Preparation of steel substrates before application of paints and related products - Surface roughness characteristics of blast-cleaned steel substrates - Part 4: Method for the calibration of ISO surface profile comparators and for the determination of surface profile - Stylus instrument procedure (ISO 8503-4:2012)

ISO 8503-4:2012 specifies the stylus instrument and describes the procedure for calibrating ISO surface profile comparators conforming to the requirements of ISO 8503-1.
It is also applicable to the determination of the surface profile, within the range 20 μm to 200 μm, of essentially planar blast-cleaned steel. The determination can be carried out on a representative section of the blast-cleaned surface or, if direct observation of the surface is not feasible, on a replica of the surface.

Vorbereitung von Stahloberflächen vor dem Auftragen von Beschichtungsstoffen - Rauheitskenngrößen von gestrahlten Stahloberflächen - Teil 4: Verfahren zur Kalibrierung von ISO-Rauheitsvergleichsmustern und zur Bestimmung der Rauheit - Tastschnittverfahren (ISO 8503-4:2012)

Dieser Teil von ISO 8503 beschreibt das Tastschnittgerät und das Verfahren zur Kalibrierung von ISO Rauheitsvergleichsmustern, welche den Anforderungen nach ISO 8503-1 entsprechen.
Dieser Teil von ISO 8503 ist auch für die Bestimmung des Mittelwertes der mittleren maximalen Rautiefe (durch Tastschnitt)   im Bereich von 20 μm bis 200 μm von im Wesentlichen ebenen gestrahlten Stahl-oberflächen (Bauteilen) anwendbar. Die Bestimmung kann auf einem repräsentativen Teil der gestrahlten Oberfläche oder, wenn dies nicht möglich ist, auf einem Abdruck der Oberfläche durchgeführt werden (siehe Anhang C).
ANMERKUNG   Gegebenenfalls wird mit diesem Verfahren (auch) die Rauheit anderer gestrahlter Oberflächen geprüft.
Ein alternatives Verfahren wird in ISO 8503-3 beschrieben.

Préparation des subjectiles d'acier avant application de peintures et de produits assimilés - Caractéristiques de rugosité des subjectiles d'acier décapés - Partie 4: Méthode pour étalonner les échantillons de comparaison viso-tactile ISO et pour caractériser un profil de surface - Utilisation d'un appareil à palpeur (ISO 8503-4:2012)

L'ISO 8503-4:2012 spécifie l'appareil à palpeur et le mode opératoire pour étalonner les comparateurs viso-tactiles ISO conformes aux exigences de l'ISO 8503-1.
Elle est également applicable à la détermination d'un profil de surface, dans la gamme comprise entre 20 µm et 200 µm, d'acier essentiellement plan décapé par projection d'abrasif. La détermination peut être effectuée sur une partie représentative de la surface préparée ou, si l'observation directe n'est pas possible, sur une réplique de la surface.

Priprava jeklenih podlag pred nanašanjem barvnih in sorodnih premazov - Površinske hrapave značilnosti peskanih jeklenih podlag - 4. del: Metoda za kalibracijo lestvice standardov površinske hrapavosti ISO in za ugotavljanje hrapavosti površine - Postopek z instrumentom Stylus (ISO 8503-4:2012)

Ta del standarda ISO 8503 določa instrument Stylus in opisuje postopek za kalibracijo lestvice standardov površinske hrapavosti ISO, ki je skladna z zahtevami standarda ISO 8503-1. Ta del standarda ISO 8503 se uporablja tudi za ugotavljanje hrapavosti površine (v razponu y5 R od 20 do 200 µm) v osnovi ploščatega peskanega jekla. Ugotavljanje je mogoče izvesti na reprezentativnem delu peskane površine ali, če neposredno opazovanje površine ni izvedljivo, na repliki površine (glejte Dodatek C). Nadomestni postopek je opisan v standardu ISO 8503-3.

General Information

Status
Published
Publication Date
10-Apr-2012
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
23-Mar-2012
Due Date
28-May-2012
Completion Date
11-Apr-2012

Relations

Buy Standard

Standard
EN ISO 8503-4:2012
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 8503-4:2012
01-maj-2012
1DGRPHãþD
SIST EN ISO 8503-4:1997
3ULSUDYDMHNOHQLKSRGODJSUHGQDQDãDQMHPEDUYQLKLQVRURGQLKSUHPD]RY
3RYUãLQVNHKUDSDYH]QDþLOQRVWLSHVNDQLKMHNOHQLKSRGODJGHO0HWRGD]D
NDOLEUDFLMROHVWYLFHVWDQGDUGRYSRYUãLQVNHKUDSDYRVWL,62LQ]DXJRWDYOMDQMH
KUDSDYRVWLSRYUãLQH3RVWRSHN]LQVWUXPHQWRP6W\OXV ,62
Preparation of steel substrates before application of paints and related products -
Surface roughness characteristics of blast-cleaned steel substrates - Part 4: Method for
the calibration of ISO surface profile comparators and for the determination of surface
profile - Stylus instrument procedure (ISO 8503-4:2012)
Vorbereitung von Stahloberflächen vor dem Auftragen von Beschichtungsstoffen -
Rauheitskenngrößen von gestrahlten Stahloberflächen - Teil 4: Verfahren zur
Kalibrierung von ISO-Rauheitsvergleichsmustern und zur Bestimmung der Rauheit -
Tastschnittverfahren (ISO 8503-4:2012)
Préparation des subjectiles d'acier avant application de peintures et de produits
assimilés - Caractéristiques de rugosité des subjectiles d'acier décapés - Partie 4:
Méthode pour étalonner les échantillons de comparaison viso-tactile ISO et pour
caractériser un profil de surface - Utilisation d'un appareil à palpeur (ISO 8503-4:2012)
Ta slovenski standard je istoveten z: EN ISO 8503-4:2012
ICS:
25.220.10 Priprava površine Surface preparation
87.020 Postopki za nanašanje Paint coating processes
barvnih premazov
SIST EN ISO 8503-4:2012 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 8503-4:2012

---------------------- Page: 2 ----------------------

SIST EN ISO 8503-4:2012


EUROPEAN STANDARD
EN ISO 8503-4

NORME EUROPÉENNE

EUROPÄISCHE NORM
February 2012
ICS 25.220.10 Supersedes EN ISO 8503-4:1995
English Version
Preparation of steel substrates before application of paints and
related products - Surface roughness characteristics of blast-
cleaned steel substrates - Part 4: Method for the calibration of
ISO surface profile comparators and for the determination of
surface profile - Stylus instrument procedure (ISO 8503-4:2012)
Préparation des subjectiles d'acier avant application de
Vorbereitung von Stahloberflächen vor dem Auftragen von
peintures et de produits assimilés - Caractéristiques de Beschichtungsstoffen - Rauheitskenngrößen von
rugosité des subjectiles d'acier décapés - Partie 4: Méthode gestrahlten Stahloberflächen - Teil 4: Verfahren zur
d'étalonnage des comparateurs viso-tactiles ISO et de Kalibrierung von ISO-Rauheitsvergleichsmustern und zur
classification d'un profil de surface - Utilisation d'un appareil Bestimmung der Rauheit - Tastschnittverfahren (ISO 8503-
à palpeur (ISO 8503-4:2012) 4:2012)
This European Standard was approved by CEN on 14 February 2012.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2012 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 8503-4:2012: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 8503-4:2012
EN ISO 8503-4:2012 (E)
Contents Page
Foreword .3

2

---------------------- Page: 4 ----------------------

SIST EN ISO 8503-4:2012
EN ISO 8503-4:2012 (E)
Foreword
This document (EN ISO 8503-4:2012) has been prepared by Technical Committee ISO/TC 35 “Paints and
varnishes” in collaboration with Technical Committee CEN/TC 139 “Paints and varnishes” the secretariat of
which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by August 2012, and conflicting national standards shall be withdrawn at
the latest by August 2012.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 8503-4:1995.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 8503-4:2012 has been approved by CEN as a EN ISO 8503-4:2012 without any modification.

3

---------------------- Page: 5 ----------------------

SIST EN ISO 8503-4:2012

---------------------- Page: 6 ----------------------

SIST EN ISO 8503-4:2012
INTERNATIONAL ISO
STANDARD 8503-4
Second edition
2012-02-15
Preparation of steel substrates before
application of paints and related
products — Surface roughness
characteristics of blast-cleaned steel
substrates —
Part 4:
Method for the calibration of ISO
surface profile comparators and for the
determination of surface profile — Stylus
instrument procedure
Préparation des subjectiles d’acier avant application de peintures et
de produits assimilés — Caractéristiques de rugosité des subjectiles
d’acier décapés —
Partie 4: Méthode d’étalonnage des comparateurs viso-tactiles ISO et de
classification d’un profil de surface — Utilisation d’un appareil à palpeur
Reference number
ISO 8503-4:2012(E)
©
ISO 2012

---------------------- Page: 7 ----------------------

SIST EN ISO 8503-4:2012
ISO 8503-4:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved

---------------------- Page: 8 ----------------------

SIST EN ISO 8503-4:2012
ISO 8503-4:2012(E)
Contents Page
Foreword .iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principle . 2
5 Apparatus . 2
6 Test surfaces . 2
6.1 ISO surface profile comparator . 2
6.2 Blast-cleaned steel substrates/replica . 2
7 Procedure for measurement of maximum peak-to-valley height, R . 4
y
8 Calculation and expression of results . 5
9 Test report . 5
Annex A (normative) Test report for the calibration of ISO surface profile comparators and for the
determination of surface profiles . 6
Annex B (normative) Form for recording surface profile measurements made in accordance with
ISO 8503-4 . 7
Annex C (informative) Guidance notes for the preparation and measurement of replicas . 8
Bibliography . 9
© ISO 2012 – All rights reserved iii

---------------------- Page: 9 ----------------------

SIST EN ISO 8503-4:2012
ISO 8503-4:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 8503-4 was prepared by Technical Committee ISO/TC 35, Paints and varnishes, Subcommittee SC 12,
Preparation of steel substrates before application of paints and related products.
This second edition cancels and replaces the first edition (ISO 8503-4:1988), which has been editorially revised
to improve the clarity.
ISO 8503 consists of the following parts, under the general title Preparation of steel substrates before application
of paints and related products — Surface roughness characteristics of blast-cleaned steel substrates:
— Part 1: Specifications and definitions for ISO surface profile comparators for the assessment of abrasive
blast-cleaned surfaces
— Part 2: Method for the grading of surface profile of abrasive blast-cleaned steel — Comparator procedure
— Part 3: Method for the calibration of ISO surface profile comparators and for the determination of surface
profile — Focusing microscope procedure
— Part 4: Method for the calibration of ISO surface profile comparators and for the determination of surface
profile — Stylus instrument procedure
— Part 5: Replica tape method for the determination of the surface profile
iv © ISO 2012 – All rights reserved

---------------------- Page: 10 ----------------------

SIST EN ISO 8503-4:2012
ISO 8503-4:2012(E)
Introduction
The performance of protective coatings of paint and related products applied to steel is significantly affected
by the state of the steel surface immediately prior to painting. The principal factors that are known to influence
this performance are:
a) the presence of rust and mill scale;
b) the presence of surface contaminants, including salts, dust, oils and greases;
c) the surface profile.
International Standards ISO 8501 (all parts), ISO 8502 (all parts) and ISO 8503 (all parts) have been prepared
to provide methods of assessing these factors, while ISO 8504 (all parts) provides guidance on the preparation
methods which are available for cleaning steel substrates, indicating the capabilities of each in attaining
specified levels of cleanliness.
These International Standards do not contain provisions for the protective coating systems to be applied to the
steel surface or for the surface quality provisions for specific situations, even though surface quality can have
a direct influence on the choice of protective coating to be applied and on its performance. Such provisions are
found in other documents, such as national standards and codes of practice.
It is necessary for the users of these International Standards to ensure that the qualities specified are:
— compatible and appropriate both for the environmental conditions to which the steel is exposed and for the
protective coating system to be used;
— within the capability of the cleaning procedure specified.
The four International Standards referred to above deal with the following aspects of preparation of steel substrates:
— ISO 8501: Visual assessment of surface cleanliness;
— ISO 8502: Tests for the assessment of surface cleanliness;
— ISO 8503: Surface roughness characteristics of blast-cleaned steel substrates;
— ISO 8504: Surface preparation methods.