2009
Koda projekta: 20704
Organizacija: SIST
Naslov (angleški): Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests (IEC 61467:2008)
Naslov (slovenski): Izolatorji za nadzemne vode – Izolatorski nizi in izolatorske verige za vode z nazivno napetostjo nad 1 000 V – Preskusi z izmeničnim oblokom (IEC 61467:2008)
Če kupite standardizacijski dokument v .pdf formatu prek spletne prodaje, vam nudimo 20% popust pri spodnji ceni brez DDV. Cenik SIST
Dokumenti
Ime Jezik Status Cena Dodaj v košarico
SIST EN 61467:2009 slovenski jezik Active SISTP-SI: 107.69 EUR
PDF
Papir
SIST EN 61467:2009 (EN) angleški jezik Active SIST-I: 85.91 EUR
PDF
Papir
SIST EN 61467:2009 (FR) francoski jezik Active SIST-I: 85.91 EUR
PDF
Papir
Tehnični odbor: IZL - Izolatorji
ICS: 29.080.10 29.240.20
Status: Objavljen
Objavljen: 01-Feb-2009
Refer. št. objave: Sporočila 2009-02
Referenčna oznaka: EN 61467:2008
Področje projekta (angleško): This International Standard applies to insulator strings and sets comprising string insulator units of ceramic material, glass or composite material for use on a.c. overhead lines and traction lines with a nominal voltage above 1 000 V and a frequency between 15 Hz and 100 Hz. This standard also applies to insulator strings or sets of similar design used in substations. This standard establishes a standard test procedure for power arc tests on insulator sets. It also establishes a standard test procedure for power arc tests on short strings. This standard does not apply to insulator sets mounted on non-metallic poles or towers. This standard cannot be directly applied to line post insulators or sets, or to insulating structures such as braced line-posts, since their mounting arrangement cannot be reproduced by the standard arrangements as described herein. However, this standard can be used as a basis for agreement for tests on such insulators and arrangements. The object of this standard is - to define the terms used, - to prescribe a standard test procedure, - to prescribe criteria to evaluate the results of the tests. Power arc tests are not an obligatory element of line insulator specifications. The standard test procedures and the evaluation criteria described in this standard are intended to provide testing guidance when power arc tests are felt to be necessary. It is not the object of this standard to introduce a general obligation to execute these tests.

Najbolje prodajani standardi