Signalling Protocols and Switching (SPS) - V interfaces at the digital Local Exchange (LE); V5.1 interface for the support of Access Network (AN); Part 2: Protocol Implementation Conformance Statement (PICS) proforma

PICS pro forma for the V5.1 interface specification

Signalizacijski protokoli in komutacija (SPS) - Vmesniki "V" pri digitalnih krajevnih centralah (LE) - Vmesnik V5.1 za podporo dostopovnega omrežja (AN) - 2. del: Proformna izjava o skladnosti izvedbe protokola (PICS)

General Information

Status
Published
Publication Date
31-Oct-1997
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Nov-1997
Due Date
01-Nov-1997
Completion Date
01-Nov-1997

Buy Standard

Standard
ETS 300 324-2:1997
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ETS 300 324-2:1997
01-november-1997
Signalizacijski protokoli in komutacija (SPS) - Vmesniki "V" pri digitalnih krajevnih
centralah (LE) - Vmesnik V5.1 za podporo dostopovnega omrežja (AN) - 2. del:
Proformna izjava o skladnosti izvedbe protokola (PICS)
Signalling Protocols and Switching (SPS) - V interfaces at the digital Local Exchange
(LE); V5.1 interface for the support of Access Network (AN); Part 2: Protocol
Implementation Conformance Statement (PICS) proforma
Ta slovenski standard je istoveten z: ETS 300 324-2 Edition 1
ICS:
33.040.30 Komutacijski in signalizacijski Switching and signalling
sistem systems
SIST ETS 300 324-2:1997 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ETS 300 324-2:1997

---------------------- Page: 2 ----------------------

SIST ETS 300 324-2:1997
EUROPEAN ETS 300 324-2
TELECOMMUNICATION February 1994
STANDARD
Source: ETSI TC-SPS Reference: DE/SPS-03003.5
ICS: 33.080
V interface, V5 interface, LE, AN, PICS
Key words:
Signalling Protocols and Switching (SPS);
V interfaces at the digital Local Exchange (LE)
V5.1 interface for the support of Access Network (AN)
Part 2: Protocol Implementation Conformance Statement (PICS)
proforma
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1994. All rights reserved.
New presentation - see History box

---------------------- Page: 3 ----------------------

SIST ETS 300 324-2:1997
Page 2
ETS 300 324-2: February 1994
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------

SIST ETS 300 324-2:1997
Page 3
ETS 300 324-2: February 1994
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Definitions.7
4 Abbreviations.8
5 Conformance.8
6 PICS proforma .9
6.1 Identification of the implementation .9
6.1.1 Implementation Under Test (IUT) identification.9
6.1.2 System Under Test (SUT) identification.9
6.1.3 Product supplier .9
6.1.4 Client .10
6.1.5 PICS contact person .10
6.2 PICS/System Conformance Statement (SCS).11
6.3 Identification of the protocol.11
6.4 Global statement of conformance.11
6.5 Local exchange.12
6.5.1 Main features.12
6.5.2 Protocol .13
6.5.2.1 Layer 1.13
6.5.2.2 Layer 2.13
6.5.2.3 Layer 3.13
6.5.2.3.1 PSTN functions.13
6.5.2.3.2 PSTN protocol .14
6.5.2.3.3 Control protocol.14
6.5.2.3.4 Port control protocol.14
6.5.2.3.5 Common control .14
6.5.3 Protocol data units.15
6.5.3.1 PSTN protocol .15
6.5.3.1.1 Messages .15
6.5.3.1.2 Information elements, general .16
6.5.3.1.3 Information elements, pulse type.17
6.5.3.1.4 Information elements, steady signals .18
6.5.3.1.5 Information elements, cause types.19
6.5.3.1.6 Information elements, information
element fields.20
6.5.3.2 Control protocol .20
6.5.3.2.1 Messages .20
6.5.3.2.2 Information elements, general .20
6.5.3.2.3 Information elements, port control .21
6.5.3.2.4 Information elements, common
control .22
6.6 Access network.23
6.6.1 Main features.23
6.6.2 Protocol .24
6.6.2.1 Layer 1.24
6.6.2.2 Layer 2.24
6.6.2.3 Layer 3.25
6.6.2.3.1 PSTN protocol .25
6.6.2.3.2 Control protocol.25
6.6.2.3.3 Port control protocol.25

---------------------- Page: 5 ----------------------

SIST ETS 300 324-2:1997
Page 4
ETS 300 324-2: February 1994
6.6.2.3.4 Common control. 25
6.6.3 Protocol data units . 26
6.6.3.1 PSTN protocol. 26
6.6.3.1.1 Messages. 26
6.6.3.1.2 Information elements, general. 27
6.6.3.1.3 Information elements, pulse type . 28
6.6.3.1.4 Information elements, steady signals. 29
6.6.3.1.5 Information elements, cause types . 30
6.6.3.1.6 Information elements, information
element fields . 31
6.6.3.2 Control protocol. 31
6.6.3.2.1 Messages. 31
6.6.3.2.2 Information elements, general. 31
6.6.3.2.3 Information elements, port control . 32
6.6.3.2.4 Information elements, common
control. 33
Annex A (informative): Instructions for completing the PICS proforma. 34
A.1 Identification of the implementation . 34
A.2 Global statement of conformance . 34
A.3 Main features. 34
A.4 Protocol. 34
A.5 Protocol data units. 34
History. 35

---------------------- Page: 6 ----------------------

SIST ETS 300 324-2:1997
Page 5
ETS 300 324-2: February 1994
Foreword
This European Telecommunication Standard (ETS) has been produced by the Signalling Protocols and
Switching (SPS) Technical Committee of the European Telecommunications Standards Institute (ETSI).
This ETS is part 2 of a multi-part standard covering the V5.1 interface specification as described below:
Part 1: V5.1 interface specification;
Part 2: Protocol Implementation Conformance Statement (PICS) proforma;
Part 3: Test Suite Structure and Test Purposes (TSS&TP).
NOTE 1: At the time of publication of this ETS, the final structure of further part(s) and/or
separate ETS(s) containing the test specifications was still under study.
To evaluate conformance of a particular implementation, it is necessary to have a statement of which
capabilities and options have been implemented for a given Open Systems Interconnection (OSI)
protocol. Such a statement is called a Protocol Implementation Conformance Statement (PICS).
NOTE 2: It is however possible to use this ETS to indicate the basic requirements for an Access
Network (AN) or a Local Exchange (LE) required by a network operator. Specific
requirements need to be added, e.g. the Public Switched Telephone Network (PSTN)
port characteristics and conditions.

---------------------- Page: 7 ----------------------

SIST ETS 300 324-2:1997
Page 6
ETS 300 324-2: February 1994
Blank page

---------------------- Page: 8 ----------------------

SIST ETS 300 324-2:1997
Page 7
ETS 300 324-2: February 1994
1 Scope
This second part of ETS 300 324 defines the Protocol Implementation Conformance Statement (PICS)
proforma for the implementation flexibility allowed for a V5.1 interface defined in ETS 300 324-1 [1]. It
allows either the Network Operator to formulate the requirements for V5.1 interface implemented in an
Access Network (AN) or Local Exchange (LE), or to decide whether an implementation meets these
requirements. It details in tabular form the implementation options, i.e. the optional functions additional to
those which are mandatory to implement.
This ETS is in compliance with the relevant requirements and in accordance with the relevant guidance
given in ISO/IEC 9646-7 [3].
2 Normative references
This ETS incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] ETS 300 324-1 (1993): "Signalling Protocols and Switching (SPS);
V interfaces at the digital Local Exchange (LE); V5.1 interface for the
support of Access Network (AN); Part 1: V5.1 interface specification".
[2] ISO/IEC 9646-1: "Information technology - Open systems interconnection -
Conformance testing methodology and framework - Part 1: General
concepts".
[3] ISO/IEC 9646-7: "Information technology - Open systems interconnection -
Conformance testing methodology and framework - Part 7: Implementation
Conformance Statements".
3 Definitions
For the purposes of this ETS, the following definitions apply:
Protocol Implementation Conformance Statement (PICS): a statement made by the supplier of an
Open System Interconnection (OSI) implementation or system, stating which capabilities have been
implemented for a given OSI protocol (see ISO/IEC 9646-1 [2]).
PICS proforma: a document, in the form of a questionnaire, designed by the protocol specifier or
conformance test suite specifier, which when completed for an OSI implementation or system becomes
the PICS (see ISO/IEC 9646-1 [2]).
Static conformance review: a review of the extent to which the static conformance requirements are met
by the Implementation Under Test (IUT), accomplished by comparing the PICS with the static
conformance requirements expressed in the relevant standard(s) (see ISO/IEC 9646-1 [2]).

---------------------- Page: 9 ----------------------

SIST ETS 300 324-2:1997
Page 8
ETS 300 324-2: February 1994
4 Abbreviations
For the purposes of this ETS, the following abbreviations apply:
AN Access Network
AND Boolean "and"
C Conditional requirements (to be observed if the relevant conditions apply)
DTMF Dual Tone Multiple Frequency
ID Identification
IUT Implementation Under Test
LE Local Exchange
M Mandatory requirements (to be observed in all cases)
N/A Not supported, not applicable or the conditions for status are not met
No not supported
NOT Boolean "not"
NT1 Network Termination 1
O Option (may be selected to suit the implementation, provided that any
requirements applicable to the option are observed)
O.n Options, but support required for either at least one or only one of the options in
the group labelled with the same numeral "n"
OR Boolean "or"
OSI Open Systems Interconnection
PICS Protocol Implementation Conformance Statement
PSTN Public Switched Telephone Network
SCS System Conformance Statement
SUT System Under Test
TS Time Slot
Yes Supported
5 Conformance
The supplier of a protocol implementation which is claimed to conform to ETS 300 324-1 [1] is required to
complete a copy of the PICS proforma provided in this ETS and is required to provide the information
necessary to identify both the supplier and the implementation.

---------------------- Page: 10 ----------------------

SIST ETS 300 324-2:1997
Page 9
ETS 300 324-2: February 1994
6 PICS proforma
Notwithstanding the provisions of the copyright Clause related to the text of this ETS, ETSI grants that
users of this ETS may freely reproduce the PICS proforma in this Clause so that it can be used for its
intended purposes and may further publish the completed PICS.
6.1 Identification of the implementation
6.1.1 Implementation Under Test (IUT) identification
IUT name:
IUT version:
6.1.2 System Under Test (SUT) identification
SUT name:
Hardware configuration:
Operating system:
6.1.3 Product supplier
Name:
Address:
Telephone number:

---------------------- Page: 11 ----------------------

SIST ETS 300 324-2:1997
Page 10
ETS 300 324-2: February 1994
Facsimile number:
Additional information:
6.1.4 Client
Name:
Address:
Telephone number:
Facsimile number:
Additional information:
6.1.5 PICS contact person
Name:
Telephone number:
Facsimile number:

---------------------- Page: 12 ----------------------

SIST ETS 300 324-2:1997
Page 11
ETS 300 324-2: February 1994
Additional information:
6.2 PICS/System Conformance Statement (SCS)
Provide the relationship of the PICS with the SCS for the system:
6.3 Identification of the protocol
This PICS proforma applies to the following standard:
ETS 300 324-1 (1994): "Signalling Protocols and Switching (SPS); V interfaces at the digital Local
Exchange (LE); V5.1 interface for the support of Access Network (AN); Part 1: V5.1 interface
specification".
6.4 Global statement of conformance
The implementation described in this PICS meets all the mandatory requirements of the referenced
standard.
[ ] Yes
[ ] No
NOTE: Answering "No" to this question indicates non-conformance to the protocol specification.
Non-supported mandatory capabilities are to be identified in the PICS, with an
explanation of why the implementation is non-conforming.

---------------------- Page: 13 ----------------------

SIST ETS 300 324-2:1997
Page 12
ETS 300 324-2: February 1994
In the tabulations which follow, all references are to ETS 300 324-1 [1].
6.5 Local exchange
6.5.1 Main features
Table 1
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
M1 ISDN ports? O.1 6.1.2 [ ]Yes [ ] No
M2 PSTN ports? O.1 6.1.1 [ ]Yes [ ] No
M3 semipermanent leased lines? O 6.3 [ ]Yes [ ] No
M4 communication channel time slot allocation? M 8.4 [ ]Yes [ ] No
M41 communication path for control functions on TS 16? M 8.4 [ ]Yes [ ] No
M421 communication path for P-type data on TS 16? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M422 communication path for P-type data on TS 15? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M423 communication path for P-type data on TS 31? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M431 communication path for F-type data on TS 16? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M432 communication path for F-type data on TS 15? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M433 communication path for F-type data on TS 31? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M441 communication path for D-channel signalling on TS 16? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M442 communication path for D-channel signalling on TS 15? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M443 communication path for D-channel signalling on TS 31? M1 M 8.4 [ ]Yes [ ] No
NOT M1 N/A
M451 communication path for PSTN signalling on TS 16? M2 M 8.4 [ ]Yes [ ] No
NOT M2 N/A
M452 communication path for PSTN signalling on TS 15? M2 M 8.4 [ ]Yes [ ] No
NOT M2 N/A
M453 communication path for PSTN signalling on TS 31? M1 AND M2 M 8.4 [ ]Yes [ ] No
NOT (M1 AND M2) N/A
M51 allocation of bearer channels to user ports by provisioning? M 7.2.2 [ ]Yes [ ] No
M52 allocation of EFaddr to ISDN user ports by provisioning? M1 M 7.2.2 [ ]Yes [ ] No
NOT M1 N/A
M53 allocation of L3addr to PSTN user ports by provisioning? M2 M 7.2.2 [ ]Yes [ ] No
NOT M2 N/A
M6 envelop function? M 9 [ ]Yes [ ] No
Predicated imaginary features
MX.1 If required by the network operator O
MX.2 If required by the national PSTN protocol O
O.1 = Support of at least one of these items is required

---------------------- Page: 14 ----------------------

SIST ETS 300 324-2:1997
Page 13
ETS 300 324-2: February 1994
6.5.2 Protocol
6.5.2.1 Layer 1
Table 2
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
P1.1 layer 1 balanced? MX.1 M 4 [ ]Yes [ ] No
NOT MX.1 N/A
P1.2 layer 1 coaxial? MX.1 M 4 [ ]Yes [ ] No
NOT MX.1 N/A
P1.3 interface control procedures? M 14.3 [ ]Yes [ ] No
P1.4 detection of loss of signals; 1 ms below 20 dB? O.1 14.3.2 [ ]Yes [ ] No
P1.5 detection of loss of signals; 10 consecutive ZEROs? O.1 14.3.2 [ ]Yes [ ] No
O.1 = Support of at least one of these items is required.
6.5.2.2 Layer 2
Table 3
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
P2.11 frame structure for peer to peer communication? M 9.1 [ ]Yes [ ] No
P2.12 format of fields for data link envelop? M 9.2 [ ]Yes [ ] No
P2.13 envelop address value for control protocol? M 10.3.2.3 [ ]Yes [ ] No
P2.14 envelop address value for PSTN protocol? M2 M 10.3.2.3 [ ]Yes [ ] No
NOT M2 N/A
P2.15 envelop address values for ISDN ports? M1 M 9.2.2.2 [ ]Yes [ ] No
NOT M1 N/A
P2.2 data link sublayer of LAPV5 for control protocol? M 10 [ ]Yes [ ] No
P2.3 data link sublayer of LAPV5 for PSTN protocol? M2 M 10 [ ]Yes [ ] No
NOT M2 N/A
6.5.2.3 Layer 3
6.5.2.3.1 PSTN functions
Table 4
Index Protocol capability Predicate Status Reference Support
Does the implementation support .
P3.11 DTMF senders/receivers? M2 M 13.1.2 [ ]Yes [ ] No
NOT M2 N/A
P3.12 tone generators? M2 M 13.1.2 [ ]Yes [ ] No
NOT M2 N/A
P3.13 announcement? M2 M 13.1.2 [ ]Yes [ ] No
NOT M2 N/A

---------------------- Page: 15 ----------------------

SIST ETS 300 324-2:1997
Page 14
ETS 300 324-2: February 1994
6.5.2.3.2 PSTN protocol
Table 5
Index Protocol capability Predicate Status Reference Support
Does the implementation support .
P3.2 PSTN protocol entity? M2 M 13.2 [ ]Yes [ ] No
NOT M2 N/A
P3.3 PSTN call control entity? M2 M 13.5 - 13.7 [ ]Yes [ ] No
NOT M2 N/A
6.5.2.3.3 Control protocol
Table 6
Index Protocol capability Predicate Status Reference Support
Does the implementation support .
P4.0 Control protocol entity? M 14.4.4 [ ]Yes [ ] No
6.5.2.3.4 Port control protocol
Table 7
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
P4.11 ISDN user port status indication and control? M1 M 14.1 [ ]Yes [ ] No
NOT M1 N/A
P4.12 performance monitoring? M1 AND MX.1 M 14.1.4 [ ]Yes [ ] No
NOT (M1 AND N/A
MX.1)
P4.2 PSTN user port status indication and control? M2 M 14.2 [ ]Yes [ ] No
NOT M2 N/A
6.5.2.3.5 Common control
Table 8
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
P5.1 variant and interface ID control? M 14.5 [ ]Yes [ ] No
P5.2 verify re-provisioning? MX.1 M 14.5 [ ]Yes [ ] No
NOT MX.1 N/A
P5.3 re-provisioning synchronisation? MX.1 M 14.5 [ ]Yes [ ] No
NOT MX.1 N/A

---------------------- Page: 16 ----------------------

SIST ETS 300 324-2:1997
Page 15
ETS 300 324-2: February 1994
6.5.3 Protocol data units
6.5.3.1 PSTN protocol
6.5.3.1.1 Messages
Table 9
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
U1.1 ESTABLISH? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.2 ESTABLISH ACK? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.3 SIGNAL? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.4 SIGNAL ACK? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.5 STATUS? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.6 STATUS ENQUIRY? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.7 DISCONNECT? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.8 DISCONNECT COMPLETE? M2 M 13.3 [ ]Yes [ ] No
NOT M2 N/A
U1.9 PROTOCOL PARAMETER? M2 AND MX.2 M 13.3 [ ]Yes [ ] No
NOT (M2 ANDN/A
MX.2)

---------------------- Page: 17 ----------------------

SIST ETS 300 324-2:1997
Page 16
ETS 300 324-2: February 1994
6.5.3.1.2 Information elements, general
Table 10
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
U1.10 protocol discriminator? M2 M 13.4.2 [ ]Yes [ ] No
NOT M2 N/A
U1.11 layer 3 address? M2 M 13.4.3 [ ]Yes [ ] No
NOT M2 N/A
U1.12 pulse notification? M2 AND MX.2 M 13.4.6.1 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.13 line information? M2 AND MX.2 M 13.4.6.2 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.14 state? M2 M 13.4.6.3 [ ]Yes [ ] No
NOT M2 N/A
U1.15 autonomous signalling sequence? M2 AND MX.2 M 13.4.6.4 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.16 sequence response? M2 AND MX.2 M 13.4.6.5 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.17 sequence-number? M2 M 13.4.7.1 [ ]Yes [ ] No
NOT M2 N/A
U1.18 cadenced-ringing? M2 M 13.4.7.2 [ ]Yes [ ] No
NOT M2 N/A
U1.19 pulsed-signal? M2 M 13.4.7.3 [ ]Yes [ ] No
NOT M2 N/A
U1.20 steady-signal? M2 M 13.4.7.4 [ ]Yes [ ] No
NOT M2 N/A
U1.21 digit-signal M2 M 13.4.7.5 [ ]Yes [ ] No
NOT M2 N/A
U1.22 recognition-time M2 AND MX.2 M 13.4.7.6 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.23 enable-autonomous-acknowledge M2 AND MX.2 M 13.4.7.7 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.24 disable-autonomous-acknowledge M2 AND MX.2 M 13.4.7.8 [ ]Yes [ ] No
NOT (M2 AND N/A
MX.2)
U1.25 cause M2 M 13.4.7.9 [ ]Yes [ ] No
NOT M2 N/A
U1.26 resource-unavailable M2 M 13.4.7.10 [ ]Yes [ ] No
NOT M2 N/A

---------------------- Page: 18 ----------------------

SIST ETS 300 324-2:1997
Page 17
ETS 300 324-2: February 1994
6.5.3.1.3 Information elements, pulse type
Table 11
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
U1.30 pulse type: Pulsed normal polarity? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.31 pulse type: Pulsed reversed polarity? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.32 pulse type: Pulsed battery on c-wire? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.33 pulse type: Pulsed on hook? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.34 pulse type: Pulsed reduced battery ? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.35 pulse type: Pulsed no battery? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.36 pulse type: Initial ring? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.37 pulse type: Meter pulse? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.38 pulse type: 50 Hz pulse? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.39 pulse type: Register recall? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.40 pulse type: Pulsed off hook? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.41 pulse type: Pulsed b-wire connected to earth? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.42 pulse type: Earth loop pulse? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.43 pulse type: Pulsed b-wire connected to battery? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.44 pulse type: Pulsed a-wire connected to earth? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.45 pulse type: Pulsed a-wire connected to battery? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.46 pulse type: Pulsed c-wire connected to earth? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.47 pulse type: Pulsed c-wire disconnected? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.48 pulse type: Pulsed normal battery? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.49 pulse type: Pulsed a-wire disconnected? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.50 pulse type: Pulsed b-wire disconnected? M2 AND MX.2 M 13.4.7.3 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A

---------------------- Page: 19 ----------------------

SIST ETS 300 324-2:1997
Page 18
ETS 300 324-2: February 1994
6.5.3.1.4 Information elements, steady signals
Table 12
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
U1.51 steady signal: Normal polarity? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.52 steady signal: Reversed polarity? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.53 steady signal: Battery on c-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.54 steady signal: No battery on c-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.55 steady signal: Off hook? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.56 steady signal: On hook? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.57 steady signal: Battery on a-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.58 steady signal: A-wire on earth? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.59 steady signal: No battery on a-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.60 steady signal: No battery on b-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.61 steady signal: Reduced battery? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.62 steady signal: No battery? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.63 steady signal: Alternate reduced power/no power? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.64 steady signal: Normal battery? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.65 steady signal: Stop ringing? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.66 steady signal: Start pilot frequency? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.67 steady signal: Stop pilot frequency? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.68 steady signal: Low impedance on b-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.69 steady signal: B-wire connected to earth? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.70 steady signal: B-wire disconnected from earth? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.71 steady signal: Normal battery on b-wire? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.72 steady signal: Low loop impedance? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A

---------------------- Page: 20 ----------------------

SIST ETS 300 324-2:1997
Page 19
ETS 300 324-2: February 1994
Table 12 (concluded)
Index Protocol capability Conditions for Status Reference Support
status
Does the implementation support .
U1.73 steady signal: High loop impedance? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.74 steady signal: Anomalous loop impedance? M2 AND MX.2 M 13.4.7.4 [ ]Yes [ ] No
NOT (M2 AND MX.2) N/A
U1.75 steady signal: A-wire disconnected from e
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.