SIST EN 81-72:2020

Oznaka standarda: SIST EN 81-72:2020
Koda projekta: 00010129
Organizacija: SIST
Naslov (angleški): Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts
Naslov (slovenski): Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne aplikacije za osebna in osebno-tovorna dvigala - 72. del: Dvigala za gasilce
Če kupite standardizacijski dokument v .pdf formatu prek spletne prodaje, vam nudimo 10% popust pri spodnji ceni brez DDV. Cenik SIST
Dokumenti
Ime Jezik Status Cena Dodaj v košarico
SIST EN 81-72:2020 angleški jezik Active SIST-I: 85.91 EUR
PDF
Papir
Tehnični odbor: DTN - Dvigalne in transportne naprave
ICS: 13.220.10 91.140.90
Status: Objavljen
Objavljen: 01-okt-2020
Refer. št. objave: Sporocila 2020-10
Referenčna oznaka: EN 81-72:2020
Področje projekta (angleško): 1.1 This document specifies the additional or deviating requirements to prEN 81 20:2018 for new passenger and goods passenger lifts, which may be used for firefighting and evacuation purposes under firefighters control. 1.2 This document applies, when the following conditions are fulfilled: - the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas; - the building design limits the flow of water into the lift well; - the firefighters lift is not an escape route, such as staircases; - the lift well and the lift environment are fire protected for at least to the same level as the building structure; - the power supply is secure and reliable; - the electrical cable providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; - a suitable maintenance and verification plan is implemented. 1.3 This document does not cover: - the use of lifts with partially enclosed wells for use as firefighters lifts; - lifts installed in new or existing buildings, which are not included in fire resisting building structure; - important modification to existing lifts. 1.4 This document does not define: - the number of firefighters lifts and the floors to be served during firefighting operations; - size of safe area(s); - the use of other than the highest deck of a multi deck lift for firefighting operations. 1.5 This document deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer. 1.6 The following significant hazards are not dealt with in this standard and are assumed to be addressed by the building designer: - not having enough or correctly located firefighters lifts to move the firefighters up the building; - a fire in the firefighters lift well, safe area, machinery space or car; - the absence of building floor identification signs at any floor; - water management is not operating correctly.
Povezava na standarde
Povezava Ime Datum
Nadomešča SIST EN 81-72:2015 - Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne aplikacije za osebna in osebno-tovorna dvigala - 72. del: Dvigala za gasilce 29-jul-2020


• Slovenski standardi SIST s cenovnim razredom AC so popravki standardov in so v večini primerov brezplačni.

• Slovenski standardi SIST s cenovnim razredom AP so privzeti tuji standardi, katerih sestavni del je izvirni standard, ki ga moramo pridobiti pri izdajatelju v tujini. Naročilo pošljite na: prodaja@sist.si.

Najbolje prodajani standardi