Blank Detail Specification: Fixed low power film resistors

A Blank Detail Specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements shall not be considered as being in accordance with European standards nor shall they be so described.

Vordruck für die Bauartspezifikation: Schicht-Festwiderstände niedriger Belastbarkeit

Spécification particulière: Résistances fixes à couche et à faible dissipation

Okvirna podrobna specifikacija: Fiksni upori majhnih moči

General Information

Status
Published
Publication Date
20-Apr-2008
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Mar-2008
Due Date
01-Jun-2008
Completion Date
21-Apr-2008

Relations

Buy Standard

Standard
EN 140101:2008
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Blank Detail Specification: Fixed low power film resistorsSpécification particulière: Résistances fixes à couche et à faible dissipationVordruck für die Bauartspezifikation: Schicht-Festwiderstände niedriger Belastbarkeit31.040.10Fiksni uporFixed resistorsICS:SIST EN 140101:2008en,fr,deTa slovenski standard je istoveten z:EN 140101:200801-junij-2008SIST EN 140101:2008SLOVENSKI
STANDARDSIST EN 140101:20021DGRPHãþD







EUROPEAN STANDARD EN 140101 NORME EUROPÉENNE
EUROPÄISCHE NORM March 2008
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 140101:2008 E
ICS 31.040.10 Supersedes EN 140101:1996
English version
Blank Detail Specification:
Fixed low power film resistors
Spécification particulière:
Résistances fixes à couche
et à faible dissipation
Vordruck für die Bauartspezifikation: Schicht-Festwiderstände niedriger Belastbarkeit
This European Standard was approved by CENELEC on 2007-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.



EN 140101:2008 – 2 – Foreword This European Standard was prepared by the Technical Committee CENELEC TC 40XB, Resistors.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 140101 on 2007-11-01. This European Standard supersedes EN 140101:1996. The following dates were fixed: – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2008-11-01 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2010-11-01 Preceding documents on the subject covered by this specification have been: − CECC 40 101:1981. Compared to the superseded standard, the following changes have been implemented: − modification of the title; − introduction of a test on the resistance to electrostatic discharge (ESD) in 1.6 and in Annex A; − introduction of description and test methods for lead-free soldering in 1.9.3 and in Annex A; − introduction of code letters for the temperature coefficient (TCR) as in EN 60062; − revision of ordering information in 1.8.4; − adoption of the IECQ rules of procedure, IEC QC 001002-3; − revision of the sample quantities and the sequence of tests in Annex A; − editorial revision.
This specification supports the building of a series of documents describing fixed low power film resistors as follows: − EN 60115-1 Fixed resistors for use in electronic equipment – Part 1: Generic specification
(IEC 60115-1, mod.) − EN 140100 Sectional specification: Fixed low power film resistors − EN 140101-xxx Relevant detail specification(s) written on the basis of this Blank Detail Specification. __________



– 3 – EN 140101:2008 Contents Introduction . 4 1 Characteristics and ratings . 5 1.1 Dimensions and ratings . 5 1.2 Derating curve . 6 1.3 Resistance range and tolerance on rated resistance . 7 1.4 Variation of resistance with temperature and temperature rise . 8 1.5 Climatic categories . 8 1.6 Limits for change of resistance at tests . 9 1.7 Non-linear properties . 9 1.8 Tests related to soldering . 10 1.9 Marking, packaging and ordering designation . 11 1.10 Additional information (not for inspection purpose) . 12 2 Quality assessment procedures . 13 2.1 General . 13 2.2 Qualification Approval . 14 2.3 Quality Conformance Inspection . 14 Annex A (normative)
Fixed sample size Qualification Approval and Quality Conformance Inspection test schedule for fixed low power film resistors . 16 Annex B (informative)
Letter symbols and abbreviations . 24 Bibliography . 26 Figure 1 – Outline and dimensions (see Table 1) . 5 Figure 2 – Derating curve . 6 Figure 3 – Limits of non-linearity in resistance . 10 Table 1 – Style and dimensions . 5 Table 2a – Ratings . 6 Table 2b – Ratings for 0 Ω resistors . 6 Table 3a – Resistance range and tolerance on rated resistance for Version A . 7 Table 3b – Resistance range and tolerance on rated resistance for Version E . 7 Table 4 – Temperature coefficients and percentage change of resistance . 8 Table 5 – Limit of temperature rise . 8 Table 6 – Climatic categories . 8 Table 7a – Limits for change of resistance at tests . 9 Table 7b – Limits for change of resistance at tests . 9 Table A.1 – Test schedule for Qualification Approval and Quality Conformance Inspection,
lot-by-lot tests, assessment level EZ . 16 Table A.2 – Test schedule for Qualification Approval and Quality Conformance Inspection,
periodic tests, assessment level EZ . 19



EN 140101:2008 – 4 – Introduction Blank Detail Specification A Blank Detail Specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements shall not be considered as being in accordance with European standards nor shall they be so described. In the preparation of the detail specification the content of EN 140100:2008, 1.2 shall be taken into account. The detail specification should be written by using the preferred values given in EN 140100. The detail specification should contain a table of contents prior the first page of the actual specification. For the use of SI units refer to ISO 1000, for the use of letter symbols to be used in electrical technology refer to EN 60027-1. Notes in this document shall be considered as guidance and are not part of the detail specification itself. Identification of the detail specification and the component The first page of the detail specification should have the layout recommended on page 5. The numbers in square brackets correspond to the indications to be completed thereunder: [1] the name of the National Standards Organisation under whose authority the detail specification is published, and if applicable, the organisation from whom the detail specification is available; [2] the CECC symbol and the number allocated to the detail specification by the CENELEC General Secretariat; [3] the number and issue number of the EN generic and sectional specification as relevant; also national reference if different; [4] the national number of the detail specification, date of issue and any further information required by the national system, together with any amendment numbers, if different from the EN number; [5] a brief description of the component or range of components; [6] information on typical construction (where applicable); [7] an outline drawing with the main dimensions which are of importance for interchangeability and/or reference to the appropriate national or international document for outlines. Alternatively, this drawing may be given in an annex to the detail specification; [8] the level of quality assessment covered by the detail specification. For [5] and [6] the text to be given in the detail specification should be suitable for an entry in a register of approvals and the “CENELEC Catalogue of European Standards”.



– 5 – EN 140101:2008 Specification available from:
[1] CENELEC Central Secretariat, Rue de Stassart 35 B-1050 Brussels, or from the addresses shown on the inside cover EN 140101
[2]Electronic components of assessed quality in accordance with: [3] EN 60115-1:2001 + A1:2001 EN 140100:2008 Issue 2 [4] March 2008
[7] Other shapes are permitted within the given dimensions. Figure 1 – Outline and dimensions (see Table 1) Fixed low power film resistors [5] (Description of the component) [6] Assessment level EZ a [8] Version A: with 100 %-test Version E: with failure rate level and 100 %-test Stability classes … a For explanation on assessment level EZ see 2.1.1. NOTE Version E is optional. 1 Characteristics and ratings Various parameters of this component are precisely defined in this specification. Unspecified parameters may vary from one component to another. 1.1 Dimensions and ratings Table 1 – Style and dimensions Style Length L mm Diameter D mm d a mm e b mm c c mm Mass dmg Code x min. max. min. max.
max. max.
a Permissible tolerance according to HD 349. b Standard distance for the axis to bent leads. Smaller modules may be agreed between manufacturer and customer. c Length of excess protective coating. d For information only. x Optional column for additional information (e.g. size code). NOTE See EN 140100:2008, 1.2 b). Information about manufacturers who have components qualified to this detail specification is available in the approvals section of the website http://www.iecq.org.



EN 140101:2008 – 6 – Table 2a – Ratings Style x Rated dissipation P70 mW Limiting element voltaged.c. or a.c. (r.m.s.) UmaxV Insulation voltage d.c. or a.c. (peak) Uins V 1 min continuous
x Optional column for additional information (e.g. stability class, rated dissipation at other ambient temperature than 70 °C) NOTE 1
See EN 140100:2008, 1.2 h), i), j). NOTE 2
Should it be necessary to control further parameters, a more detailed specification should be used. Then the additional test method(s) shall be fully described and appropriate limits and inspection levels (IL) shall be specified. Table 2b – Ratings for 0 Ω resistors Style Maximum current Imax A Maximum resistance Rr max mΩ Insulation voltage d.c. or a.c. (peak) Uins V 1 min continuous
NOTE
Table 2b is optional.
1.2 Derating curve Resistors covered by this specification are derated according to the following diagram: Ambient temperature ϑaPercentage of rated dissipation0 %60 %40 %20 %100 %80 %70 °CLower category temperature (LCT)Upper category temperature (UCT) Figure 2 – Derating curve
NOTE 1 See EN 140100:2008, 1.2 h). NOTE 2 A larger area of operation may be given in the detail specification, provided it includes all the area given above.



– 7 – EN 140101:2008 1.3 Resistance range and tolerance on rated resistance 1.3.1 Version A The following combinations of temperature coefficient and tolerance on rated resistance may be approved only. Products from this extent shall be used for the Qualification approval according to 2.2.1 and for the Quality conformance inspection according to 2.3. Resistance values of an E-series according to IEC 60063 shall be used.
The qualification of resistance values below or beyond the specified resistance values is permitted, if they fulfil the requirements of the closest stability class (e.g. Style … shall fulfil the requirements of stability class …). Table 3a – Resistance range and tolerance on rated resistance for Version A Style Tolerance on rated resistance Temperature coefficient Resistance
range Stability class b % Code a 10-6/K
0 Ω resistors according to Table 2b for styles … a Code letters according to EN 60062. b For the category temperatures of stability classes refer to Table 6. 1.3.2 Version E The following combinations of temperature coefficient, tolerance on rated resistance, resistance range and E-series according to IEC 60063 are permitted only. Products from this extent shall be used for the Qualification approval according to 2.2.2 and for the Quality conformance inspection according to 2.3 and are permitted only: Table 3b – Resistance range and tolerance on rated resistance for Version E Style Tolerance on rated resistance Temperature coefficient Resistance
range Stability class b E series % Code a 10-6/K
0 Ω resistors according to Table 2b for styles … a Code letters according to EN 60062. b For the category temperatures of stability classes refer to Table 6. NOTE
Table 3b is only required for Version E and should be a subset of Table 3a.



EN 140101:2008 – 8 – 1.4 Variation of resistance with temperature and temperature rise Table 4 – Temperature coefficients and percentage change of resistance Temperature coefficient Limit of resistance change ∆R/R %
10-6/K Code a Code b LCT / Reference temp. °C Reference temperature / UCT °C
-… / 20 -… / 20 20 / … 20 / … 20 / …
a Code letters according to EN 60062. b Historical code letters according to …, for information only. NOTE 1 Second code column with historical reference is optional. NOTE 2 See EN 140100:2008, 1.2 g). Table 5 – Limit of temperature rise Stability class Limit of temperature rise
at rated dissipation
Tr ≤ …
Tr ≤ …
1.5 Climatic categories NOTE
See EN 140100:2008, 1.2 c). Table 6 – Climatic categories Stability class Climatic category LCT / UCT / Duration
… / … / …
… / … /



– 9 – EN 140101:2008 1.6 Limits for change of resistance at tests NOTE
See EN 140100:2008, 1.2 d). Table 7a – Limits for change of resistance at tests
Stability class Limit of resistance change ∆R/R EN 60115-1 a, 4.23 Climatic
sequence 4.24 Damp heat,
steady state 4.25.3 Endurance at
upper category
temperature EN 60115-1 a, 4.25.1 Endurance at 70 °C
EN 60115-1 a, 4.13 Overload 4.16 Robustness of
terminations 4.18 Resistance to
soldering heat 4.19 Rapid change
of temperature, 5 cycles 4.22 Vibration 1 000 h Extended, 8 000 h
a EN 60115-1:2001 + A1:2001.
Table 7b – Limits for change of resistance at tests
Stability class Limit of resistance change ∆R/R
EN 60115-1 a, 4.19 Rapid change
of temperature, ≥ 100 cycles EN 60115-1 a, 4.27 Single pulse
high voltage
overload test EN 60115-1 a, 4.27 Periodic
electric
overload EN 60115-1 a, 4.40 Electrostatic discharge b
a EN 60115-1:2001 + A1:2001. b Human body model (HBM) according to EN 61340-3-1, 3 positive + 3 negative discharges.
1.7 Non-linear properties If for resistors in the range 10 Ω ≤ R ≤ … measurement of non-linearity is required according to 2.1.2,
the measured values shall be above the limits given in the diagram below. The resistors shall be tested according to IEC/TR 60440 where the test voltage shall be the rated voltage.



EN 140101:2008 – 10 – Resistance value RAttenuation of 3rd Harmonic A310 Ω100 Ω1 kΩ10 kΩ100 kΩ1 MΩ10 MΩ130 dB120 dB110 dB100 dB90 dB80 dB70 dB60 dB NOTE
The X-scale shall be in accordance to the resistance range given in Table 3a. Figure 3 – Limits of non-linearity in resistance 1.8 Tests related to soldering 1.8.1 Severities for solderability testing Solderability testing shall be preceded by an accelerated ageing according to IEC 60068-2-20, Test Ta, Ageing 3a: 4 h at 155 °C dry heat. To prove the compatibility of resistors according to this specification with lead-free solder, e.g. SnCu, SnCuNi, SnAg or SnAgCu, and traditional SnPb solder, solderability shall be tested with both types of solder. a) Solderability with traditional SnPb solder shall be tested according to IEC 60068-2-20, Test Ta, solder bath method, with the following conditions:
solder alloy: Sn60Pb40 or Sn63Pb37;
solder bath temperature: (235 ± 5) °C;
immersion time: (2 ± 0,2) s. b) Solderability with lead-free solder shall be tested according to IEC 60068-2-20, Test Ta, solder bath method, with the following conditions:
solder alloy: Sn99,3Cu0,7;
solder bath temperature: (250 ± 5) °C;
immersion time: (3 ± 0,3) s,
or
solder alloy: Sn96,5Ag3,0Cu0,5;
solder bath temperature: (245 ± 5) °C;
immersion time: (3 ± 0,3) s.



– 11 – EN 140101:2008 1.8.2 Severities for testing resistance to soldering heat The severity of the resistance to soldering heat test is determined by the peak temperature and by the temperature slopes before and after the dwell time at the peak temperature. The choice of the solder alloy from the range given below is not known to have any impact on the results of this test. Resistance to soldering heat for a conventional SnPb soldering process and for a lead-free soldering process shall be covered by one test and therefore tested according to IEC 60068-2-20, Test Tb, solder bath method with the following conditions:
solder alloy: any alloy SnPb or SnCu or SnAgCu or SnAg;
solder bath temperature: (270 ± 5) °C;
immersion time: (10 ± 1) s. 1.9 Marking, packaging and ordering designation NOTE
The marking of components and packaging shall be in accordance with the requirements of EN 60115-1:2001 + A1:2001, 2.4 and EN 140100:2008, 1.2 k), l). 1.9.1 Marking of the component NOTE
Marking of the component can be mandatory or not. 1.9.2 Taping Components may be taped or untaped. Taping shall be in accordance with EN 60286-1.
1.9.3 Marking of the packaging The packaging of the component shall be marked with ordering information in accordance to 1.9.4 and additionally with − CECC or IECQ sign of conformity, − CECC or IECQ manufacturer code, − NATO manufacturer code (only Version E, if required), − date code of manufacture according to EN 60062. Additional information is permissible. 1.9.4 Ordering information Orders for resistors covered by this specification shall contain the following information: – detail specification number; – assessment level; – style; – temperature coefficient; – rated resistance; – tolerance on rated resistance; – failure rate level (only for Version E); – form of delivery, packaging method (in addition to the ordering information given in the examples below).



EN 140101:2008 – 12 – Example of the ordering information for 4,75 kΩ resistors: Version A: EN140101–xxxEZ

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.