Biological systems for testing sterilizers and sterilization processes - Part 8: Particular requirements for self-contained biological indicator systems for use in ethylene oxide sterilizers

This part of EN 866 specifies requirements for self-contained biological indicator systems intended for use in the routine monitoring of the performance of sterilizers employing ethylene oxide gas as the sterilant. These are intended for use in sterilizers employing pure ethylene oxide or admixtures of the gas with diluent gases, over a sterilizing temperature range of 20 °C to 65 °C.

Biologische Systeme für die Prüfung von Sterilisatoren und Sterilisationsverfahren - Teil 8: Spezielle Anforderungen an Bio-Indikator-Einheiten für den Gebrauch in Ethylenoxid-Sterilisatoren

Dieser Teil von EN 866 legt die Anforderungen für Bio-Indikator-Einheiten fest, die bei der Routineüberwachung der Leistungsfähigkeit von Sterilisatoren verwendet werden, die mit Ethylenoxid-Gas als Sterilisiermittel arbeiten. Sie sind für die Verwendung in Sterilisatoren vorgesehen, die mit reinem Ethylenoxid-Gas oder Gemischen aus diesem Gas und anderen Gasen bei Sterilisationstemperaturen zwischen 20 °C und 65 °C betrieben werden.

Systemes biologiques pour l'essai des stérilisateurs et les procédés de stérilisation - Partie 8: Exigences particulieres pour les systemes autonomes d'indicateurs biologiques destinés a etre utilisés dans des stérilisateurs a l'oxyde d'éthylene

La présente partie de l'EN 866 spécifie les exigences pour les systemes autonomes d'indicateurs biologiques dont l'utilisation est prévue pour l'évaluation de la performance de stérilisateurs employant de l'oxyde d'éthylene gazeux comme agent stérilisant. Ils sont destinés a etre utilisés dans des stérilisateurs utilisant de l'oxyde d'éthylene pur ou des mélanges de ce gaz avec des gaz diluants et fonctionnant sur une plage de températures comprise entre 20 °C et 65 °C.

Biološki sistemi za preskušanje sterilizatorjev in sterilizacijskih postopkov - 8. del: Posebne zahteve za sisteme s pripravljenimi biološkimi indikatorji pri uporabi sterilizacije z etilenoksidom

General Information

Status
Withdrawn
Publication Date
30-Jun-2000
Withdrawal Date
30-Sep-2006
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
01-Oct-2006
Due Date
01-Oct-2006
Completion Date
01-Oct-2006

Relations

Buy Standard

Standard
EN 866-8:2000
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 866-8:2000
01-julij-2000
Biološki sistemi za preskušanje sterilizatorjev in sterilizacijskih postopkov - 8. del:
Posebne zahteve za sisteme s pripravljenimi biološkimi indikatorji pri uporabi
sterilizacije z etilenoksidom
Biological systems for testing sterilizers and sterilization processes - Part 8: Particular
requirements for self-contained biological indicator systems for use in ethylene oxide
sterilizers
Biologische Systeme für die Prüfung von Sterilisatoren und Sterilisationsverfahren - Teil
8: Spezielle Anforderungen an Bio-Indikator-Einheiten für den Gebrauch in Ethylenoxid-
Sterilisatoren
Systemes biologiques pour l'essai des stérilisateurs et les procédés de stérilisation -
Partie 8: Exigences particulieres pour les systemes autonomes d'indicateurs biologiques
destinés a etre utilisés dans des stérilisateurs a l'oxyde d'éthylene
Ta slovenski standard je istoveten z: EN 866-8:1999
ICS:
11.080.10 Sterilizacijska oprema Sterilizing equipment
SIST EN 866-8:2000 en
2003-01.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.