Photobiological safety of lamps and lamp systems - Part 7: Light sources and luminaires primarily emitting visible radiation (IEC 62471-7:2023)

IEC 62471-7:2023 specifies an assessment of the photobiological safety of electrical light sources and luminaires in normal use as well as some basic product requirements. It applies to electrical light sources and luminaires that emit radiation predominantly in the visible spectral range (380 nm to 780 nm) and are used to illuminate spaces or objects or used for signalling.

Photobiologische Sicherheit von Lampen und Lampensystemen - Teil 7: Lichtquellen und Leuchten, die hauptsächlich sichtbare Strahlung aussenden (IEC 62471-7:2023)

Sécurité photobiologique des lampes et des appareils utilisant des lampes - Partie 7: Sources de lumière et luminaires qui émettent principalement un rayonnement visible (IEC 62471-7:2023)

L'IEC 62471-7:2023 spécifie une évaluation de la sécurité photobiologique des sources de lumière électriques et des luminaires en utilisation normale ainsi que des exigences fondamentales pour les produits. Elle s'applique aux sources de lumière électriques et aux luminaires qui émettent des rayonnements principalement dans le domaine spectral visible (380 nm à 780 nm) et qui sont utilisés pour éclairer des espaces ou des objets ou utilisés pour la signalisation.

Fotobiološka varnost sijalčnih sistemov - 7. del: Svetlobni viri in svetilke, ki oddajajo predvsem vidno sevanje (IEC 62471-7:2023)

Standard IEC 62471-7:2023 določa postopek ocenjevanja fotobiološke varnosti električnih svetlobnih virov in svetilk v normalnih pogojih uporabe in tudi nekatere osnovne zahteve za izdelke. Uporablja se za električne svetlobne vire in svetilke, ki oddajajo sevanje predvsem v vidnem spektralnem območju (380 nm do 780 nm) in se uporabljajo za osvetlitev prostorov ali predmetov oziroma za signalizacijo.

General Information

Status
Published
Public Enquiry End Date
31-Jul-2022
Publication Date
05-Apr-2023
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
29-Mar-2023
Due Date
03-Jun-2023
Completion Date
06-Apr-2023

Relations

Buy Standard

Standard
EN IEC 62471-7:2023 - BARVE
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN IEC 62471-7:2022
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 62471-7:2023
01-maj-2023
Fotobiološka varnost sijalčnih sistemov - 7. del: Svetlobni viri in svetilke, ki
oddajajo predvsem vidno sevanje (IEC 62471-7:2023)
Photobiological safety of lamps and lamp systems - Part 7: Light sources and luminaires
primarily emitting visible radiation (IEC 62471-7:2023)
Photobiologische Sicherheit von Lampen und Lampensystemen - Teil 7: Lichtquellen
und Leuchten, die hauptsächlich sichtbare Strahlung aussenden (IEC 62471-7:2023)
Sécurité photobiologique des lampes et des appareils utilisant des lampes - Partie 7:
Sources de lumière et luminaires qui émettent principalement un rayonnement visible
(IEC 62471-7:2023)
Ta slovenski standard je istoveten z: EN IEC 62471-7:2023
ICS:
29.140.01 Žarnice na splošno Lamps in general
SIST EN IEC 62471-7:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 62471-7:2023

---------------------- Page: 2 ----------------------
SIST EN IEC 62471-7:2023


EUROPEAN STANDARD EN IEC 62471-7

NORME EUROPÉENNE

EUROPÄISCHE NORM March 2023
ICS 29.140.01; 31.260

English Version
Photobiological safety of lamps and lamp systems - Part 7: Light
sources and luminaires primarily emitting visible radiation
(IEC 62471-7:2023)
Sécurité photobiologique des lampes et des appareils Photobiologische Sicherheit von Lampen und
utilisant des lampes - Partie 7: Sources de lumière et Lampensystemen - Teil 7: Lichtquellen und Leuchten, die
luminaires qui émettent principalement un rayonnement hauptsächlich sichtbare Strahlung aussenden
visible (IEC 62471-7:2023)
(IEC 62471-7:2023)
This European Standard was approved by CENELEC on 2023-03-23. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 62471-7:2023 E

---------------------- Page: 3 ----------------------
SIST EN IEC 62471-7:2023
EN IEC 62471-7:2023 (E)
European foreword
The text of document 34/1004/FDIS, future edition 1 of IEC 62471-7, prepared by IEC/TC 34 "Lighting"
was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN IEC 62471-7:2023.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2023-12-23
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2026-03-23
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 62471-7:2023 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standard indicated:
IEC 60432-1:1999 NOTE Approved as EN 60432-1:2000 (modified)
IEC 60432-1:1999/A1:2005 NOTE Approved as EN 60432-1:2000/A1:2005 (not modified)
IEC 60432-1:1999/A2:2011 NOTE Approved as EN 60432-1:2000/A2:2012 (not modified)
IEC 60432-2:1999 NOTE Approved as EN 60432-2:2000 (modified)
IEC 60432-2:1999/A1:2005 NOTE Approved as EN 60432-2:2000/A1:2005 (modified)
IEC 60432-2:1999/A2:2012 NOTE Approved as EN 60432-2:2000/A2:2012 (not modified)
IEC 60432-3:2012 NOTE Approved as EN 60432-3:2013 (not modified)
IEC 60598 (series) NOTE Approved as EN 60598 (series)
IEC 60598-2-13:2006 NOTE Approved as EN 60598-2-13:2006 (not modified) + A11:2021
IEC 60598-2-13:2006/A1:2011 NOTE Approved as EN 60598-2-13:2006/A1:2012 (not modified)
IEC 60598-2-13:2006/A2:2016 NOTE Approved as EN 60598-2-13:2006/A2:2016 (not modified)
IEC 60825-1:2014 NOTE Approved as EN 60825-1:2014 (not modified) + A11:2021
IEC 62031:2018 NOTE Approved as EN IEC 62031:2020 (not modified) + A11:2021
IEC 62035:2014 NOTE Approved as EN 62035:2014 (modified)
IEC 62035:2014/A1:2016 NOTE Approved as EN 62035:2014/A1:2019 (not modified)
2

---------------------- Page: 4 ----------------------
SIST EN IEC 62471-7:2023
EN IEC 62471-7:2023 (E)
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-845 - International Electrotechnical Vocabulary. - -
Lighting
IEC 60598-1 2020 Luminaires - Part 1: General requirements EN IEC 60598-1 2021
and tests
IEC 62471 (mod) 2006 Photobiological safety of lamps and lamp EN 62471 2008
systems
IEC 62471-5 2015 Photobiological safety of lamps and lamp EN 62471-5 2015
systems - Part 5: Image projectors

3

---------------------- Page: 5 ----------------------
SIST EN IEC 62471-7:2023

---------------------- Page: 6 ----------------------
SIST EN IEC 62471-7:2023




IEC 62471-7

®


Edition 1.0 2023-02




INTERNATIONAL



STANDARD




NORME


INTERNATIONALE
colour

inside










Photobiological safety of lamps and lamp systems –

Part 7: Light sources and luminaires primarily emitting visible radiation



Sécurité photobiologique des lampes et des appareils utilisant des lampes –

Partie 7: Sources de lumière et luminaires qui émettent principalement

un rayonnement visible















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 29.140.01; 31.260 ISBN 978-2-8322-6523-9




Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------
SIST EN IEC 62471-7:2023
– 2 – IEC 62471-7:2023 © IEC 2023
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 Optical radiation hazards of light sources and luminaires . 15
5 Actinic UV hazards exposure for skin and eye (200 nm to 400 nm) . 16
5.1 General . 16
5.2 Actinic UV assessment for light sources . 16
5.3 Actinic UV assessment for luminaires . 16
6 UV-A hazard assessment for the eye lens (315 nm to 400 nm) . 17
6.1 General . 17
6.2 UV-A light source and luminaire assessment . 17
7 Retinal blue light hazard assessment (300 nm to 700 nm) . 18
7.1 General . 18
7.2 Blue light hazard assessment for light sources . 18
7.3 Blue light hazard assessment for luminaires . 18
7.4 Retinal blue light hazard assessment – Small source (300 nm to 700 nm) . 21
8 Retinal thermal hazard assessment (380 nm to 1 400 nm) . 21
8.1 General . 21
8.2 Retinal thermal hazard for light source assessment . 21
8.3 Retinal thermal hazard assessment for luminaire . 22
8.4 Retinal thermal hazard assessment – Weak visual stimulus (780 nm to
1 400 nm) . 22
9 Infrared hazard assessment for the eye (780 nm to 3 000 nm) . 22
9.1 General . 22
9.2 Light source and luminaire assessment . 23
10 Thermal hazard assessment for the skin (380 nm to 3 000 nm) . 23
10.1 General . 23
10.2 Light source and luminaire assessment . 23
Annex A (informative) Information on emission limits for light sources and luminaires . 24
Annex B (informative) Information on UV hazards exposure (200 nm to 400 nm) . 26
Annex C (informative) Information on retinal hazards (300 nm to 1 400 nm) . 27
Annex D (informative) Information on IR-hazard (380 nm to 3 000 nm) . 29
Annex E (informative) Example of a complete luminaire assessment of a LED office
luminaire . 30
E.1 UV assessment . 30
E.1.1 Actinic UV (Clause 5) . 30
E.1.2 UV-A (Clause 6) . 30
E.2 Retinal hazard assessment . 30
E.2.1 Blue light hazard (Clause 7). 30
E.2.2 Thermal retinal hazard (Clause 8) . 30
E.3 Infrared radiation hazard assessment for the eye (780 nm to 3 000 nm)
(Clause 9) . 30
E.4 Thermal hazard assessment for the skin (380 nm to 3 000 nm) (Clause 10) . 30
Bibliography . 31

---------------------- Page: 8 ----------------------
SIST EN IEC 62471-7:2023
IEC 62471-7:2023 © IEC 2023 – 3 –
Figure C.1 – Flowchart to define worst-case (minimum) time to dose for the
assessment of the blue light hazard L as a function of application-specific conditions
B
of luminaires . 28

Table 1 – Optical radiation hazards covered in this document . 15
Table 2 – Application-related blue light radiance emission limits at assessment
distances for luminaires . 20

---------------------- Page: 9 ----------------------
SIST EN IEC 62471-7:2023
– 4 – IEC 62471-7:2023 © IEC 2023
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS –

Part 7: Light sources and luminaires primarily emitting visible radiation

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
IEC 62471-7 has been prepared by IEC technical committee 34: Lighting. It is an International
Standard.
The text of this International Standard is based on the following documents:
Draft Report on voting
34/1004/FDIS 34/1011/RVD

Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.

---------------------- Page: 10 ----------------------
SIST EN IEC 62471-7:2023
IEC 62471-7:2023 © IEC 2023 – 5 –
A list of all parts in the IEC 62471 series, published under the general title Photobiological
safety of lamps and lamp systems, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The "colour inside" logo on the cover page of this document indicates that it
contains colours which are considered to be useful for the correct understanding of its
contents. Users should therefore print this document using a colour printer.

---------------------- Page: 11 ----------------------
SIST EN IEC 62471-7:2023
– 6 – IEC 62471-7:2023 © IEC 2023
INTRODUCTION
The wording "lamps and lamp systems" is used in the title of the IEC 62471 series. However,
in the title of this Part 7, the wording "light sources and luminaires" is used. The reason for this
is that due to the introduction of new LED technologies the characteristics of the light-generating
components have changed. Therefore, the terms "electrical light source" and "luminaire" are
nowadays used in TC 34 instead of "lamp" and "lamp system".
"Electric light source" is the generic term for products which produce light; the term "lamp" (light
source with a lamp cap-holder system) is thereby included.
"Luminaire" is the basic term (see IEC 60050-845:2020, 845-30-001) for a product that includes
all necessary accessories and describes a device that distributes, filters, or transforms the light
produced from at least one source of optical radiation and which includes, except the sources
themselves, all the parts necessary for fixing and protecting the sources and, where necessary,
circuit auxiliaries together with the means for connecting them to the power supply.
When luminaires are designed and constructed in accordance with the requirements of this
document, they are presumed to function safely under normal use and present a photobiological
hazard. Conformity of luminaires can be verified by application of the assessment procedures
described in this document.
The light sources can be interchangeable or an integral part of the luminaire. If the light source
is an integral part of the luminaire, the luminaire can also be considered a light source system
(corresponding to a lamp system).
Most electrical light sources and luminaires within the scope of this document will not present
a photobiological hazard due to their spectra, their light distribution, the light levels, and the
natural aversion responses – people do not usually stare into bright sources, for example. There
remain, however, some light sources and luminaires, which have the potential to pose adverse
health effects from the emitted optical radiation. Exposure limits for a range of photobiological
hazards associated with broad-band optical radiation sources have been developed and
published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP).
This document introduces a new assessment procedure to address the various lighting
applications in which the intended purpose is the illumination of objects and scenes and in
signalling applications. This new approach uses revised time bases (and emission limits) related
to the intentional or unintentional direct viewing of the luminaire and assessment distances
depending on application. These emission limits are based on the exposure limits of the
ICNIRP.
In this document, a complete procedure is used to cover all photobiological hazards in the range
of 200 nm to 3 000 nm as implemented in IEC 62471.
This procedure, based on a product- and application-related assessment, leads to a pass/fail
result for a specific product in that given application.

---------------------- Page: 12 ----------------------
SIST EN IEC 62471-7:2023
IEC 62471-7:2023 © IEC 2023 – 7 –
PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS –

Part 7: Light sources and luminaires primarily emitting visible radiation



1 Scope
This part of IEC 62471 specifies an assessment of the photobiological safety of electrical light
sources and luminaires in normal use as well as some basic product requirements. It applies to
electrical light sources and luminaires that emit radiation predominantly in the visible spectral
range (380 nm to 780 nm) and are used to illuminate spaces or objects or used for signalling.
Electrical light sources and luminaires designed for emitting radiation in the visible range can
also emit radiation in the ultraviolet (UV) and infrared (IR) regions depending on the technology
applied. This document, therefore, includes the blue light, thermal, UV, UV-A, IR and skin
thermal hazards for the optical radiation over the wavelength range 200 nm to 3 000 nm.
Electrical light sources and luminaires that are designed to predominantly emit radiation outside
the visible spectral range (380 nm to 780 nm) (e.g. UV sterilizers or industrial heaters) are not
within the scope of this document.
Electrical light sources for illumination are considered to emit continuous light for
photobiological safety assessment. This includes light sources with pulse width modulation
(PWM).
This document can also be applied to the illumination function of multi-function luminaires which
can simultaneously perform functions other than illumination. Other standards can be applied
to the non-illumination function(s).
This document can also be applied to electric light sources and luminaires which emit visible
light, when there is no limitation on the presence of people (e.g. horticulture).
This document can also be applied to laser products used for illumination and signalling when
the conditions of IEC 60825-1:2014, 4.4 are met.
NOTE See IEC 60825-1:2014 for other requirements of laser products.
This document is intended to be referenced by product standards for the assessment of
applicable photobiological safety aspects. Additional details for the photobiological safety
assessment and data presentation are specified in the product standards.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-845, International Electrotechnical Vocabulary (IEV) – Part 845: Lighting, available
at http://www.electropedia.org
IEC 60598-1:2020, Luminaires – Part 1: General requirements and tests
IEC 62471:2006, Photobiological safety of lamps and lamp systems

---------------------- Page: 13 ----------------------
SIST EN IEC 62471-7:2023
– 8 – IEC 62471-7:2023 © IEC 2023
IEC 62471-5:2015, Photobiological safety of lamps and lamp systems – Part 5: Image projectors
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62471,
IEC 60050-845 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
• IEC Electropedia: available at https://www.electropedia.org/
• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
blue light hazard
BLH
potential for a photochemically induced retinal injury (photic maculopathy) resulting from optical
radiation exposure at wavelengths primarily between 400 nm and 500 nm
Note 1 to entry: This damage mechanism dominates over the thermal damage mechanism for exposure durations
exceeding 10 s.
Note 2 to entry: The weighting function extends into the UV-A for persons without a normal UV-A absorbing lens.
[SOURCE: IEC 60050-845:2020, 845-26-055, modified – In Note 2 to entry "action spectrum"
has been replaced with "weighting function".]
3.2
exposure limit
maximum level of exposure of a surface, usually the eye or skin, that is not expected to result
in adverse biological effects
Note 1 to entry: Exposure limits for human safety of optical radiation, H , are normally recommended by the
L
International Commission on Non-Ionizing Radiation Protection (ICNIRP).
Note 2 to entry: Exposure limits are often based on irradiance (e.g. for the skin), but where relevant, can also be
based on radiance (e.g. the blue light hazard of extended sources).
[SOURCE: IEC 60050-845:2020, 845-26-072]
3.3
emission limit
specified maximum emission level of a source of optical radiation that is not expected to result
in adverse biological effect for a specific application
Note 1 to entry: Evaluation of sources to the emission limits can be based upon reasonably foreseeable conditions
of time-weighted exposure. It incorporates both the concept of exposure duration and exposure distance and is
derived from exposure limits.
[SOURCE: IEC 60050-161:1990, 161-03-12, modified – The domain has been deleted, the
definition has been adapted in relation to optical radiation and the Note to entry has been
added.]

---------------------- Page: 14 ----------------------
SIST EN IEC 62471-7:2023
IEC 62471-7:2023 © IEC 2023 – 9 –
3.4
field of view
FOV
solid angle as "seen" by the detector (acceptance angle), e.g. of a radiometer or
spectroradiometer, out of which the detector receives radiation
Note 1 to entry: The field of view should not be confused with the angular subtense of the apparent source, α.
Note 2 to entry: A plane angle is sometimes used to describe a circular symmetric solid angle field of view.
Note 3 to entry: The field of view is expressed in steradian (sr).
[SOURCE: IEC 60050-845:2020, 845-25-077]
3.5
illuminance
E
v
density of incident luminous flux with respect to area at a point on a real or imaginary surface

v
E =
v
dA

where Φ is luminous flux and A is the area on which the luminous flux is incident
v
Note 1 to entry: Illuminance can be derived from the spectral irradiance distribution by

E = KE (λ·) V(λ·) d(λ)
v me,λ

0

where K is maximum luminous efficacy, E (λ) is the spectral irradiance at wavelength λ and V(λ) is spectral
m e,λ
luminous efficiency.
Note 2 to entry: The corresponding radiometric quantity is "irradiance". The corresponding quantity for photons is
"photon irradiance".
−2
Note 3 to entry: The illuminance is expressed in lux (lx = lm · m ).
[SOURCE: IEC 60050-845:2020, 845-21-060]
3.6
infrared radiation
IRR
optical radiation for which the wavelengths are longer than those for visible radiation
Note 1 to entry: For infrared radiation, the range between 780 nm and 1 mm is commonly subdivided into:
IR-A: 780 nm to 1 400 nm, or 0,78 μm to 1,4 μm;
IR-B: 1,4 μm to 3,0 μm;
IR-C: 3 μm to 1 mm.
Note 2 to entry: A precise border between "visible radiation" and "infrared radiation" cannot be defined because
visual sensation at wavelengths greater than 780 nm can be experienced.
Note 3 to entry: In some applications the infrared spectrum has also been divided into "near", "middle", and "far"
infrared; however, the borders necessarily vary with the application.
[SOURCE: IEC 60050-845:2020, 845-21-004]

---------------------- Page: 15 ----------------------
SI
...

SLOVENSKI STANDARD
oSIST prEN IEC 62471-7:2022
01-julij-2022
Fotobiološka varnost sijalčnih sistemov - 7. del: Svetlobni viri in svetilke, ki
oddajajo predvsem vidno sevanje
Photobiological safety of lamps and lamp systems - Part 7: Light sources and luminaires
primarily emitting visible radiation
Sécurité photobiologique des lampes et des appareils utilisant des lampes - Partie 7:
Sources de lumière et luminaires qui émettent principalement un rayonnement visible
Ta slovenski standard je istoveten z: prEN IEC 62471-7:2022
ICS:
29.140.01 Žarnice na splošno Lamps in general
oSIST prEN IEC 62471-7:2022 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 62471-7:2022

---------------------- Page: 2 ----------------------
oSIST prEN IEC 62471-7:2022
34/916/CDV

COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 62471-7 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2022-05-20 2022-08-12
SUPERSEDES DOCUMENTS:
34/885/CD, 34/907A/CC

IEC TC 34 : LIGHTING
SECRETARIAT: SECRETARY:
United Kingdom Mr Petar Luzajic
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

TC 76
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.

TITLE:
Photobiological safety of lamps and lamp systems - Part 7: Light sources and luminaires
primarily emitting visible radiation

PROPOSED STABILITY DATE: 2025

NOTE FROM TC/SC OFFICERS:


Copyright © 2022 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, or any part of it, for
any other purpose without permission in writing from IEC.

---------------------- Page: 3 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 2 34/916/CDV

1 CONTENTS
2 FOREWORD. 3
3 INTRODUCTION . 5
4 1 Scope . 6
5 2 Normative references . 6
6 3 Terms and definitions . 7
7 4 Optical radiation hazards of light sources and luminaires . 13
8 5 Actinic UV hazards exposure for skin and eye (200 nm to 400 nm) . 14
9 5.1 General . 14
10 6 UV-A hazard assessment for the eye lens (315 nm to 400 nm) . 15
11 6.1 General . 15
12 6.2 UV-A light source and luminaire assessment . 15
13 7 Retinal blue light hazard assessment (300 nm to 700 nm) . 15
14 7.1 General . 15
15 7.2 Blue light hazard assessment for light sources . 15
16 7.3 Blue light hazard assessment for luminaires . 16
17 7.4 Retinal blue light hazard assessment - small source (300 nm to 700 nm) . 18
18 8 Retinal thermal hazard assessment (380 nm to 1 400 nm) . 18
19 8.1 General . 18
20 8.2 Retinal thermal hazard for light source assessment . 18
21 8.3 Retinal thermal hazard assessment for luminaire . 19
22 8.4 Retinal thermal hazard assessment – weak visual stimulus (780 nm to
23 1 400 nm) . 19
24 9 Infrared radiation hazard assessment for the eye (780 nm to 3 000 nm) . 19
25 9.1 General . 19
26 9.2 Light source and luminaire assessment . 19
27 10 Thermal hazard assessment for the skin (380 nm to 3 000 nm) . 20
28 10.1 General . 20
29 10.2 Light source and luminaire assessment . 20
30 Annex A (informative) Information on emission limits for light sources and luminaires . 21
31 Annex B (informative) Information on UV hazards exposure (200 nm to 400 nm) . 23
32 Annex C (informative) Information on retinal hazards (300 nm to 1 400 nm) . 24
33 Annex D (informative) Information on IR-hazard (380 nm to 3 000 nm) . 26
34 Annex E (informative) Example of a complete luminaire assessment of a LED office
35 luminaire . 27
36 E.1 UV assessment . 27
37 E.1.1 Actinic UV (Clause 5) . 27
38 E.1.2 UV-A (Clause 6) . 27
39 E.2 Retinal hazard assessment . 27
40 E.2.1 Blue light hazard (Clause 7) . 27
41 E.2.2 Thermal retinal hazard (Clause 8) . 27
42 E.3 IR assessment (Clause 9) . 27
43 Bibliography . 28
44
45
46

---------------------- Page: 4 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 3 34/916/CDV

47 INTERNATIONAL ELECTROTECHNICAL COMMISSION
48 ____________
49
50 PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS –
51
52 Part 7: Light sources and luminaires primarily emitting visible radiation
53
54
55
56 FOREWORD
57 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
58 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
59 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
60 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
61 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
62 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
63 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
64 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
65 Standardization (ISO) in accordance with conditions determined by agreement between the two o rganizations.
66 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
67 consensus of opinion on the relevant subjects since each technical committee has representation from all
68 interested IEC National Committees.
69 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
70 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
71 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
72 misinterpretation by any end user.
73 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
74 transparently to the maximum extent possible in their national and regional publications. Any divergence between
75 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
76 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
77 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
78 services carried out by independent certification bodies.
79 6) All users should ensure that they have the latest edition of this publication.
80 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
81 members of its technical committees and IEC National Committees for any personal injury, proper ty damage or
82 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
83 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
84 Publications.
85 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
86 indispensable for the correct application of this publication.
87 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
88 rights. IEC shall not be held responsible for identifying any or all such patent rights.
89 IEC 62471-7 has been prepared by IEC technical committee 34: Lighting. It is an International
90 Standard.
91 The text of this International Standard is based on the following documents:
Draft Report on voting
34/XX/FDIS 34/XX/RVD
92
93 Full information on the voting for its approval can be found in the report on voting indicated in
94 the above table.
95 The language used for the development of this International Standard is English.
96 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
97 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available

---------------------- Page: 5 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 4 34/916/CDV

98 at https://www.iec.ch/members_experts/refdocs. The main document types developed by IEC
99 are described in greater detail at https://www.iec.ch/standardsdev/publications.
100 A list of all parts in the IEC 62471 series, published under the general title Photobiological
101 safety of lamps and lamp systems, can be found on the IEC website.
102 The committee has decided that the contents of this document will remain unchanged until the
103 stability date indicated on the IEC website under webstore.iec.ch in the data related to the
104 specific document. At this date, the document will be
105 • reconfirmed,
106 • withdrawn,
107 • replaced by a revised edition, or
108 • amended.

---------------------- Page: 6 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 5 34/916/CDV

109 INTRODUCTION
110 The terms "lamps and lamp systems" are used in the title of the IEC 62471 series however, in
111 the title of this Part 7, the terms "light sources and luminaires" are used. The reason for this is
112 that due to the introduction of new LED technologies the characteristics of the light-generating
113 components have changed. Therefore, the terms "electrical light sources" and "luminaires" are
114 nowadays used in TC 34 instead of "lamps and lamp systems". "Electric light source" is the
115 generic term for products which are producing light; the term "lamp" (light source with a lamp
116 cap-holder system) is thereby included. The terms "light sources and luminaires" are used in
117 this Part 7, but in the other parts of the IEC 62471 series, the terms "lamps and lamp systems"
118 are used.
119 "Luminaire" is the basic term (see IEC 60050-845:2020), for a product that includes all
120 necessary accessories and describes a device that distributes, filters, or transforms the light
121 produced from at least one source of optical radiation and which includes, except the sources
122 themselves, all the parts necessary for fixing and protecting the sources and, where necessary,
123 circuit auxiliaries together with the means for connecting them to the power supply.
124 When luminaires are designed and constructed in accordance with the requirements of this
125 document, they are presumed to function safely, from a photobiological safety perspective,
126 under normal use and not to present a photobiological hazard to persons or the environment.
127 Conformity of luminaires is verified by performing the evaluation of this document with the
128 specified acceptable light sources (one or more).
129 The light sources can be interchangeable or an integral part of the luminaire. If the light source
130 is an integral part of the luminaire, the luminaire could also be considered a light source system
131 (corresponding to a lamp system).
132 Most electrical light sources and luminaires within the scope of this document will not present
133 a photobiological hazard due to the spectra used, the light levels, and the natural aversion
134 responses – people do not usually stare into high luminance sources, for example. Normally
135 light sources and luminaires are safe and do not pose photobiological hazards except under
136 unusual exposure conditions. There remain, however, some light sources and luminaires, which
137 have the potential to pose adverse health effects from the emitted optical radiation. Exposure
138 limits for a range of photobiological hazards associated with broad-band optical radiation
139 sources have been developed and published by the International Commission on Non-Ionizing
140 Radiation Protection (ICNIRP).
141 This document introduces a new assessment procedure to address the various lighting
142 applications in which the intended purpose is the illumination of objects and scenes. This new
143 approach uses revised time bases related to the intentional or unintentional view into the
144 luminaire (leading to emission limits) and assessment distances depending on application.
145 These emission limits are based on the exposure limits of ICNIRP.
146 In this document, a complete procedure is used to cover all photobiological hazards in the range
147 of 200 nm to 3 000 nm as implemented in IEC 62471.
148 This procedure, based on a product- and application-related assessment, leads to a single
149 pass/fail result for a specific product in that given application.
150
151
152
153

---------------------- Page: 7 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 6 34/916/CDV

154
155 PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS –
156 Part 7: Light sources and luminaires primarily emitting visible radiation
157
158
159
160 1 Scope
161 This part of IEC 62471 specifies an assessment of the photobiological safety of electrical light
162 sources and luminaires in normal use. The assessment is applied for electrical light sources
163 and luminaires that emit radiation predominantly in the visible spectral range (380 nm to
164 780 nm) and are used to illuminate spaces or objects or used for signalling.
165 Electrical light sources and luminaires designed for emitting radiation in the visible range can
166 also emit radiation in the ultraviolet (UV) and infrared (IR) regions depending on the technology
167 applied. The photobiological safety assessment in this document, therefore, includes the blue
168 light-, thermal-, UV-, UV-A-, IR- and skin thermal- hazards (includes optical radiation over the
169 wavelength range 200 nm to 3 000 nm).
170 Electrical light sources and luminaires that are designed to predominantly emit radiation outside
171 the visible spectral range (380 nm to 780 nm) (e.g. UV sterilizers or industrial heaters) are not
172 within the scope of this document.
173 Electrical light sources for illumination are considered to emit continuous light (pulse width
174 modulation (PWM) are included), therefore emission levels of continuous light (continuous wave
175 (CW)) are applied.
176 When there is no limitation on the presence of people, this document can be applied to electrical
177 light sources and luminaires which emit visible light, but the main purpose is not illumination or
178 signalling (e.g. horticulture).
179 This document also applies to laser products when the conditions of IEC 60825-1:2014, 4.4 are
180 met and they are used for illumination or signalling.
181 Note: See IEC 60825-1:2014 for other requirements of laser products.
182 This document is intended to be referenced by TC 34 product standards for the assessment of
183 applicable photobiological safety aspects. Additional details for the photobiological safety
184 assessment and data presentation are specified in the product standards.
185 2 Normative references
186 The following documents are referred to in the text in such a way that some or all of their content
187 constitutes requirements of this document. For dated references, only the edition cited applies.
188 For undated references, the latest edition of the referenced document (including any
189 amendments) applies.
190 IEC 60598-1:2020, Luminaires — Part 1: General requirements and tests
191 IEC 62471:2006, Photobiological safety of lamps and lamp systems
192 IEC 62504, General lighting — Light emitting diode (LED) products and related equipment —
193 Terms and definitions

---------------------- Page: 8 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 7 34/916/CDV

194 3 Terms and definitions
195 For the purposes of this document, the terms and definitions given in IEC 62471 and IEC 62504
196 apply with the following additions.
197 ISO and IEC maintain terminology databases for use in standardization at the following
198 addresses:
199 • IEC Electropedia: available at https://www.electropedia.org/
200 • ISO Online browsing platform: available at https://www.iso.org/obp
201 3.1
202 blue light hazard
203 BLH
204 potential for a photochemically induced retinal injury (photic maculopathy) resulting from optical radiation
205 exposure at wavelengths primarily between 400 nm and 500 nm.
206 Note 1 to entry: This damage mechanism dominates over the thermal damage mechanism for exposure duration exceeding
207 10 s.
208 Note 2 to entry: The action spectrum extends into the UV-A for persons without a normal UV-A absorbing lens.
209 [SOURCE: IEC 60050-845:2020, 845-26-055.]
210 3.2
211 exposure limit
212 maximum level of exposure of a surface, usually the eye or skin, that is not expected to result in adverse
213 biological effects
214 Note 1 to entry: Exposure limits for human safety of optical radiation, HL, are normally recommended by the International
215 Commission on Non-Ionizing Radiation Protection (ICNIRP).
216 Note 2 to entry: Exposure limits are often based on irradiance (e.g., for the skin), but where relevant, can also be based on
217 radiance (e.g., the blue light hazard of extended sources).
218 [SOURCE: IEC 60050-845:2020, 845-26-072.]
219 3.3
220 emission limit
221 specified maximum emission level of a source of optical radiation that is not expected to result in adverse
222 biological effect for a specific application
223 Note to entry: Evaluation of sources to the emission limits can be based upon reasonably foreseeable conditions of time-weighted
224 exposure. It incorporates both the concept of exposure duration and exposure distance and is derived from exposure limits.
225 [SOURCE: IEC 60050-161:1990, 161-03-012, modified – The domain has been deleted, the definition
226 has been adapted in relation to optical radiation and the Note to entry has been added.]
227 3.4
228 field of view
229 FOV
230 solid angle as "seen" by the detector (acceptance angle), e.g. of a radiometer or spectroradiometer, out
231 of which the detector receives radiation
232 Note 1 to entry: The field of view should not be confused with the angular subtense of the apparent source, α.
233 Note 2 to entry: A plane angle is sometimes used to describe a circular symmetric solid angle field of view.
234 Note 3 to entry: The field of view is expressed in steradian (sr).
235 [SOURCE: IEC 60050-845:2020, 845-25-077.]
236 3.5
237 illuminance
238 E
v
239 density of incident luminous flux with respect to area at a point on a real or imaginary surface
𝑑𝛷
𝑣
240 𝐸 =
V
𝑑𝐴
241 where Φ is luminous flux and A is the area on which the luminous flux is incident
v

---------------------- Page: 9 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 8 34/916/CDV

242 Note 1 to entry: Illuminance can be derived from the spectral irradiance distribution by

243 𝐸 = 𝐾 ∫ 𝐸 (λ) · 𝑉(λ) · 𝑑(λ)
v m e,λ
0
244 where K is maximum luminous efficacy, E (λ) is the spectral irradiance at wavelength λ and V(λ) is spectral luminous efficiency.
m e,λ
245 Note 2 to entry: The corresponding radiometric quantity is "irradiance". The corresponding quantity for photons is "photon
246 irradiance".
−2
247 Note 3 to entry: The illuminance is expressed in lux (lx = lm · m ).
248 [SOURCE: IEC 60050-845:2020, 845-21-060.]
249 3.6
250 infrared radiation
251 IRR
252 optical radiation for which the wavelengths are longer than those for visible radiation
253 Note 1 to entry: For infrared radiation, the range between 780 nm and 1 mm is commonly subdivided into:
254  IR-A: 780 nm to 1 400 nm, or 0,78 μm to 1,4 μm;
255  IR-B: 1,4 μm to 3,0 μm;
256  IR-C: 3 μm to 1 mm.
257 Note 2 to entry: A precise border between "visible radiation" and "infrared radiation" cannot be defined because visual sensation
258 at wavelengths greater than 780 nm can be experienced.
259 Note 3 to entry: In some applications the infrared spectrum has also been divided into "near," "middle," and "far" infrared; however,
260 the borders necessarily vary with the application.
261 [SOURCE: IEC 60050-845:2020, 845-21-004.]
262 3.7
263 irradiance
264 density of incident radiant flux with respect to area at a point on a real or imaginary surface
𝑑𝛷
265 𝐸 =
𝑑𝐴
266 where Φe is radiant flux and A is the area on which the radiant flux is incident
267 Note 1 to entry: The corresponding photometric quantity is "illuminance". The corresponding quantity for photons is "photon
268 irradiance".
−2
269 Note 2 to entry: The irradiance is expressed in watt per square metre (W · m ).
270 [SOURCE: IEC 60050-845:2020, 845-21-053.]
271 3.8
272 electric light source
273 primary light source with the means for connecting to the power supply and usually designed to
274 be incorporated into a luminaire
275 Note 1 to entry: In IEC standards, “light source” and "lamp" are commonly used with the same meaning.
276 Note 2 to entry: An electric light source can be an electric lamp, or LED module designed to be connected by terminals, connectors,
277 or similar devices.
278 Note 3 to entry: For products that have the same physical characteristics as electric light sources for general lighting but that are
279 built to emit optical radiation (IEV 845-21-002) mainly in the IR or UV spectrum, the term "IR lamp" or "UV lamp" is often used.
280 [SOURCE: IEC 60050-845:2020, 845-27-004, modified – In Note 1 to entry, "and "lamp" are" has been
281 added and Note 3 to entry has been added.]
282 3.9
283 luminaire
284 apparatus which distributes, filters or transforms the light transmitted from at least one source of optical
285 radiation and which includes, except the sources themselves, all the parts necessary for fixing and
286 protecting the sources and, where necessary, circuit auxiliaries together with the means for connecting
287 them to the power supply
288 Note 1 to entry: A luminaire with integral non-replaceable lamps is regarded as a luminaire, except that the tests are not applied
289 to the integral lamp or integral self-ballasted lamp.
290 Note 2 to entry: In this document, evaluation of a luminaire is understood to mean evaluation of a luminaire with the intended
291 normal use of the specified light sources or with the light sources installed. For the selection of light sources IEC 60598-1:2020,
292 Annex B shall be served.

---------------------- Page: 10 ----------------------
oSIST prEN IEC 62471-7:2022
IEC CDV 62471-7 © IEC 2022 9 34/916/CDV

293 [SOURCE: IEC 60050-845:2020, 845-30-001, modified – The Notes to entry have been added.]
294 3.10
295 optical radiation
296 electromagnetic radiation at wavelengths between the region of transition to X-rays (λ ≈ 1 nm) and the
297 region of transition to radio waves (λ ≈ 1 mm)
298 Note 1 to entry: Ultraviolet radiation in the wavelength range below 180 nm (vacuum UV) is strongly absorbed by the oxygen
299 in air. For the purposes of this document the wavelength band of optical radiation is limited to wavelengths greater than 200 nm.
300 Further, the eye transmits optical radiation to the retina between 300 nm and 1 400 nm. Thus, this wavelength range requires
301 special consideration in determining the photobiological safety of the retina.
302 [SOURCE: IEC 60050-845:2020, 845-21-002, modified – The note to entry has been added.]
303 3.11
304 radiance
305 L
e
306 L
307 density of radiant intensity with respect to projected area in a specified direction at a specified
308 point on a real or imaginary surface, expressed by
𝑑𝐼 1
𝑒
309 𝐿 = ·
𝑒
𝑑𝐴 𝑐𝑜𝑠𝛼
310 where I is radiant intensity, A is area, and  is the angle between the normal to the surface at
e
311 the specified point and the specified direction
312 Note 1 to entry: In a practical sense, the definition of radiance can be thought of as dividing a real or imaginary surface into an
313 infinite number of infinitesimally small surfaces which can be considered as point sources, each of which has a specific radiant
314 intensity, I , in the specified direction. The radiance of the surface is then the integral of these radiance elements over the whole
e
315 surface.
316 The equation in the definition can mathematically be interpreted as a derivative (i.e., a rate of change of radiant intensity with
̅
317 projected area) and could alternatively be rewritten in terms of the average radiant intensity 𝐼 as:
𝑒
̅
𝐼 1
𝑒
318 𝐿 = lim · ·
𝑒
𝐴→0 𝐴 𝑐𝑜𝑠𝛼
319 Hence, radiance is often considered as a quotient of averaged quantities; the area, A, should be small enough that uncertainties
𝐼̅ 1
𝑒
320 due to variations in radiant intensity within that area are negligible, otherwise, the quotient 𝐿 = · gives the average
𝑒
𝐴 𝑐𝑜𝑠𝛼
321 radiance and the specific measurement conditions have to be reported with the result.
322 Note 2 to entry: For a surface being irradiated, an equivalent formula in terms of irradiance, E , and solid angle, , is
e
𝑑𝐸 1
𝑒
323 𝐿 = · , where  is the angle between the normal to the surface being irradiated and the direction of irradiation. This
𝑒
𝑑𝛺 𝑐𝑜𝑠𝜃
324 form is useful when the source has no surface (e.g., the sky, the plasma of a discharge).
𝑑
𝑒
325 Note 3 to entry: An equivalent formula is 𝐿 = , where  is radiant flux and G is geometric extent.
𝑒 e
𝑑𝐺
326 Note 4 to entry: Radiant flux can be obtained by integrating radiance over projected area, Acos , and solid angle,  :
327  = ∬ 𝐿 · 𝑐𝑜𝑠𝛼 · 𝑑𝐴 · 𝑑
𝑒 𝑒
2
328 Note 5 to entry: Since the optical extent, expressed by G · n , where G is geometric extent and n is refractive index, is invariant,
−2
329 the quantity expressed by Le · n is also invariant along the path of the beam if the losses by absorption, reflection and diffusion
330 are taken as 0. That quantity is called "basic radiance".
331 Note 6 to entry: The equation in the definition can also be described as a function of radiant flux,  . In this case, it is
e
332 mathemati
...

Questions, Comments and Discussion