Fluorescent induction lamps - Safety specifications

This International Standard specifies the safety requirements for fluorescent induction lamps for general lighting purposes. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure, which can be used to make limited assessment of batches, are also given in this standard. The schematic drawings of the systems are shown in Annex A.

Leuchtstoff-Induktionslampen - Sicherheitsanforderungen

Lampes à fluorescence à induction - Spécifications de sécurité

La CEI 62532:2011 spécifie les exigences de sécurité pour les lampes à fluorescence à induction pour l'éclairage général. Elle spécifie aussi la méthode qu'il convient que le fabricant utilise pour démontrer la conformité de ses produits aux exigences de la présente norme, méthode basée sur l'évaluation de la qualité de la production globale, associée aux résultats d'essais enregistrés sur les produits finis. Cette méthode peut aussi être appliquée à des fins de certification. Des précisions sont également données dans la présente norme sur la procédure de contrôle par lots, qui peut être utilisée pour l'appréciation limitée de la qualité des lots.

Fluorescenčne indukcijske sijalke - Varnostne specifikacije

Ta mednarodni standard opredeljuje varnostne zahteve za fluorescenčne indukcijske sijalke za splošno razsvetljavo. Prav tako določa metodo, ki jo mora uporabiti proizvajalec, da izkaže skladnost z zahtevami tega standarda na podlagi presoje celotne proizvodnje, v povezavi s svojimi zapisi o preskusih končnih izdelkov. Ta metoda se lahko uporablja tudi za certifikacije. Podrobnosti o šaržnem preskusnem postopku, ki se lahko uporablja za omejeno oceno serij, so prav tako podane v tem standardu. Shematske risbe sistemov so prikazane v dodatku A.

General Information

Status
Published
Publication Date
12-Jun-2011
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
08-Jun-2011
Due Date
13-Aug-2011
Completion Date
13-Jun-2011

Relations

Buy Standard

Standard
EN 62532:2011
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62532:2011
01-julij-2011
)OXRUHVFHQþQHLQGXNFLMVNHVLMDONH9DUQRVWQHVSHFLILNDFLMH
Fluorescent induction lamps - Safety specifications
Lampes à fluorescence à induction - Spécifications de sécurité
Ta slovenski standard je istoveten z: EN 62532:2011
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN 62532:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62532:2011

---------------------- Page: 2 ----------------------

SIST EN 62532:2011

EUROPEAN STANDARD
EN 62532

NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM

ICS 29.140.30


English version


Fluorescent induction lamps -
Safety specifications
(IEC 62532:2011)


Lampes à fluorescence à induction -  Leuchtstoff-Induktionslampen -
Spécifications de sécurité Sicherheitsanforderungen
(CEI 62532:2011) (IEC 62532:2011)




This European Standard was approved by CENELEC on 2011-03-07. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62532:2011 E

---------------------- Page: 3 ----------------------

SIST EN 62532:2011
EN 62532:2011 - 2 -
Foreword
The text of document 34A/1422/FDIS, future edition 1 of IEC 62532, prepared by SC 34A, Lamps, of
IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was
approved by CENELEC as EN 62532 on 2011-03-07.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2011-12-07
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2014-03-07
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62532:2011 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60112:2003 NOTE  Harmonized as EN 60112:2003 (not modified).
IEC 60529:1989 NOTE  Harmonized as EN 60529:1991 (not modified).
IEC 60664-1:2007 NOTE  Harmonized as EN 60664-1:2007 (not modified).
IEC 61199:1999 NOTE  Harmonized as EN 61199:1999 (not modified).
IEC 62471:2006 NOTE  Harmonized as EN 62471:2008 (not modified).
__________

---------------------- Page: 4 ----------------------

SIST EN 62532:2011
- 3 - EN 62532:2011
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60061 - Lamp caps and holders together - -
with gauges for the control of
interchangeability and safety


IEC 60360 1998 Standard method of measurement of lamp EN 60360 1998
cap temperature rise


IEC 60598-1 (mod) 2008 Luminaires - EN 60598-1 2008
Part 1: General requirements and tests + A11 2009


IEC 60695-2-10 - Fire hazard testing - EN 60695-2-10 -
Part 2-10: Glowing/hot-wire based test
methods - Glow-wire apparatus and common
test procedure


IEC 60695-2-11 - Fire hazard testing - EN 60695-2-11 -
Part 2-11: Glowing/hot-wire based test
methods - Glow-wire flammability test method
for end-products


IEC 60901 - Single-capped fluorescent lamps - EN 60901 -
Performance specifications


IEC 61347-1 (mod) - Lamp controlgear - EN 61347-1 -
Part 1: General and safety requirements

---------------------- Page: 5 ----------------------

SIST EN 62532:2011

---------------------- Page: 6 ----------------------

SIST EN 62532:2011

IEC 62532
®

Edition 1.0 2011-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside


Fluorescent induction lamps – Safety specifications

Lampes à fluorescence à induction – Spécifications de sécurité

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX T
ICS 29.140.30 ISBN 978-2-88912-352-0

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 62532:2011
– 2 – 62532  IEC:2011
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Safety requirements . 8
4.1 General . 8
4.2 Marking . 8
4.2.1 Marking of the lamps . 8
4.2.2 Requirements . 9
4.3 Requirements for mechanical and electrical connections . 9
4.3.1 Construction and assembly of the lamp . 9
4.3.2 Requirements for electrical connections . 9
4.3.3 Caps and holders . 9
4.4 Insulation resistance . 9
4.4.1 Test method to determine insulation resistance after humidity
treatment . 9
4.4.2 Requirement for the insulation resistance . 10
4.5 Electric strength . 10
4.5.1 Test method to determine the electric strength . 10
4.5.2 Requirement for the electric strength . 10
4.5.3 Compliance . 10
4.6 Parts which can become accidentally live . 10
4.6.1 Metal parts intended to be insulated . 10
4.6.2 Live parts that project from the lamp . 10
4.6.3 Methods to show compliance . 11
4.7 Resistance to heat and fire . 11
4.8 Creepage distances and clearances for lamps . 11
4.9 Temperature rise of the measuring points . 11
4.10 Endurance . 11
4.11 UV radiation . 11
4.12 Information for luminaire design . 11
4.13 Information for ballast design . 11
5 Assessment . 11
Annex A (informative) Schematic drawings of induction lamps . 12
Annex B (informative) Information for luminaire design . 15
Annex C (normative) Schematic drawings for insulation resistance test . 16
Annex D (informative) Information for ballast design . 17
Annex E (normative) Information for thermal test . 19
Annex F (normative) Values and method of measurement of the maximum
temperature rise of the measurement points . 21
Bibliography . 25

---------------------- Page: 8 ----------------------

SIST EN 62532:2011
62532  IEC:2011 – 3 –
Figure A.1 – Schematic drawing of an internal coupled induction lamp (operating
frequency 2 500 kHz to 3 000 kHz) . 12
Figure A.2 – Schematic drawing of an internal coupled induction lamp (operating
frequency 120 kHz to 145 kHz) . 13
Figure A.3 – Schematic drawing of an external coupled induction lamp (operating
frequency 225 kHz to 275 kHz) . 14
Figure C.1 – Test set up for measurement insulation resistance of internal coupled
induction lamp . 16
Figure C.2 – Test set up for measurement of insulation resistance external coupled
induction lamp . 16
Figure F.1 – Temperature test point of internal coupled induction lamp (operating
frequency 2 500 kHz to 3 000 kHz) . 22
Figure F.2 – Temperature test point of internal coupled induction lamp (operating
frequency 120 kHz to 145 kHz) . 23
Figure F.3 – Temperature test points of external coupled induction lamp (operating
frequency 225 kHz to 275 kHz) . 24

Table 1 – Requirements for the electric strength . 10
Table B.1 – Maximum temperature at measurement point(s) under operating condition . 15
Table D.1 – Maximum operating voltage of induction lamps between lamp terminals
and between lamp terminals and ground . 17
Table D.2 – Maximum voltage between lamp terminals . 18
Table E.1 – Heating test temperature levels . 19
Table F.1 – Maximum temperature rise of the lamp temperature test points . 21
Table F.2 – Dimensions of the heat sink of internally coupled induction lamps . 23

---------------------- Page: 9 ----------------------

SIST EN 62532:2011
– 4 – 62532  IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

FLUORESCENT INDUCTION LAMPS –
SAFETY SPECIFICATIONS


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62532 has been prepared by subcommittee 34A: Lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
34A/1422/FDIS 34A/1446/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 10 ----------------------

SIST EN 62532:2011
62532  IEC:2011 – 5 –
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 11 ----------------------

SIST EN 62532:2011
– 6 – 62532  IEC:2011
FLUORESCENT INDUCTION LAMPS –
SAFETY SPECIFICATIONS



1 Scope
This International Standard specifies the safety requirements for fluorescent induction lamps
for general lighting purposes.
It also specifies the method a manufacturer should use to show compliance with the
requirements of this standard on the basis of whole production appraisal in association with
his test records on finished products. This method can also be applied for certification
purposes.
Details of a batch test procedure, which can be used to make limited assessment of batches,
are also given in this standard.
The schematic drawings of the systems are shown in Annex A.
NOTE Self-ballasted induction lamps (where the discharge vessel, the power coupler and the control gear are
integrated in the same product) are excluded from the scope of this standard.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60061, Lamp caps and holders together with gauges for the control of interchangeability
and safety
IEC 60360:1998, Standard method of measurement of lamp cap temperature rise
IEC 60598-1:2008, Luminaires – Part 1: General requirements and tests
IEC 60901, Single-capped fluorescent lamps. Performance specifications
IEC 60695-2-10, Fire Hazard testing – Part 2-10: Glowing/hot-wire based test methods –
Glow-wire apparatus and common test procedure
IEC 60695-2-11, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods –
Glow-wire flammability test method for end-products
IEC 61347-1, Lamp control gear – Part 1: General and safety requirements
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
induction lamp
assembly of a low pressure mercury discharge vessel and an inductive power coupler

---------------------- Page: 12 ----------------------

SIST EN 62532:2011
62532  IEC:2011 – 7 –
3.2
discharge vessel (closed containment description)
vessel containing at least a low pressure mercury vapour, which will be energized by means
of the inductive coupler
NOTE 1 The ultra violet radiation from the resulting discharge is converted by a layer of fluorescent material into
visible light.
NOTE 2 The discharge vessel may have means of mechanical fixation to position it to the inductive power
coupler.
3.3
inductive power coupler
component to transform high frequency electrical energy, by means of induction, in order to
energize the low pressure mercury in the discharge vessel
NOTE 1 The component includes electrical connection.
NOTE 2 The inductive power coupler can contain a means to fixate and position the discharge vessel.
3.4
mechanical interface
means to fixate and position the induction lamp
3.5
internally coupled induction lamp
induction lamp where the coupler is partly surrounded by the discharge vessel
3.6
externally coupled induction lamp
induction lamp where the discharge vessel is partly surrounded by the coupler
3.7
group
lamps having the same electrical characteristics and physical dimensions
3.8
type
lamps of the same group having the same photometric and colour characteristics
3.9
family
lamp groups which have common features of materials, components, and/or method of
processing
3.10
nominal wattage
wattage used to designate the lamp
3.11
working voltage
highest RMS voltage which may occur across any insulation at rated supply voltage,
transients being neglected, in open-circuit conditions or during normal operation
3.12
equilibrium temperature
steady-state temperature of a lamp reached after a sufficient operating time

---------------------- Page: 13 ----------------------

SIST EN 62532:2011
– 8 – 62532  IEC:2011
3.13
design test
test made on a sample for the purpose of checking compliance of the design of a family,
group or a number of groups with the requirements of the relevant clause
3.14
periodic test
test, or series of tests, repeated at intervals in order to check that a product does not deviate
in certain respects from the given design
3.15
running test
test repeated at frequent intervals to provide data for assessment
3.16
batch
all lamps of one family and/or group and identified as such and put forward at one time for
test or checking compliance
3.17
whole production
production during a period of twelve months of all types of lamps within the scope of this
standard and nominated in a list of the manufacturer for inclusion in the certificate
4 Safety requirements
4.1 General
In this document, the term “lamp” stands for “induction lamp”.
Lamps shall be so designed and constructed that in normal use they present no danger to the
user or the surroundings if operated with a ballast complying with IEC 61347-1.
In general, compliance is checked by carrying out all the tests specified.
All plastic materials shall meet all safety requirements of this standard after exposure to UV
and temperature over the claimed lifetime of the lamp. Any accelerated test shall correspond
to the real lifetime effect. The allowed temperature range for the use of the lamp as given by
the lamp manufacturer or responsible vendor shall be noticed.
Plastic material which is directly exposed to UV by the lamp shall be tested at a wavelength of
254 nm. UV irradiance, temperature and testing time are under consideration.
Schematic drawings of the construction of internally and externally coupled induction lamps
are given in Annex A.
4.2 Marking
4.2.1 Marking of the lamps
The following information shall be legibly and durably marked on the lamps:
a) mark of origin (this may take the form of a trade mark, the manufacturer's name or the
name of the responsible vendor);
b) the nominal wattage (marked "W" or "watts") or any other indication which identifies the
lamp.

---------------------- Page: 14 ----------------------

SIST EN 62532:2011
62532  IEC:2011 – 9 –
4.2.2 Requirements
Compliance is checked by the following:
a) presence and legibility of the marking by visual inspection;
b) durability of marking by applying the following test on unused lamps.
The area of the marking on the lamp shall be rubbed by hand with a smooth cloth damped
with water for a period of 15 s.
After this test, the marking shall still be legible.
4.3 Requirements for mechanical and electrical connections
4.3.1 Construction and assembly of the lamp
The construction shall be such that the whole assembly remains safe during and after
operation.
Wiring and cables shall be so situated or protected that they cannot be damaged by sharp
edges, rivets, screws and similar components. Wiring and cables shall not be twisted through
an angle exceeding 360°.
Compliance is checked by visual inspection.
Minimum bending radius, as specified in the manufacturer’s documentation, of the applied
cables and wiring should be observed.
Compliance is checked by measurement of the radii.
4.3.2 Requirements for electrical connections
Electrical connections shall have adequate electrical performance and mechanical strength.
Compliance is checked by carrying out the same kind of tests as given in section 15 of
IEC 60598-1.
4.3.3 Caps and holders
If applicable, the requirements of IEC 60061 apply.
4.4 Insulation resistance
4.4.1 Test method to determine insulation resistance after humidity treatment
Wrap a copper foil around the lamp and connect it to metal parts if any. For schematic
drawing, see Annex c. The lamp shall be conditioned for 48 h in a cabinet containing air with
a relative humidity between 91 % and 95 %. The temperature of the air, t, is maintained within
1 °C of any convenient value between 20 °C and 30 °C.
Before being placed in the humidity cabinet, the lamp wrapped with copper foil is brought to a
temperature between t and (t + 4) °C.
Before the insulation test, visible drops of water, if any, are removed by means of blotting
paper.
Immediately after the moisture treatment, the insulation resistance shall be measured with a
d.c. voltage of 500 V, 1 min after application of the voltage.

---------------------- Page: 15 ----------------------

SIST EN 62532:2011
– 10 – 62532  IEC:2011
4.4.2 Requirement for the insulation resistance
The insulation resistance between the foil and all lamp connections connected together shall
not be less than 2 MΩ.
4.5 Electric strength
4.5.1 Test method to determine the electric strength
Immediately after the insulation resistance test, the same parts as those referred to in 4.4
shall withstand the test voltage of 4.5.2.
The high-voltage transformer used for the test shall be so designed that when the output
terminals are short-circuited after the output voltage has been adjusted to the appropriate test
voltage, the output current is at least 200 mA.
The overcurrent relay shall not trip when the output current is less than 100 mA.
The r.m.s. value of the test voltage applied shall be measured to within ±3 %.
The metal foil referred to in 4.4 shall be placed so that no flashover occurs at the edges of the
insulation.
4.5.2 Requirement for the electric strength
Compliance is checked with a test voltage of substantially sine-wave form, see Table 1, with a
frequency of 50 Hz or 60 Hz and applied for 1 min. Initially, not more than half the prescribed
voltage shall be applied; it shall then be raised rapidly to the full value. The working voltage
shall be given in the manufacturer’s documentation.
Table 1 – Requirements for the electric strength
Test voltage
Working voltage U
V
Up to and including 42 V 500
Above 42 V up to and including 1 000 V 2U + 1 000

4.5.3 Compliance
No flashover or breakdown shall occur during the test.
Glow discharges without a drop in voltage are neglected.
4.6 Parts which can become accidentally live
4.6.1 Metal parts intended to be insulated
Metal parts, if any, intended to be insulated from live parts shall not be or become live.
4.6.2 Live parts that project from the lamp
With the exception of the electrical connection, no live part shall project from any part of the
lamp.

---------------------- Page: 16 ----------------------

SIST EN 62532:2011
62532  IEC:2011 – 11 –
4.6.3 Methods to show compliance
Compliance is checked by a suitable measuring system, which may include visual inspection
where appropriate. It shall be safeguarded that during assembly damage to insulation cannot
occur.
4.7 Resistance to heat and fire
The lamp shall be sufficiently resistant to heat.
Compliance is checked by the test in Annex E.
4.8 Creepage distances and clearances for lamps
The same requirements apply as in section 11 of IEC 60598-1.
4.9 Temperature rise of the measuring points
The values and measurement methods of the maximum temperature rises of the measuring
points are given in Annex F.
4.10 Endurance
Under consideration.
4.11 UV radiation
The specific effective radiant UV power emitted by the lamp shall not exceed the value of
2
2 mW/klm. For reflector lamps, it shall not exceed the value of 2 mW/(m klx).
2
NOTE 1 In IEC 62471, exposure limits are given as effective irradiance values (unit:W/m ) and for risk group
classification, the values for general lighting lamps are
...

Questions, Comments and Discussion