Multi-element metallic cables used in analogue and digital communications and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables

EN 50288-9-1 is a sectional specification for screened cables, characterised from 1 MHz up to 1 000 MHz, to be used in horizontal and building backbone wiring for Information technology generic-cabling systems. This sectional specification contains the electrical, mechanical, transmission and environmental performance characteristics and requirements of the cables when tested in accordance with the referenced test methods. This sectional specification should be read in conjunction with EN 50288-1 which contains the essential provisions for its application. The cables covered in this sectional specification are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains.

Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung - Teil 9-1: Rahmenspezifikation für geschirmte Kabel bis 1 000 MHz - Kabel für den Horizontal- und Steigbereich

Câbles métalliques à éléments multiples utilisés pour les transmissions et les commandes analogiques et numériques - Partie 9-1: Spécification intermédiaire pour câbles écrantés pour applications jusqu'à 1 000 MHz - Câbles horizontaux et verticaux de bâtiment

Večelementni kovinski kabli za analogne in digitalne komunikacije in krmiljenje - 9-1. del: Področna specifikacija za zaslonjene kable s karakteristikami do 1000 MHz - Vodoravni (etažni) in stavbni hrbtenični (medetažni) kabli

Standard EN 50288-9-1 je področna specifikacija za zaslonjene kable, ki se lahko uporabljajo za pasovne širine od 1 MHz do 1000 MHz v vodoravnem (etažnem) in stavbnem hrbteničnem (medetažnem) ožičenju za splošne sisteme okablenja v informacijski tehnologiji. Ta področna specifikacija vsebuje električne, mehanske, prenosne in okoljske karakteristike delovanja ter zahteve za kable pri preskušanju v skladu z navedenimi preskusnimi metodami. Ta področna specifikacija se uporablja skupaj s standardom EN 50288-1, ki vsebuje bistvene določbe za njeno uporabo. Kabli, zajeti v tej področni specifikaciji, so namenjeni za delovanje pri napetostih in tokovih, ki so običajni v komunikacijskih sistemih. Ti kabli niso namenjeni za uporabo z viri z nizko impedanco, na primer z električnim napajanjem javnih omrežij.

General Information

Status
Published
Public Enquiry End Date
24-Jun-2010
Publication Date
20-Jan-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
08-Jan-2013
Due Date
15-Mar-2013
Completion Date
21-Jan-2013

Buy Standard

Standard
EN 50288-9-1:2013
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung - Teil 9-1: Rahmenspezifikation für geschirmte Kabel bis 1 000 MHz - Kabel für den Horizontal- und SteigbereichCâbles métalliques à éléments multiples utilisés pour les transmissions et les commandes analogiques et numériques - Partie 9-1: Spécification intermédiaire pour câbles écrantés pour applications jusqu'à 1 000 MHz - Câbles horizontaux et verticaux de bâtimentMulti-element metallic cables used in analogue and digital communications and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables33.120.20Wires and symmetrical cablesICS:Ta slovenski standard je istoveten z:EN 50288-9-1:2012SIST EN 50288-9-1:2013en01-marec-2013SIST EN 50288-9-1:2013SLOVENSKI
STANDARD



SIST EN 50288-9-1:2013



EUROPEAN STANDARD EN 50288-9-1 NORME EUROPÉENNE
EUROPÄISCHE NORM December 2012
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2012 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50288-9-1:2012 E
ICS 33.120.10
English version
Multi-element metallic cables used in analogue and digital communication and control -
Part 9-1: Sectional specification for screened cables characterised
up to 1 000 MHz -
Horizontal and building backbone cables
Câbles métalliques à éléments multiples utilisés pour les transmissions et les commandes analogiques et numériques -
Partie 9-1: Spécification intermédiaire pour câbles écrantés pour applications jusqu'à 1 000 MHz -
Câbles horizontaux et verticaux de bâtiment
Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung -
Teil 9-1: Rahmenspezifikation für geschirmte Kabel bis 1 000 MHz -
Kabel für den Horizontal- und Steigbereich
This European Standard was approved by CENELEC on 2012-11-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 50288-9-1:2013



EN 50288-9-1:2012 - 2 -
Contents Foreword . 3 1 Scope . 5 2 Normative references . 5 3 Terms, definitions, symbols and abbreviations . 6 3.1 Terms and definitions . 6 3.2 Symbols and abbreviations . 6 4 Cable construction . 6 4.1 Conductor . 6 4.2 Insulation . 6 4.3 Cabling elements . 6 4.4 Identification of cabling elements . 6 4.5 Screening of cabling elements . 6 4.6 Cable make-up . 6 4.7 Filling compound . 6 4.8 Interstitial fillers . 7 4.9 Screening of the cable core . 7 4.10 Moisture barriers . 7 4.11 Wrapping layers . 7 4.12 Sheath . 7 5 Test methods and requirements for completed cables . 7 5.1 General . 7 5.2 Electrical tests . 7 5.3 Mechanical tests . 12 5.4 Environmental tests . 13 5.5 Fire performance tests . 13 Annex A (informative)
Maximum voltage, current and temperature rating for cables used for POE applications . 14 Annex B (informative)
Blank Detail Specification . 15 B.1 General . 15 B.2 Document Details . 15 B.3 Generic specification EN 50288-1 . 16
SIST EN 50288-9-1:2013



- 3 - EN 50288-9-1:2012
Foreword This document (EN 50288-9-1:2012) has been prepared by CLC/SC 46XC, "Multicore, multipair and quad data communication cables". The following dates are fixed: • latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-11-12 • latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2015-11-12 This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). EN 50288 series is divided into the following parts: − EN 50288-1, Multi-element metallic cables used in analogue and digital communication and control  Part 1: Generic specification; − EN 50288-2-1, Multi-element metallic cables used in analogue and digital communication and control  Part 2-1: Sectional specification for screened cables characterised up to 100 MHz  Horizontal and building backbone cables; − EN 50288-2-2, Multi-element metallic cables used in analogue and digital communication and control  Part 2-2: Sectional specification for screened cables characterised up to 100 MHz  Work area and patch cord cables; − EN 50288-3-1, Multi-element metallic cables used in analogue and digital communication and control  Part 3-1: Sectional specification for unscreened cables characterised up to 100 MHz  Horizontal and building backbone cables; − EN 50288-3-2, Multi-element metallic cables used in analogue and digital communication and control  Part 3-2: Sectional specification for unscreened cables characterised up to 100 MHz  Work area and patch cord cables; − EN 50288-4-1, Multi-element metallic cables used in analogue and digital communication and control  Part 4-1: Sectional specification for screened cables characterised up to 600 MHz  Horizontal and building backbone cables; − EN 50288-4-2, Multi-element metallic cables used in analogue and digital communication and control  Part 4-2: Sectional specification for screened cables characterised up to 600 MHz  Work area and patch cord cables; − EN 50288-5-1, Multi-element metallic cables used in analogue and digital communication and control  Part 5-1: Sectional specification for screened cables characterized up to 250 MHz  Horizontal and building backbone cables; − EN 50288-5-2, Multi-element metallic cables used in analogue and digital communication and control  Part 5-2: Sectional specification for screened cables characterized up to 250 MHz  Work area and patch cord cables; SIST EN 50288-9-1:2013



EN 50288-9-1:2012 – 4 –
− EN 50288-6-1, Multi-element metallic cables used in analogue and digital communication and control  Part 6-1: Sectional specification for unscreened cables characterised up to 250 MHz  Horizontal and building backbone cables; − EN 50288-6-2, Multi-element metallic cables used in analogue and digital communication and control  Part 6-2: Sectional specification for unscreened cables characterised up to 250 MHz  Work area and patch cord cables; − EN 50288-7, Multi-element metallic cables used in analogue and digital communication and control  Part 7: Sectional specification for instrumentation and control cables; − EN 50288-8, Multi-element metallic cables used in analogue and digital communication and control  Part 8: Specification for type 1 cables characterised up to 2 MHz; − EN 50288-9-1, Multi-element metallic cables used in analogue and digital communications and control  Part 9-1: Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz  Horizontal and building backbone cables (the present document); − EN 50288-10-1, Multi-element metallic cables used in analogue and digital communications and control  Part 10-1: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz  Horizontal and building backbone cables; − EN 50288-11-1, Multi-element metallic cables used in analogue and digital communication and control  Part 11-1: Sectional specification for un-screened cables characterised from 1 MHz up to 500 MHz  Horizontal and building backbone cables. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.
SIST EN 50288-9-1:2013



- 5 - EN 50288-9-1:2012
1 Scope EN 50288-9-1 is a sectional specification for screened cables, characterised
from 1 MHz
up to 1 000 MHz, to be used in horizontal and building backbone wiring for Information technology generic-cabling systems. This sectional specification contains the electrical, mechanical, transmission and environmental performance characteristics and requirements of the cables when tested in accordance with the referenced test methods. This sectional specification should be read in conjunction with EN 50288-1 which contains the essential provisions for its application. The cables covered in this sectional specification are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50288-1 Multi-element metallic cables used in analogue and digital communication and control  Part 1: Generic specification EN 50289-1-4 Communication cables  Specifications for test methods  Part 1-4: Electrical test methods  Insulation resistance EN 50289-3-2 Communication cables  Specifications for test methods  Part 3-2: Mechanical test methods  Tensile strength and elongation for conductor EN 50289-3-4 Communication cables  Specifications for test methods  Part 3-4: Mechanical test methods  Tensile strength, elongation and shrinkage of insulation and sheath EN 50289-3-5 Communication cables  Specifications for test methods  Part 3-5: Mechanical test methods  Crush resistance of the cable EN 50289-3-6 Communication cables  Specifications for test methods  Part 3-6: Mechanical test methods  Impact resistance of the cable EN 50289-3-8 Communication cables  Specifications for test methods  Part 3-8: Mechanical test methods  Abrasion resistance of cable sheath markings EN 50289-3-9:2001 Communication cables  Specifications for test methods  Part 3-9: Mechanical test methods  Bending tests EN 50289-3-16 Communication cables  Specifications for test methods  Part 3-16: Mechanical test methods  Cable tensile performance EN 50289-4-6 Communication cables  Specifications for test methods  Part 4-6: Environmental test methods  Temperature cycling EN 50290-2
(all parts) Communication cables  Part 2: Common design rules and construction EN 60708 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath (IEC 60708) IEC 60189-2 Low-frequency cables and wires with PVC insulation and PVC sheath  Part 2: Cables in pairs, triples, quads and quintuples for inside installations SIST EN 50288-9-1:2013



EN 50288-9-1:2012 – 6 –
3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 50288-1 and the following apply. 3.1.1 screening of cable a cable is considered screened when the cable core is covered by a continuous conductive layer forming part of the shielding and grounding system.
D.C. continuity has to be given and minimum shielding requirements have to be met 3.2 Symbols and abbreviations For the purposes of this document, the following abbreviations apply. EX Exogenous (derived or originating externally) POE Power Over Ethernet 4 Cable construction 4.1 Conductor The conductor shall be solid annealed copper and comply with the requirements of EN 50288-1, 4.1. The nominal conductor diameter shall be ≥ 0,50 mm and ≤ 0,80 mm. NOTE Constructions with ‘copper clad’ conductors do not meet the requirements. 4.2 Insulation The insulation shall be of a suitable material in accordance with the appropriate part of the
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.