Eurocode 6 - Design of masonry structures - Part 2: Design considerations, selection of materials and execution of masonry

(1)P The scope of Eurocode 6 for Masonry Structures as given in 1.1.1 of EN 1996-1-1 applies also to this Part 2.
(2)P Part 2 of Eurocode 6 gives basic rules for the selection of materials and execution of masonry to enable it to comply with the design assumptions of the other parts of Eurocode 6. With the exception of the items given in 1.1(3)P, the scope of Part 2 deals with ordinary aspects of masonry design and execution including:
   the selection of masonry materials;
   factors affecting the performance and durability of masonry;
   resistance of buildings to moisture penetration;
   storage, preparation and use of materials on site;
   the execution of masonry;
   masonry protection during execution;
NOTE 1. Where general guidance only is given, additional guidance based on local conditions and practice may be made available in non contradictory complementary documents which may be referred to in the National Annex.
NOTE 2. The scope of Eurocode 6 excludes seismic, thermal and acoustic functional performance of masonry structures;
(3)P Part 2 of Eurocode 6 does not cover the following items:
   those aspects of masonry covered in other parts of Eurocode 6;
   aesthetic aspects;
   applied finishes;
   health & safety of persons engaged in the design or execution of masonry;
   the environmental effects of masonry buildings, civil engineering works and structures on their surroundings.

Eurocode 6 - Bemessung und Konstruktion von Mauerwerksbauten - Teil 2: Planung, Auswahl der Baustoffe und Ausführung von Mauerwerk

(1)P   Der in EN 1996 1 1, 1.1.1, beschriebene Anwendungsbereich des Eurocodes 6 für Mauerwerksbauten gilt auch für den vorliegenden Teil 2.
(2)P   Teil 2 des Eurocodes 6 enthält Grundregeln für die Auswahl von Baustoffen und Ausführung von Mauerwerk mit dem Ziel, den der Bemessung und Konstruktion zugrunde zu legenden Annahmen der anderen Teile des Eurocodes 6 zu entsprechen. Mit Ausnahme der in 1.1(3)P angegebenen Aufzählungen gilt der Anwendungsbereich von Teil 2 für die üblichen Aspekte der Planung sowie der Ausführung von Mauerwerk; dazu gehören:
   die Auswahl der Baustoffe;
   Faktoren, die die Eigenschaften und Dauerhaftigkeit des Mauerwerks beeinflussen;
   der Widerstand der Bauwerke gegen das Eindringen von Feuchte;
   die Lagerung, Vorbereitung und Verwendung von Baustoffen auf der Baustelle;
   die Ausführung des Mauerwerks;
   der Schutz des Mauerwerks während der Ausführung.
ANMERKUNG 1   Wenn nur allgemeine Leitlinien angegeben sind, darf im Nationalen Anhang auf zusätzliche Leitlinien, die auf der Grundlage der örtlichen Bedingungen und Verfahrensweisen erstellt wurden und in nicht entgegenstehenden, ergänzenden Dokumenten enthalten sind, verwiesen werden.
ANMERKUNG 2   Der Anwendungsbereich des Eurocodes 6 schließt das Leistungsvermögen des Mauerwerks in Bezug auf Erdbebensicherheit, Wärme- und Schalldämmung aus.
(3)P   Teil 2 des Eurocodes 6 gilt nicht für:
   die in anderen Teilen des Eurocodes 6 behandelten Mauerwerksaspekte;
   ästhetische Aspekte;
   Oberflächenbehandlungen;
   die Gesundheit und Sicherheit der mit der Planung oder der Ausführung von Mauerwerk beschäftigten Personen;
   die Umwelteinflüsse von Mauerwerksbauten, Ingenieurbauten und Tragwerken auf ihre Umgebung.

Eurocode 6 - Calcul des ouvrages en maçonnerie - Partie 2: Conception, choix des matériaux et mise en oeuvre des maçonneries

(1)P  Le domaine d'application de l'Eurocode 6 pour les ouvrages en maçonnerie tel qu'il est donné au paragraphe 1.1.1 de l'EN 1996 1 1 s'applique également a cette partie.
(2)P  La partie 2 de l'Eurocode 6 énonce les regles fondamentales pour le choix des matériaux et la mise en ?uvre des maçonneries, afin que ces dernieres soient conformes aux hypotheses de conception des autres parties de l'Eurocode 6. Excepté pour les points indiqués au paragraphe 1.1(3)P, cette partie traite des aspects ordinaires de la conception et de la construction de maçonneries, y compris :
   le choix des matériaux de maçonnerie ;
   les facteurs influençant les performances et la durabilité de la maçonnerie ;
   la résistance des ouvrages a la pénétration de l'humidité ;
   le stockage, la préparation et l'utilisation des matériaux sur site ;
   la mise en ?uvre des maçonneries ;
   la protection des maçonneries au cours de la construction.
NOTE 1   Lorsque seules des indications générales sont fournies, des informations sur les conditions et pratiques locales peuvent etre rendues disponibles dans des documents complémentaires non contradictoires a référencer dans une Annexe Nationale.
NOTE 2   Le domaine d'application de l'Eurocode 6 exclut les performances fonctionnelles sismiques, thermiques et acoustiques des ouvrages en maçonnerie.
(3)P  La partie 2 de l'Eurocode 6 ne couvre pas les points suivants :
   les aspects de la maçonnerie couverts dans d'autres parties de l'Eurocode 6 ;
   les aspects esthétiques ;
   les finitions appliquées ;
   l'hygiene et la sécurité des personnes engagées dans la conception ou la mise en ?uvre des maçonneries ;
   les effets sur l'environnement des ouvrages de maçonnerie, des constructions et des ouvrages de génie civil sur leur milieu.

Evrokod 6: Projektiranje zidanih konstrukcij - 2. del: Projektiranje z upoštevanjem izbire materialov in izvedbo zidovja

General Information

Status
Published
Publication Date
30-Apr-2006
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-May-2006
Due Date
01-May-2006
Completion Date
01-May-2006

Relations

Buy Standard

Standard
EN 1996-2:2006
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Eurocode 6 - Design of masonry structures - Part 2: Design considerations, selection of materials and execution of masonryEvrokod 6: Projektiranje zidanih konstrukcij - 2. del: Projektiranje z upoštevanjem izbire materialov in izvedbo zidovjaEurocode 6 - Calcul des ouvrages en maçonnerie - Partie 2: Conception, choix des matériaux et mise en oeuvre des maçonneriesEurocode 6 - Bemessung und Konstruktion von Mauerwerksbauten - Teil 2: Planung, Auswahl der Baustoffe und Ausführung von MauerwerkTa slovenski standard je istoveten z:EN 1996-2:2006SIST EN 1996-2:2006en91.080.30Zidane konstrukcijeMasonry91.010.30Technical aspectsICS:SIST ENV 1996-2:20041DGRPHãþDSLOVENSKI
STANDARDSIST EN 1996-2:200601-maj-2006







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1996-2January 2006ICS 91.010.30; 91.080.30Supersedes ENV 1996-2:1998
English VersionEurocode 6 - Design of masonry structures - Part 2: Designconsiderations, selection of materials and execution of masonryEurocode 6 - Calcul des ouvrages en maçonnerie - Partie2: Conception, choix des matériaux et mise en oeuvre desmaçonneriesEurocode 6 - Bemessung und Konstruktion vonMauerwerksbauten - Teil 2: Planung, Auswahl derBaustoffe und Ausführung von MauerwerkThis European Standard was approved by CEN on 24 November 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1996-2:2006: E



EN 1996-2:2006 (E) 2 Contents Page Background of the Eurocode programme.4 Status and field of application of Eurocodes.5 National Standards implementing Eurocodes.6 Links between Eurocodes and harmonised technical specifications (ENs and ETAs) for products.7 Additional information specific to EN 1996-2.7 National annex for EN 1996-2.7 1 General.8 1.1 Scope of Part 2 of Eurocode 6.8 1.2 Normative references.9 1.3 Assumptions.9 1.4 Distinction between principles and application rules.9 1.5 Definitions.10 1.5.1 General.10 1.5.2 Terms and definitions relating to communication of design.10 1.5.3 Terms relating to climatic factors and exposure conditions.10 1.5.4 Term relating to masonry units.10 1.5.5 Other terms.11 1.6 Symbols.11 2 Design Considerations.11 2.1 Factors affecting the durability of masonry.11 2.1.1 General.11 2.1.2 Classification of environmental conditions.11 2.1.2.1 Micro conditions of exposure.11 2.1.2.2 Climatic factors (macro conditions of exposure).12 2.1.3 Aggressive chemical environments.12 2.2 Selection of materials.13 2.2.1 General.13 2.2.2 Masonry units.13 2.2.3 Masonry mortar and concrete infill.14 2.2.3.1 General.14 2.2.3.2 Selection of factory made masonry mortar and concrete infill.14 2.2.3.3 Selection of site-made masonry mortar and concrete infill.14 2.2.4 Ancillary components and reinforcement.15 2.3 Masonry.15 2.3.1 Detailing.15 2.3.2 Joint finishes.15 2.3.3 Masonry movement.15 2.3.4 Movement joints.16



EN 1996-2:2006 (E)
3 2.3.4.1 General.16 2.3.4.2 Spacing of movement joints.17 2.3.5 Permissible deviations.17 2.3.6 Resistance to moisture penetration through external walls.18 3 Execution.18 3.1 General.18 3.2 Acceptance, handling and storage of materials.18 3.2.1 General.18 3.2.2 Reinforcement and prestressing materials.18 3.3 Preparation of materials.19 3.3.1 Site-made mortars and concrete infill.19 3.3.1.1 General.19 3.3.1.2 Chloride content.19 3.3.1.3 Strength of mortar and concrete infill.19 3.3.1.4 Admixtures and additions.19 3.3.1.5 Gauging.19 3.3.1.6 Mixing method and mixing time.20 3.3.1.7 Workable life of mortars and concrete infill containing cement.20 3.3.1.8 Mixing in cold weather.20 3.3.2 Factory made mortars, pre-batched mortars, pre-mixed lime sand mortars and ready mixed concrete infill.20 3.4 Permissible deviations.21 3.5 Execution of masonry.23 3.5.1 General.23 3.5.2 Laying masonry units.23 3.5.3 Pointing and jointing for masonry other than thin layer masonry.24 3.5.3.1 Pointing.24 3.5.3.2 Jointing.24 3.5.4 Incorporation of damp proof course membranes.24 3.5.5 Movement joints.24 3.5.6 Incorporation of thermal insulation materials.24 3.5.7 Cleaning facing masonry.24 3.6 Curing and protective procedures during execution.24 3.6.1 General.24 3.6.2 Protection against rain.25 3.6.3 Protection against freeze/thaw cycling.25 3.6.4 Protection against effects of low humidity.25 3.6.5 Protection against mechanical damage.25 3.6.6 Construction height of masonry.25 A.1 Classification.26 A.2 Exposure to wetting.27 B.1 Selection of masonry units and mortar.29 C.1 Exposure classes.31 C.2 Selection of materials.31



EN 1996-2:2006 (E) 4 Foreword This document EN 1996-2 has been prepared by Technical Committee CEN/TC250 “Structural Eurocodes”, the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2006, and conflicting national standards shall be withdrawn at the latest by March 2010. CEN/TC 250 is responsible for all Structural Eurocodes. This document supersedes ENV 1996-2:1998 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Background of the Eurocode programme In 1975, the Commission of the European Community decided on an action programme in the field of construction, based on Article 95 of the Treaty. The objective of the programme was the elimination of technical obstacles to trade and the harmonisation of technical specifications. Within this action programme, the Commission took the initiative to establish a set of harmonised technical rules for the design of construction works which, in a first stage, would serve as an alternative to the national rules in force in the Member States and, ultimately, would replace them.
For fifteen years, the Commission, with the help of a Steering Committee with Representatives of Member States, conducted the development of the Eurocodes programme, which led to the first generation of European codes in the 1980s.
In 1989, the Commission and the Member States of the EU and EFTA decided, on the basis of an agreement1) between the Commission and CEN, to transfer the preparation and the publication of the Eurocodes to the CEN through a series of Mandates, in order to provide them with a future status of European Standard (EN). This links de facto the Eurocodes with the provisions of all the Council’s Directives and/or Commission’s Decisions dealing with European standards (eg. the Council Directive 89/106/EEC on construction products - CPD - and Council Directives 93/37/EEC,
1) Agreement between the Commission of the European Communities and the European Committee for Standardisation (CEN) concerning the work on EUROCODES for the design of building and civil engineering works (BC/CEN/03/89).



EN 1996-2:2006 (E)
5 92/50/EEC and 89/440/EEC on public works and services and equivalent EFTA Directives initiated in pursuit of setting up the internal market). The Structural Eurocode programme comprises the following standards generally consisting of a number of parts: EN 1990, Eurocode: Basis of structural design EN 1991, Eurocode 1: Actions on structures. EN 1992, Eurocode 2: Design of concrete structures. EN 1993, Eurocode 3: Design of steel structures. EN 1994, Eurocode 4: Design of composite steel and concrete structures. EN 1995, Eurocode 5: Design of timber structures. EN 1996, Eurocode 6: Design of masonry structures. EN 1997, Eurocode 7: Geotechnical design. EN 1998, Eurocode 8: Design of structures for earthquake resistance. EN 1999, Eurocode 9: Design of aluminium structures. Eurocode standards recognise the responsibility of regulatory authorities in each Member State and have safeguarded their right to determine values related to regulatory safety matters at national level where these continue to vary from State to State. Status and field of application of Eurocodes The Member States of the EU and EFTA recognise that Eurocodes serve as reference documents for the following purposes:  as a means to prove compliance of building and civil engineering works with the essential requirements of Council Directive 89/106/EEC, particularly Essential Requirement N°1  Mechanical resistance and stability  and Essential Requirement N°2  Safety in case of fire;  as a basis for specifying contracts for construction works and related engineering services;  as a framework for drawing up harmonised technical specifications for construction products (ENs and ETAs). The Eurocodes, as far as they concern the construction works themselves, have a direct relationship with the Interpretative Documents2) referred to in Article 12 of the CPD, although they are of a
2) According to Article 3.3 of the CPD, the essential requirements (ERs) shall be given concrete form in interpretative documents for the creation of the necessary links between the essential requirements and the mandates for harmonised ENs and ETAGs/ETAs.



EN 1996-2:2006 (E) 6 different nature from harmonised product standards3). Therefore, technical aspects arising from the Eurocodes work need to be adequately considered by CEN Technical Committees and/or EOTA Working Groups working on product standards with a view to achieving full compatibility of these technical specifications with the Eurocodes. The Eurocode standards provide common structural design rules for everyday use for the design of whole structures and component products of both a traditional and an innovative nature. Unusual forms of construction or design conditions are not specifically covered and additional expert consideration will be required by the designer in such cases. National Standards implementing Eurocodes The National Standards implementing Eurocodes will comprise the full text of the Eurocode (including any annexes), as published by CEN, which may be preceded by a National title page and National foreword, and may be followed by a National Annex (informative). The National Annex may only contain information on those parameters which are left open in the Eurocode for national choice, known as Nationally Determined Parameters, to be used for the design of buildings and civil engineering works to be constructed in the country concerned, ie.:  values and/or classes where alternatives are given in the Eurocode,  values to be used where a symbol only is given in the Eurocode,  country specific data (geographical, climatic etc), eg. snow map,  the procedure to be used where alternative procedures are given in the Eurocode and it may also contain:  decisions on the application of informative annexes,  references to non-contradictory complementary information to assist the user to apply the Eurocode.
3) According to Article 12 of the CPD the interpretative documents shall: a) give concrete form to the essential requirements by harmonising the terminology and the technical bases and indicating classes or levels for each requirement where necessary; b) indicate methods of correlating these classes or levels of requirement with the technical specifications, e. g. methods of calculation and of proof, technical rules for project design, etc.; c) serve as a reference for the establishment of harmonised standards and guidelines for European technical approvals. The Eurocodes, de facto, play a similar role in the field of ER 1 and a part of ER 2.



EN 1996-2:2006 (E)
7 Links between Eurocodes and harmonised technical specifications (ENs and ETAs) for products There is a need for consistency between the harmonised technical specifications for construction products and the technical rules for works4) Furthermore, all the information accompanying the CE Marking of the construction products which refer to Eurocodes shall clearly mention which Nationally Determined Parameters have been taken into account. This European Standard is part of EN 1996 which comprises the following Parts: Part 1-1: General - Rules for reinforced and unreinforced masonry Part 1-2: General rules - Structural fire design. Part 2: Design considerations, selection of materials and execution of masonry. Part 3: Simplified calculation methods for unreinforced masonry structures EN 1996-2 describes the principles and requirements for design considerations, selection of materials and execution of masonry structures. For the design of new structures, EN 1996-1-1 is intended to be used, for direct application, together with ENs 1990, 1991, 1992, 1993, 1994, 1995, 1997, 1998 and 1999. EN 1996-2 is intended to be used together with EN 1990, EN 1991-1-2, EN 1996-1-1, EN 1996-1-2 and EN 1996-3. Additional information specific to EN 1996-2 The scope of Eurocode 6 is defined in EN 1996-1-1, and this includes information on the other parts of Eurocode 6. National Annex for EN 1996-2 This standard gives alternative procedures, values and recommendations for classes with notes indicating where national choices may have to be made. Therefore the National Standard implementing EN 1996-2 should have a National Annex containing all Nationally Determined Parameters to be used for the design of buildings and civil engineering works to be constructed in the relevant country.
National choice is allowed in EN 1996-2 through clauses:
 2.3.4.2(2)  3.5.3.1(1)
4) see Article 3.3 and Article 12 of the CPD, as well as clauses 4.2, 4.3.1, 4.3.2 and 5.2 of ID 1.



EN 1996-2:2006 (E) 8 In addition to general references to non-contradictory complementary information specific references may be made through clauses:  1.1.(2)P  2.3.1.(1)  3.4.(3) 1 General 1.1 Scope of Part 2 of Eurocode 6 (1)P The scope of Eurocode 6 for Masonry Structures as given in 1.1.1 of EN 1996-1-1:2005 applies also to this EN 1996-2. (2)P EN 1996-2 gives basic rules for the selection of materials and execution of masonry to enable it to comply with the design assumptions of the other parts of Eurocode 6. With the exception of the items given in 1.1(3)P, the scope of Part 2 deals with ordinary aspects of masonry design and execution including:  the selection of masonry materials;  factors affecting the performance and durability of masonry;  resistance of buildings to moisture penetration;  storage, preparation and use of materials on site;  the execution of masonry;  masonry protection during execution; NOTE 1. Where general guidance only is given, additional guidance based on local conditions and practice may be made available in non contradictory complementary documents which may be referred to in the National Annex. NOTE 2. The scope of Eurocode 6 excludes seismic, thermal and acoustic functional performance of masonry structures; (3)P
EN 1996-2 does not cover the following items:
 those aspects of masonry covered in other parts of Eurocode 6;  aesthetic aspects;  applied finishes;  health
and safety of persons engaged in the design or execution of masonry;  the environmental effects of masonry buildings, civil engineering works and structures on their surroundings.



EN 1996-2:2006 (E)
9 1.2 Normative references (1)P This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication applies (including amendments).  EN 206-1, Concrete -Part 1: Specification, performance, production and conformity
 EN 771 (all parts), Specification for masonry units  EN 998-2, Specification for mortar for masonry – Part 2: Masonry mortar  EN 845 (all parts), Specification for ancillary components for masonry  EN 1015-11, Methods of test for mortar for masonry - Part 11: Determination of flexural and compressive strength of hardened mortar  EN 1015-17, Methods of test for mortar for masonry – Part 17: Determination of water-soluble chloride content of fresh mortars  EN 1052 (all parts), Methods of test for masonry  EN 1990, Eurocode: Basis of structural design
 EN 1996-1-1, Eurocode 6: Design of masonry structures - Part 1: General rules for reinforced and unreinforced masonry structures  EN 13914-1, The design, preparation and application of external rendering and internal plastering - Part 1: External rendering 1.3 Assumptions (1)P In addition to the assumptions given in 1.3 of EN 1990:2002 the following assumptions apply in this EN 1996-2:  Design shall be in accordance with Section 2 taking into account Section 3.  Execution shall be in accordance with Section 3 taking into account Section 2. (2) The design Principles are valid only when the Principles for execution in Section 3 are complied with. 1.4 Distinction between Principles and Application Rules (1)P The rules in 1.4 of EN 1990:2002 apply to this EN 1996-2.



EN 1996-2:2006 (E) 10 1.5 Definitions 1.5.1 General (1) The terms and definitions given in 1.5 of EN 1990:2002 apply to this EN 1996-2. (2) The terms and definitions used in
EN 1996-1-1 apply to this EN 1996-2. (3) Additional terms and definitions used in this EN 1996-2 are given the meanings contained in 1.5.2 to 1.5.5, inclusive. 1.5.2 Terms and definitions relating to communication of design 1.5.2.1 design specification documents describing the designer's requirements for the construction, including drawings, schedules, test reports, references to parts of other documents and written instructions 1.5.3 Terms relating to climatic factors and exposure conditions 1.5.3.1
macro conditions climatic factors depending on the general climate of the region in which a structure is built, modified by the effects of local topography and/or other aspects of the site
1.5.3.2 micro conditions localised climatic and environmental factors depending on the position of a masonry element within the overall structure and taking into account the effect of protection, or lack of protection, by constructional details or finishes 1.5.4 Term relating to masonry units 1.5.4.1 accessory masonry unit a masonry unit which is shaped to provide a particular function, e.g. to complete the geometry of the masonry



EN 1996-2:2006 (E)
11 1.5.5 Other terms 1.5.5.1 applied finish a covering of material bonded to the surface of the masonry 1.5.5.2 cavity width the distance perpendicular to the plane of the wall between the cavity faces of the masonry leaves of a cavity wall or that between the cavity face of a veneer wall and the masonry backing structure 1.5.5.3 cladding a covering of material(s) fastened or anchored in front of the masonry and not in general bonded to it 1.6 Symbols (1)P For the purpose of this standard the symbols in accordance with 1.6 of EN 1996-1-1:2005 apply. (2)P Other symbols used in this EN 1996-2 are: dp minimum depth for pointing lm maximum horizontal distance between vertical movement joints in external non-loadbearing walls; 2 Design considerations 2.1 Factors affecting the durability of masonry 2.1.1 General (1)P Masonry shall be designed to have the performance required for its intended use. 2.1.2 Classification of environmental conditions
2.1.2.1 Micro conditions of exposure (1)P The micro conditions to which the masonry is expected to be exposed shall be taken into account in the design. (2) When deciding the micro conditions of exposure of the masonry, the effect of applied finishes, protective claddings and details should be taken into account.



EN 1996-2:2006 (E) 12 (3) Micro conditions of exposure of completed masonry should be categorised into classes, as follows:
MX1 - In a dry environment;
MX2 - Exposed to moisture or wetting;
MX3 - Exposed to moisture or wetting plus freeze/thaw cycling;
MX4 - Exposed to saturated salt air or seawater;
MX5 - In an aggressive chemical environment. NOTE When necessary, more closely defined conditions within these classes may be specified using the sub-classes in Annex A (e.g. MX2.1 or MX2.2 and M X 3.1 or M X 3.2). (4) To produce masonry that meets specified performance criteria and withstands the environmental conditions to which it is exposed, the determination of the exposure class should take into account:  climatic factors;  severity of exposure to moisture or wetting;  exposure to freeze/thaw cycling;  presence of chemical materials that may lead to damaging reactions. 2.1.2.2 Climatic factors (macro conditions of exposure) (1)P The effect of the macro conditions on the micro conditions shall be
...