Refrigerant compressors - Rating conditions, tolerances and presentation of manufacturer's performance data

This European Standard specifies the rating conditions, tolerances and the method of presenting manufacturer’s data for positive displacement refrigerant compressors. These include single stage compressors and single and two stage compressors using a means of fluid subcooling. This is required so that a comparison of different refrigerant compressors can be made. The data relate to the refrigerating capacity and power absorbed and include requirements for part-load operation where applicable.

Kältemittel-Verdichter - Nennbedingungen, Toleranzen und Darstellung von Leistungsdaten des Herstellers

Diese Europäische Norm legt die Nennbedingungen, Toleranzen und die Darstellung der Leistungsdaten des Herstellers für Kältemittel-Verdichter des Verdrängertyps fest. Dazu gehören einstufige Verdichter und ein- und zweistufige Verdichter mit Flüssigkeitsunterkühlung. Dies ist notwendig, damit ein Vergleich von unterschiedlichen Kältemittel-Verdichtern durchgeführt werden kann. Die Daten beziehen sich auf die Kälteleistung und die Leistungsaufnahme und schließen Korrekturfaktoren und Teillastleistungen ein, sofern zutreffend.

Compresseurs pour fluides frigorigènes - Conditions de détermination des caractéristiques, tolérances et présentation des performances par le fabricant

La présente Norme Européenne spécifie les conditions de détermination des caractéristiques, les tolérances
et le mode de présentation des performances par le fabricant, applicables aux compresseurs volumétriques
pour fluides frigorigènes. Ceux-ci incluent les compresseurs mono-étagés, ainsi que les compresseurs monoet
bi-étagés utilisant un moyen de sous-refroidissement du fluide frigorigène. La présente norme est
nécessaire afin de permettre la comparaison de différents compresseurs pour fluides frigorigènes. Les
données relatives aux performances se rapportent à la puissance frigorifique et à la puissance absorbée, et
comprennent des facteurs de correction ainsi que les performances en charge partielle, quand cela est
applicable.

Kompresorji za hladilne tekočine - Pogoji določanja nazivne moči, toleranc in predstavitev tehničnih karakteristik proizvajalca

Ta evropski standard določa pogoje določanja nazivne moči, toleranc in metod predstavitve podatkov proizvajalca za kompresorje za hladilne tekočine z izpodrivnim delovanjem. Ti vključujejo enostopenjske kompresorje ter eno- in dvostopenjske kompresorje, ki uporabljajo tekoča sredstva za globoko hlajenje. To je potrebno zaradi tega, da se lahko izvede primerjava različnih kompresorjev za hladilne tekočine. Podatki se navezujejo na zmogljivost in absorbirano moč hlajenja ter vključujejo zahteve za delovanje pri delni obremenitvi, kjer je to primerno.

General Information

Status
Published
Public Enquiry End Date
24-May-2012
Publication Date
11-Sep-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Sep-2013
Due Date
09-Nov-2013
Completion Date
12-Sep-2013

Relations

Buy Standard

Standard
EN 12900:2013
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kältemittel-Verdichter - Nennbedingungen, Toleranzen und Darstellung von Leistungsdaten des HerstellersCompresseurs pour fluides frigorigènes - Conditions de détermination des caractéristiques, tolérances et présentation des performances par le fabricantRefrigerant compressors - Rating conditions, tolerances and presentation of manufacturer's performance data27.200Hladilna tehnologijaRefrigerating technology23.140VWURMLCompressors and pneumatic machinesICS:Ta slovenski standard je istoveten z:EN 12900:2013SIST EN 12900:2013en,fr,de01-oktober-2013SIST EN 12900:2013SLOVENSKI
STANDARDSIST EN 12900:20061DGRPHãþD



SIST EN 12900:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12900
July 2013 ICS 23.140; 27.200 Supersedes EN 12900:2005English Version
Refrigerant compressors - Rating conditions, tolerances and presentation of manufacturer's performance data
Compresseurs pour fluides frigorigènes - Conditions de détermination des caractéristiques, tolérances et présentation des performances par le fabricant
Kältemittel-Verdichter - Nennbedingungen, Toleranzen und Darstellung von Leistungsdaten des Herstellers This European Standard was approved by CEN on 8 June 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12900:2013: ESIST EN 12900:2013



EN 12900:2013 (E) 2 Contents Page Foreword .3 1 Scope .4 2 Normative references .4 3 Terms and definitions .4 4 Parameters for the presentation of performance data.6 5 Requirements .8 6 Performance data.8 6.1 General .8 6.2 Tabular or graphical form .9 6.3 Polynomial form .9 7 Standard reference points . 10 8 Tolerances . 12 9 Conversion methods . 14 9.1 Suction gas superheat . 14 9.2 Compressor speed for open drive compressors . 14
SIST EN 12900:2013



EN 12900:2013 (E) 3 Foreword This document (EN 12900:2013) has been prepared by Technical Committee CEN/TC 113 “Heat pumps and air conditioning units”, the secretariat of which is held by AENOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2014 and conflicting national standards shall be withdrawn at the latest by January 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12900:2005. The main changes with respect to the previous edition are listed below: a) Clause 3 “Terms and definitions” is modified; b) the revised standard takes into account the application of CO2; c) the requirements on part load conditions according to Mandate M/488 are considered. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 12900:2013



EN 12900:2013 (E) 4 1 Scope This European Standard specifies the rating conditions, tolerances and the method of presenting manufacturer’s data for positive displacement refrigerant compressors. These include single stage compressors and single and two stage compressors using a means of fluid subcooling. This is required so that a comparison of different refrigerant compressors can be made. The data relate to the refrigerating capacity and power absorbed and include requirements for part-load operation where applicable. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 378-1:2008+A2:2012, Refrigerating systems and heat pumps — Safety and environmental requirements — Part 1: Basic requirements, definitions, classification and selection criteria EN 13771-1, Compressors and condensing units for refrigeration — Performance testing and test methods — Part 1: Refrigerant compressors ISO 817, Refrigerants — Designation system 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 378-1:2008+A2:2012 and the following apply. 3.1 positive displacement compressor compressor in which compression is obtained by changing the internal volume of the compression chamber [SOURCE: EN 378-1:2008+A2:2012, 3.4.6] 3.2 refrigerating capacity product of the low pressure mass flow of refrigerant through the compressor and the difference between the specific enthalpy of the refrigerant at the low pressure of the compressor inlet and the specific enthalpy of fluid entering the evaporator expansion device Note 1 to entry: This latter enthalpy is related to the stated fluid temperature under following pressure conditions: − for single-stage expansion cycles the compressor discharge pressure; − for multiple-stage expansion cycles the pressure (dew point temperature) at the corresponding compressor intermediate port. The refrigerant at the low compressor inlet is superheated above the suction dew point temperature to the stated value. Note 2 to entry: Condensing temperature is defined as saturated dew point temperature. SIST EN 12900:2013



EN 12900:2013 (E) 5 3.3 subcooling difference between the bubble point temperature of the refrigerant corresponding to the compressor discharge pressure and the temperature of the liquid refrigerant below the bubble point 3.4 suction gas superheat difference between the dew point temperature of the refrigerant corresponding to the compressor suction pressure and the suction gas temperature of the refrigerant at the compressor inlet 3.5 power absorbed  for externally driven compressors: the power at the compressor shaft  for motor compressors: the electrical power input at the motor terminals  for motor compressors with a specific means of factory assembled or factory specified frequency inverter for variable speed (part load) capacity regulation, the electrical power input at the inverter input terminals 3.6 coefficient of performance COPr ratio of refrigerating capacity to the power absorbed 3.7 subcritical operation operating condition with discharge pressure level below the critical pressure 3.8 transcritical operation operating condition with discharge pressure level above the critical pressure 3.9 part load operation for compressors with capacity control mechanism, part load is interpreted as operation with active capacity control at reduced capacity Note 1 to entry: On/off cycling of the compressor motor is not considered as capacity control in this context for declaration of part load performance. 3.10 fluid refrigerant liquid, gas or vapour including the state of appearance close to and above the critical pressure 3.11 evaporating temperature dew temperature corresponding to the suction pressure of the compressor 3.12 condensing temperature dew temperature corresponding to the discharge pressure of the compressor SIST EN 12900:2013



EN 12900:2013 (E) 6 4 Parameters for the presentation of performance data The parameters as shown in Table 1 to Table 4 shall be used for the presentation of the performance data. Table 1 — Parameters for the presentation of performance data with compressors used in standard applications Refrigerant Parameters Suction gas temperature (°C) or superheat (K) at the compressor inlet Ambient temperature around the compressor Compressor Application Halocarbons and hydrocarbons including refrigerant blends 32 °C 35 °C Household and similar refrigerators/ freezers 20 °C or 10 K Other applications R 744 (CO2) 32 °C Household and similar refrigerators/ freezers 10 K (30 °Ca ) Other applications R 717 5 K Any application using ammonia Other refrigerants As appropriate, to be clearly specified in performance data
a Reference point A5, Table 6. The refrigerating capacity shall not allow for any fluid subcooling for subcritical operation. For transcritical operation refrigeration capacity has to be related to the gas cooler outlet temperature and the compressor discharge pressure. If reference points mentioned in Table 5 to Table 7 fall inside the compressor application envelope, compressor performances shall be displayed at those rating conditions. For CO2 transcritical applications gas cooler outlet temperature shall be displayed. NOTE Tables 2 to 4 refer to economised cycles. SIST EN 12900:2013



EN 12900:2013 (E) 7 Table 2 — Parameters for the presentation of performance data with compressors using a specific means of factory asse
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.