Requirements for Lightning Protection System Components (LPSC) - Part 4: Requirements for fasteners

This International Standard specifies requirements and tests for metallic and non-metallic conductor fasteners that are used in conjunction with the air termination system and down conductors and for fixing of conductor fasteners to the fabric / membrane / gravel roofing of structures is not covered by this standard due to the vast number and types used in modern day construction.

Blitzschutzsystembauteile (LPSC) - Teil 4: Anforderungen an Leitungshalter

Composants de Système de Protection contre la Foudre (CSPF) - Partie 4: Exigences pour les fixations de conducteur

La CEI 62561-4:2010 spécifie les exigences et les essais pour les supports métalliques et non métalliques de conducteur qui sont employés avec des dispositifs de capture, des conducteurs de descente et des prises de terre. La présente norme ne traite pas la fixation des supports sur les structures d'édifice/membrane/toiture gravillonnée en raison des nombreuses solutions modernes de construction. Les CSPF peuvent aussi être employés dans des atmosphères dangereuses. Dans ce cas, il convient de veiller à ce que les caractéristiques des composants soient en adéquation avec ces conditions.

Zahteve za elemente sistema za zaščito pred strelo (LPSC) - 4. del: Zahteve za pritrdilne elemente (IEC 62561-4:2010, spremenjen)

Ta mednarodni standard določa zahteve in preskuse za kovinske in nekovinske pritrdilne elemente strelovodov, ki se uporabljajo v povezavi s strelovodno zaščito in spodnjim delom strelovoda, preskusov za pritrjevanje pritrdilnih elementov strelovodov na tkane/membranske/peščene strehe zgradb zaradi velikega števila in vrst, ki se uporabljajo v sodobni gradnji, pa ta standard ne zajema.

General Information

Status
Withdrawn
Public Enquiry End Date
27-Feb-2010
Publication Date
11-Apr-2011
Withdrawal Date
09-Nov-2020
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
10-Nov-2020
Due Date
03-Dec-2020
Completion Date
10-Nov-2020

Relations

Buy Standard

Standard
EN 62561-4:2011
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62561-4:2011
01-maj-2011
1DGRPHãþD
SIST EN 50164-4:2008
=DKWHYH]DHOHPHQWHVLVWHPD]D]DãþLWRSUHGVWUHOR /36& GHO=DKWHYH]D
SULWUGLOQHHOHPHQWH ,(&VSUHPHQMHQ
Requirements for Lightning Protection System Components (LPSC) - Part 4:
Requirements for fasteners
Blitzschutzsystembauteile (LPSC) - Teil 4: Anforderungen an Leitungshalter
Composants de Système de Protection contre la Foudre (CSPF) - Partie 4: Exigences
pour les fixations de conducteur
Ta slovenski standard je istoveten z: EN 62561-4:2011
ICS:
91.120.40 =DãþLWDSUHGVWUHOR Lightning protection
SIST EN 62561-4:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62561-4:2011

---------------------- Page: 2 ----------------------

SIST EN 62561-4:2011

EUROPEAN STANDARD
EN 62561-4

NORME EUROPÉENNE
March 2011
EUROPÄISCHE NORM

ICS 29.020; 91.120.40 Supersedes EN 50164-4:2008


English version


Lightning protection system components (LPSC) -
Part 4: Requirements for conductor fasteners
(IEC 62561-4:2010, modified)


Composants de système de protection Blitzschutzsystembauteile (LPSC) -
contre la foudre (CSPF) - Teil 4: Anforderungen an Leitungshalter
Partie 4: Exigences pour les fixations de (IEC 62561-4:2010, modifiziert)
conducteur
(CEI 62561-4:2010, modifiée)




This European Standard was approved by CENELEC on 2011-02-21. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62561-4:2011 E

---------------------- Page: 3 ----------------------

SIST EN 62561-4:2011
EN 62561-4:2011 - 2 -
Foreword
The text of the International Standard IEC 62561-4:2010, prepared by IEC TC 81, Lightning protection,
together with common modifications prepared by the Technical Committee CENELEC TC 81X, Lightning
protection, was submitted to the formal vote and was approved by CENELEC as EN 62561-4 on 2011-02-21.
This European Standard supersedes EN 50164-4:2008.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-02-21
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-02-21
__________
Endorsement notice
The text of the International Standard IEC 62561-4:2010 was approved by CENELEC as a European
Standard with agreed common modifications as given below.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 62305-1:2006 NOTE  Harmonized as en 62305-1:2006 (not modified).

COMMON MODIFICATIONS

Through the complete document:
Replace all IEC 62305 references by EN 62305.

Replace all IEC 62561 references by EN 62561.

2 Normative references
Replace the first six references to IEC standards with the following:
EN 60068-2-52:1996, Environmental testing – Part 2: Tests – Test Kb: Salt mist, cyclic (sodium chloride
solution) (IEC 60068-2-52:1996)
EN 62305-1, Protection against lightning – Part 1: General principles (IEC 62305-1)
EN 62305-3, Protection against lightning – Part 3: Physical damage to structures and life hazard
(IEC 62305-3)
EN 62305-4, Protection against lightning – Part 4: Electrical and electronic systems within the structure
(IEC 62305-4)
EN ISO 4892-2:2006, Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon-arc lamps
(ISO 4892-2:2006)

---------------------- Page: 4 ----------------------

SIST EN 62561-4:2011
- 3 - EN 62561-4:2011

EN ISO 6988:1994, Metallic and other non-organic coatings – Sulfur dioxide test with general condensation
of moisture (ISO 6988:1985)

Subclause 6.3.1
st
Delete at the end of the 1 paragraph the word “fastening” after “… for screwed…”.

Subclause 6.3.2
st
Delete at the end of the 1 paragraph the word “fastening” after “… for screwed…”.

Sublause 6.3.3
st
Delete at the end of the 1 paragraph the word “fastening” after “… for screwed…”.
rd
Replace the 3 paragraph by the paragraph:
“The specimens are deemed to have passed this part of the test if the conductor or metal parts of the
conductor fastener do not exhibit any corrosive deterioration and if its plastic parts show no sign of
disintegration and no cracks visible to normal or corrected vision.”

Subclause 8.1
st
line of the clause after “…general requirements for type test reports issued by the …”.
Add in the 1
Delete “…test reports.” at the end of the sentence.
Annex A
Clause A.1
Replace “ISO 60068-2-52:1996” by “EN 60068-2-52:1996”.

In the NOTE replace “ISO 60068-2-52:1996” by “EN 60068-2-52:1996”.

Clause A.2
Replace “ISO 6988:1985” by “EN ISO 6988:1994”.
In the NOTE replace “ISO 6988:1985” by “EN ISO 6988:1994”.

Bibliography
Add the following reference:
“EN 60068-2-75:1997, Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
(IEC 60068-2-75:1997)”.

---------------------- Page: 5 ----------------------

SIST EN 62561-4:2011
EN 62561-4:2011 - 4 -
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60068-2-75 1997 Environmental testing - EN 60068-2-75 1997
Part 2-75: Tests - Test Eh: Hammer tests


ISO 4892-3 2006 Plastics - Methods of exposure to laboratory EN ISO 4892-3 2006
light sources -
Part 3: Fluorescent UV lamps


ISO 4892-4 2004 Plastics - Methods of exposure to laboratory - -
light sources -
Part 4: Open-flame carbon-arc lamps


ISO 6957 1988 Copper alloys - Ammonia test for stress - -
corrosion resistance

---------------------- Page: 6 ----------------------

SIST EN 62561-4:2011
IEC 62561-4
®
Edition 1.0 2010-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE


Lightning protection system components (LPSC) –
Part 4: Requirements for conductor fasteners

Composants de système de protection contre la foudre (CSPF) –
Partie 4: Exigences pour les fixations de conducteur

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
S
CODE PRIX
ICS 29.020; 91.120.40 ISBN 978-2-88912-261-5
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 62561-4:2011
– 2 – 62561-4 Ó IEC:2010
CONTENTS
FOREW ORD . 3
INTRODUCTION . 5
1 Sc o pe . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Classification . 7
5 R e q uirements . 7
5.1 Ge n eral . 7
5.2 Environmental requirements . 7
5.3 Mechanical strength . 8
5.4 Installation instructions . 8
5.5 Marking . 8
6 Tests . 8
6.1 General test conditions . 8
6.2 Preparation of the specimen . 9
6.3 Environmental influence test . 9
6.4 Resistance to mechanical effects . 11
6.5 Installation instructions . 14
6.6 Marking test . 15
6.7 Construction . 15
7 Electromagnetic compatibility (EMC) . 15
8 Structure and content of the test report . 15
8.1 General . 15
8.2 Report identification . 16
8.3 Specimen description . 16
8.4 Characterization and condition of the test sample and/or test assembly . 16
8.5 Conductor . 16
8.6 Standards and references . 17
8.7 Test procedure . 17
8.8 Testing equipment, description . 17
8.9 Measuring instruments description . 17
8.10 Results and parameters recorded . 17
Annex A (normative) Environmental test for metallic conductor fasteners . 18
Annex B (normative) Environmental test for non-metallic conductor fasteners –
Resistance to ultraviolet light . 19
Annex C (normative) Flow chart of tests . 20
Bibliography . 21

Figure 1 – Basic arrangement of specimens . 10
Figure 2– Basic arrangement of lateral load test . 12
Figure 3– Typical arrangement for axial movement test . 13
Figure 4 – Impact test apparatus . 14

---------------------- Page: 8 ----------------------

SIST EN 62561-4:2011
62561-4 Ó IEC:2010 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) –

Part 4: Requirements for conductor fasteners


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62561-4 has been prepared by IEC technical committee 81:
Lightning protection.
The text of this standard is based on the following documents:
FDIS Report on voting
81/369/FDIS 81/379/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 62561 series, under the general title Lightning protection
system components (LPSC), can be found on the IEC website.

---------------------- Page: 9 ----------------------

SIST EN 62561-4:2011
– 4 – 62561-4 Ó IEC:2010
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.4

---------------------- Page: 10 ----------------------

SIST EN 62561-4:2011
62561-4 Ó IEC:2010 – 5 –
INTRODUCTION
This Part 4 of IEC 62561 deals with the requirements and tests for conductor fasteners as
being a lightning protection system component (LPSC) designed and implemented according
to the IEC 62305 series of standards.

---------------------- Page: 11 ----------------------

SIST EN 62561-4:2011
– 6 – 62561-4 Ó IEC:2010
LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) –

Part 4: Requirements for conductor fasteners



1 Scope
This Part 4 of IEC 62561 deals with the requirements and tests for metallic and non-metallic
conductor fasteners that are used in conjunction with the air termination, down conductor and
earth termination system.
This standard does not cover the fixing of conductor fasteners to the fabric/membrane/gravel
roofing of structures due to the vast number and types used in modern day construction.
LPSC may also be suitable for use in hazardous atmospheres. Regard should then be taken
of the extra requirements necessary for the components to be installed in such conditions.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60068-2-52:1996, Environmental testing – Part 2-52: Tests – Test Kb: Salt mist, cyclic
(sodium chloride solution)
IEC 60068-2-75:1997, Environmental testing – Part 2: Tests – Test Eh: Hammer tests
IEC 62305 (all parts), Protection against lightning
IEC 62305-3:2006, Protection against lightning – Part 3: Physical damage to structures and
1
life hazard
ISO 4892-2:2006, Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon
– arc lamps
ISO 4892-3:2006, Plastics – Methods of exposure to laboratory light sources – Part 3:
Fluorescent UV lamps
ISO 4892-4:2004, Plastics – Methods of exposure to laboratory light sources – Part 4: Open-
flame, carbon-arc lamps
ISO 6988:1985, Metallic and other non-organic coatings – Sulphur dioxide test with general
condensation of moisture
ISO 6957:1988, Copper alloys – Ammonia test for stress corrosion resistance
3 Terms and definitions
For the purpose of this document, the following terms and definitions apply.
___________
1
 A second edition is in preparation.

---------------------- Page: 12 ----------------------

SIST EN 62561-4:2011
62561-4 Ó IEC:2010 – 7 –
3.1
conductor fastener
metallic, non-metallic or composite component designed to retain and support the air
termination, down conductor and earth termination system, installed at intervals along the
length of the conductors
4 Classification

Conductor fasteners are classified as follows:
a) According to material
– metallic (e.g. hot dip galvanized steel, copper, aluminium, stainless steel);
– non-metallic (e.g. PVC, plastics);
– composite (combination of metal and plastic);
b) According to fixing arrangement of the conductor within the conductor fastener
– with screws;
– without screws (e.g. clips, springs);
c) According to conductor clamping arrangement
– conductor fasteners that are designed to clamp the conductor;
– conductor fasteners that are designed to clamp but allow axial movement of the conductor.
5 Requirements
5.1 General
The conductor fastener shall carry out its function of clamping the conductor in an acceptable
and safe manner when subjected to mechanical influences, lightning discharge stress and
environmental influences.
Conductor fasteners shall comply with the tests given in Clause 6. The material of the
conductor fastener shall be compatible with the conductor it is fastening and the surface
material onto which it is mounted.
NOTE 1 Certain extreme environmental conditions make the choice of non-metallic conductor fasteners
unsuitable. Specific recommendations should be provided by manufacturers as to their suitability in varying
environments.
NOTE 2 Conductor fasteners should be so designed and constructed that safe handling is ensured, that retention
and support for the conductor is provided, and that in normal use their performance is reliable and without danger
to persons and the surrounding.
5.2 Environmental requirements
5.2.1 Corrosion resistance
Metallic or composite conductor fasteners shall withstand corrosion effects.
Compliance is checked following the manufacturer’s declaration for the classification of the
conductor fastener in accordance with Clause 4 and by test specified in 6.3.2 and 6.3.4.
5.2.2 UV resistance
Non-metallic and composite conductor fasteners shall withstand UV effects.
Compliance is checked following the manufacturer’s declaration for the classification of the
conductor fastener in accordance with Clause 4 and by test specified in 6.3.3 and 6.3.4.

---------------------- Page: 13 ----------------------

SIST EN 62561-4:2011
– 8 – 62561-4 Ó IEC:2010
5.3 Mechanical strength
5.3.1 Perpendicular and axial loads
The design of the conductor fastener shall be such that it carries the perpendicular loads
caused by the weight of the conductor, snow, ice and wind and axial loads caused by the
thermal expansion–contraction of the conductor and its weight.
Compliance is checked following the manufacturer’s declaration for the classification of the
conductor fastener in accordance with Clause 4 and by test specified in 6.4.1 and 6.4.2.
5.3.2 Impact tests
Conductor fasteners shall be so designed and constructed to withstand impact stresses
caused accidentally.
Compliance is checked by test specified in 6.4.3.
5.4 Installation instructions
The manufacturer or supplier of the conductor fastener shall provide adequate information in
his literature to ensure that the installer can select and install the component in a suitable and
safe manner, in accordance with IEC 62305-3.
Compliance is checked by inspection in accordance with 6.5.
5.5 Marking
Each conductor fastener shall be marked with
– the manufacturer’s or responsible vendor’s name or logo or trademark,
– product identification or type.
Where it is not possible to make these marks directly onto the product, they shall be made on
the smallest supplied packaging.
NOTE Marking may be applied for example by moulding, pressing, engraving, printing adhesive labels or water
slide transfers.
Compliance is checked in accordance with 6.6.
6 Tests
6.1 General test conditions
Tests specified in this standard are type tests. These tests are of such a nature that, after
they have been performed, they need not be repeated unless changes are made to the
materials, design or type of manufacturing process, which might change the performance
characteristics.
The standard cannot cover all possible types of conductor fasteners and the way of fixing
them on various surfaces of different materials. When required, for these applications,
agreement should be obtained between the test engineer and manufacturer on the specific
testing regime.
Unless otherwise specified, tests are carried out with the specimens assembled and installed
as in normal use specified in the manufacturer's or supplier's instructions, with the
recommended conductor materials, sizes and the tightening torques.

---------------------- Page: 14 ----------------------

SIST EN 62561-4:2011
62561-4 Ó IEC:2010 – 9 –
The tests shall be carried out in the sequence given after environmental tests of the specimen
in accordance with 6.3.
Unless otherwise specified, 12 metallic or 18 composite/non metallic specimens are subjected
to the tests and the requirements are satisfied if all the tests are met.
If only one of the specimens fails to satisfy a test due to a manufacturing fault, that test and
any preceding one which may have influenced the results of the test shall be repeated and
also the tests which follow shall be made in the same required sequence on another full set of
samples, all of which shall comply with the requirements.
Tests for non-metallic conductor fasteners shall not commence earlier than 168 h from the
time of their manufacturing.
A torque meter shall be used for all tightening operations. It shall have a resolution of at least
0,5 Nm and an accuracy of ± 4 % or less.
The applicable tolerance for any applied mechanical load shall be within ± 5 %.
NOTE The applicant, when submitting the first set of samples, may also submit an additional set of samples that
may be necessary should one sample fail. The testing laboratory shall then, without further request, test the
additional set of samples, and shall only reject if a further failure occurs. If the additional set of samples is not
submitted at the same time, a failure of one sample shall entail rejection.
6.2 Preparation of the specimen
If not otherwise specified by the manufacturer, the conductors and specimens shall be
cleaned by using a suitable degreasing agent followed by cleaning in demineralized water and
drying. They shall then be assembled in accordance with the manufacturer’s installation
instructions, e.g. with the recommended conductors and the tightening torques.
The tightening torque should be applied in a steady and uniform manner.
Any conductor fastener accommodating conductors with differences in size (diameter,
thickness and width) equal to or less than 2 mm shall be tested using the minimum conductor
size recommended. If the range is greater than 2 mm, the conductor fastener shall be tested
using the minimum and maximum of conductor sizes.
6.3 Environmental influence test
6.3.1 General
In order that a conductor fastener meets the requirements of this standard, environmental
tests shall be carried out according to Annex A and/or Annex B.
The selection of the tests to be performed depends upon the conductor fastener material.
Annex C provides a flow chart relating the tests identified in 6.3.2, 6.3.3 and 6.3.4 to the
conductor fastener material.
NOTE The sequence of performing the UV test prior to the salt mist test for composite fasteners is because
during the salt mist test the specimen is covered by a salt layer. This would inhibit the UV exposure test.
6.3.2 Metallic
Two sets, each one consisting of three arrangements, shall be assembled and mounted rigidly
on an insulating plate (e.g. brick, Teflon) as shown in Figure 1 in accordance with the
manufacturer’s installation instructions, e.g. with the recommended conductors and the
tightening torques for screwed fastening conductor fasteners.

---------------------- Page: 15 ----------------------

SIST EN 62561-4:2011
– 10 – 62561-4 Ó IEC:2010
The arrangements of specimens shall be subjected to environmental influence tests
consisting of a salt mist test as specified in Clause A.1 followed by a humid sulphurous
atmosphere test as specified in Clause A.2. An additional test by an ammonia atmosphere as
specified in Clause A.3, shall be carried out for conductor fasteners made of copper alloys
with copper content of less than 80 %. This is also valid for conductor fasteners having parts
made of copper alloys with copper content of less than 80 %.
The specimens are deemed to have passed the tests if there are no signs of corrosive
deterioration of the conductor or conductor fastener visible to normal or corrected vision.
NOTE White rust is not considered as corrosive deterioration.
Dimensions in millimetres


33
22
11
22
IEC  2591/10


Key
1 mounting plate
2 fastener
3 conductor

Figure 1 – Basic arrangement of specimens
6.3.3 Non-metallic
Three sets, each one consisting of three arrangements, shall be assembled and mounted
rigidly on an insulating plate (e.g. brick, Teflon) as shown in Figure 1 in accordance with the
manufacturer’s installation instructions, e.g. with the recommended conductors and the
tightening torques for screwed fastening conductor fasteners.
The arrangements of specimens shall be
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.