Lightning Protection System Components (LPSC) - Part 6: Requirements for lightning strike counters (LSC) (IEC 62561-6:2011, modified)

This Part 6 of IEC 62561 specifies the requirements and tests for devices intended to count the number of lightning strike pulses flowing in a conductor. This conductor may be part of a lightning protection system (LPS) or connected to an SPD installation (or other conductors which are not intended to conduct a significant portion of lightning currents).

Blitzschutzsystembauteile (LPSC) - Teil 6: Anforderungen an Blitzzähler (LSC) (IEC 62561-6:2011, modifiziert)

Composants de système de protection contre la foudre (CSPF) - Partie 6: Exigences pour les compteurs de coups de foudre (LSC) (CEI 62561-6:2011, modifiée)

La CEI 62561-6:2011 spécifie les exigences et les essais à appliquer aux dispositifs destinés à compter le nombre de coups de foudre conduits à travers un conducteur. Ce conducteur peut faire partie d'un système de protection contre la foudre (SPF) ou être relié à une installation de parafoudre (ou d'autres conducteurs qui ne sont pas destinés à conduire une partie significative des courants de foudre).

Zahteve za elemente sistema za zaščito pred strelo (LPSC) - 6. del: Zahteve za števce udarov strele (LSC) (IEC 62561-6:2011, spremenjen)

Ta 6. del IEC 62561 opredeljuje zahteve in preskuse za naprave, namenjene štetju števila udarov strele v prevodniku. Ta prevodnik je lahko del sistema za zaščito pred strelo (LPS) ali povezan z namestitvijo SPD (ali drugimi prevodniki, ki niso namenjeni vodenju velikih delov tokov strele).

General Information

Status
Withdrawn
Publication Date
12-Oct-2011
Withdrawal Date
01-Mar-2021
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
25-Feb-2021
Due Date
20-Mar-2021
Completion Date
02-Mar-2021

Relations

Buy Standard

Standard
EN 62561-6:2011
English language
23 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62561-6:2011
01-november-2011
1DGRPHãþD
SIST EN 50164-6:2009
=DKWHYH]DHOHPHQWHVLVWHPD]D]DãþLWRSUHGVWUHOR /36& GHO=DKWHYH]D
ãWHYFHXGDURYVWUHOH /6&  ,(&VSUHPHQMHQ
Lightning Protection System Components (LPSC) - Part 6: Requirements for lightning
strike counters (LSC) (IEC 62561-6:2011, modified)
Blitzschutzsystembauteile (LPSC) - Teil 6: Anforderungen an Blitzzähler (LSC) (IEC
62561-6:2011, modifiziert)
Composants de système de protection contre la foudre (CSPF) - Partie 6: Exigences
pour les compteurs de coups de foudre (LSC) (CEI 62561-6:2011, modifiée)
Ta slovenski standard je istoveten z: EN 62561-6:2011
ICS:
91.120.40 =DãþLWDSUHGVWUHOR Lightning protection
SIST EN 62561-6:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62561-6:2011

---------------------- Page: 2 ----------------------

SIST EN 62561-6:2011

EUROPEAN STANDARD
EN 62561-6

NORME EUROPÉENNE
September 2011
EUROPÄISCHE NORM

ICS 29.020; 91.120.40 Supersedes EN 50164-6:2009


English version


Lightning protection system components (LPSC) -
Part 6: Requirements for lightning strike counters (LSC)
(IEC 62561-6:2011, modified)


Composants de système de protection Blitzschutzsystembauteile (LPSC) -
contre la foudre (CSPF) - Teil 6: Anforderungen an Blitzzähler (LSC)
Partie 6: Exigences pour les compteurs de (IEC 62561-6:2011, modifiziert)
coups de foudre (LSC)
(CEI 62561-6:2011, modifiée)





This European Standard was approved by CENELEC on 2011-07-28. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62561-6:2011 E

---------------------- Page: 3 ----------------------

SIST EN 62561-6:2011
EN 62561-6:2011 – 2 –
Foreword
The text of document 81/392/FDIS, future edition 1 of IEC 62561-6, prepared by IEC TC 81, Lightning
protection, was submitted to the IEC-CENELEC parallel vote.
A draft amendment, prepared by the Technical Committee CENELEC TC 81X, Lightning protection,
was submitted to the formal vote.
The combined texts were approved by CENELEC as EN 62561-6:2011 on 2011-07-28.
This European Standard supersedes EN 50164-6:2009.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-07-28
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2014-07-28
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62561-6:2011 was approved by CENELEC as a European
Standard with agreed common modifications as given below.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 60068-2-52:1996 NOTE  Harmonized as EN 60068-2-52:1996 (not modified).
IEC 61000-6-2 NOTE  Harmonized as EN 61000-6-2.

COMMON MODIFICATIONS
Whole document
Replace all references to IEC 62305 by references to EN 62305.
Replace all references to IEC 62561 by references to EN 62561.
2 Normative references
Replace this subclause by:
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 60068-2-52:1996, Environmental testing - Part 2: Tests - Test Kb: Salt mist, cyclic (sodium
chloride solution) (IEC 60068-2-52:1996 + corr. July 1996)
EN 60068-2-75:1997, Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
(IEC 60068-2-75:1997)

---------------------- Page: 4 ----------------------

SIST EN 62561-6:2011
– 3 – EN 62561-6:2011
EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 61000-6-4, Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard
for industrial environments (IEC 61000-6-4)
EN 61180-1, High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and
procedure requirements (IEC 61180-1)
EN 62305 (series), Protection against lightning (IEC 62305 series)
EN ISO 4892-2:2006, Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc
lamps (ISO 4892-2:2006)
EN ISO 4892-3:2006, Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent
UV lamps (ISO 4892-3:2006)
EN ISO 6988:1994, Metallic and other non-organic coatings - Sulfur dioxide test with general
condensation of moisture (ISO 6988:1985)
ISO 4892-4:2004, Plastics - Methods of exposure to laboratory light sources - Part 4: Open-flame
carbon-arc lamps
ISO 6957:1988, Copper alloys - Ammonia test for stress corrosion resistance
3 Terms and definitions
In 3.5, replace the reference to IEC 60529 by EN 60529.
4.4 Design
In the third paragraph, replace the reference to IEC 60529 by EN 60529.
5 Classification
b
In Table 1, footnote , replace the reference to IEC 60060-1 by EN 60060-1.
6 Tests
In 6.4, fifth paragraph, replace all the references to IEC 60068-2-75:1997 by
EN 60068-2-75:1997.
In 6.5, replace the two references to IEC 60529 by EN 60529.
In 6.6.1, replace the reference to IEC 61180-1 by EN 61180-1.
7 Electromagnetic compatibility (EMC)
In 7.1, replace the reference to IEC 61000-6-4 by EN 61000-6-4.

In 7.2, replace the reference to IEC 61000-6-4 by EN 61000-6-4.
8 Structure and content of the test report
8.1 General
In the first sentence, replace “for laboratory test reports” by "for type test reports issued by the
laboratory".

---------------------- Page: 5 ----------------------

SIST EN 62561-6:2011
EN 62561-6:2011 – 4 –
Annex A (normative) Resistance to ultraviolet light
In A.2, replace the reference to ISO 4892-2:2006 by EN ISO 4892-2:2006.

In A.4, replace the reference to ISO 4892-3:2006 by EN ISO 4892-3:2006.

Annex B (normative) Conditioning/ageing for lightning strike counters
In Clause B.1, replace twice “IEC 60068-2-52:1996” by “EN 60068-2-52:1996”.
In Clause B.2, replace twice “ISO 6988:1985” by “EN ISO 6988:1994”.
Bibliography
In the second paragraph, replace the reference IEC 60068-2-52:1996 by
EN 60068-2-52:1996.

In the third paragraph, replace the reference IEC 61000-6-2 by EN 61000-6-2.
Add the following:
EN 60060-1, High-voltage test techniques - Part 1: General definitions and test requirements
(IEC 60060-1)

---------------------- Page: 6 ----------------------

SIST EN 62561-6:2011
– 5 – EN 62561-6:2011
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications


The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60060-1 - High-voltage test techniques - EN 60060-1 -
Part 1: General definitions and test
requirements


IEC 60068-2-52 1996 Environmental testing - EN 60068-2-52 1996
+ corr. July 1996 Part 2: Tests - Test Kb: Salt mist, cyclic
(sodium chloride solution)


IEC 60068-2-75 1997 Environmental testing - EN 60068-2-75 1997
Part 2-75: Tests - Test Eh: Hammer tests


IEC 60529 - Degrees of protection provided by EN 60529 -
enclosures (IP Code)


IEC 61000-6-4 - Electromagnetic compatibility (EMC) - EN 61000-6-4 -
Part 6-4: Generic standards - Emission
standard for industrial environments


IEC 61180-1 - High-voltage test techniques for low-voltage EN 61180-1 -
equipment -
Part 1: Definitions, test and procedure
requirements


IEC 62305 Series Protection against lightning - EN 62305 Series
Part 1: General principles


ISO 4892-2 2006 Plastics - Methods of exposure to laboratory EN ISO 4892-2 2006
light sources -
Part 2: Xenon-arc lamps


ISO 4892-3 2006 Plastics - Methods of exposure to laboratory EN ISO 4892-3 2006
light sources -
Part 3: Fluorescent UV lamps


ISO 4892-4 2004 Plastics - Methods of exposure to laboratory - -
light sources -
Part 4: Open-flame carbon-arc lamps


ISO 6957 1988 Copper alloys - Ammonia test for stress - -
corrosion resistance


ISO 6988 1985 Metallic and other non-organic coatings - EN ISO 6988 1994
Sulfur dioxide test with general condensation
of moisture

---------------------- Page: 7 ----------------------

SIST EN 62561-6:2011

---------------------- Page: 8 ----------------------

SIST EN 62561-6:2011
IEC 62561-6
®

Edition 1.0 2011-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE


Lightning protection system components (LPSC) –
Part 6: Requirements for lightning strike counters (LSC)

Composants de système de protection contre la foudre (CSPF) –
Partie 6: Exigences pour les compteurs de coups de foudre (LSC)

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX R
ICS 29.020; 91.120.40 ISBN 978-2-88912-557-9

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 9 ----------------------

SIST EN 62561-6:2011
– 2 – 62561-6 © IEC:2011
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references. 6
3 Terms and definitions . 7
4 Requirements . 7
4.1 General . 7
4.2 Documentation . 7
4.3 Marking . 8
4.4 Design . 8
5 Classification . 8
6 Tests . 9
6.1 General test conditions . 9
6.2 Resistance to UV radiation tests . 10
6.3 Resistance tests to corrosion (for metallic parts) . 10
6.4 Mechanical tests . 10
6.5 Index of protection confirmation (IP Code) . 12
6.6 Electrical tests . 12
6.6.1 General conditions for test . 12
6.6.2 Minimum threshold current (I ) . 12
tc
6.6.3 Checking of non detection with I /2 . 12
tc
6.6.4 Withstand and counting at I current . 12
mcw
6.6.5 Multi pulse test . 12
6.7 Marking test. 12
7 Electromagnetic compatibility (EMC) . 13
7.1 Electromagnetic immunity . 13
7.2 Electromagnetic emission . 13
8 Structure and content of the test report . 13
8.1 General . 13
8.2 Report identification . 13
8.3 Specimen description . 14
8.4 Standards and references . 14
8.5 Test procedure . 14
8.6 Testing equipment description . 14
8.7 Measuring instruments description . 14
8.8 Results and parameters recorded . 14
8.9 Statement of pass/fail . 15
Annex A (normative) Resistance to ultraviolet light . 16
Annex B (normative) Conditioning/ageing for lightning strike counters . 17
Bibliography . 18

Figure 1 – Pendulum hammer test apparatus . 11

Table 1 – Typical values for I and I . 9
tc mcw

---------------------- Page: 10 ----------------------

SIST EN 62561-6:2011
62561-6 © IEC:2011 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) –

Part 6: Requirements for lightning strike counters (LSC)


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all
national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-
operation on all questions concerning standardization in the electrical and electronic fields. To this end and in
addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in
this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also
participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in
accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all interested
IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between any
IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services
carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or other
damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising
out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62561-6 has been prepared by IEC technical committee 81: Lightning
protection.
The text of this standard is based on the following documents:
FDIS Report on voting
81/392/FDIS 81/400/RVD

Full information on the voting for the approval of this standard can be found in the report on voting
indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 62561 series, published under the general title Lightning protection
system components (LPSC), can be found on the IEC website.

---------------------- Page: 11 ----------------------

SIST EN 62561-6:2011
– 4 – 62561-6 © IEC:2011
The committee has decided that the contents of this publication will remain unchanged until the
stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the
specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 12 ----------------------

SIST EN 62561-6:2011
62561-6 © IEC:2011 – 5 –
INTRODUCTION
This Part 6 of IEC 62561 deals with the requirements and tests for lightning protection system
components (LPSC) used for the installation of a lightning protection system (LPS) designed and
implemented according to the IEC 62305 series of standards.

---------------------- Page: 13 ----------------------

SIST EN 62561-6:2011
– 6 – 62561-6 © IEC:2011
LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) –

Part 6: Requirements for lightning strike counters (LSC)



1 Scope
This Part 6 of IEC 62561 specifies the requirements and tests for devices intended to count the
number of lightning strike pulses flowing in a conductor. This conductor may be part of a lightning
protection system (LPS) or connected to an SPD installation (or other conductors which are not
intended to conduct a significant portion of lightning currents).
NOTE Lightning strike counters may also be suitable for use in hazardous atmospheres. Regard should then be taken of
the extra requirements necessary for the components to be installed in such conditions.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.
IEC 60060-1, High-voltage test techniques – Part 1: General definitions and test requirements
IEC 60068-2-52:1996, Environmental testing – Part 2-52: Tests – Test Kb: Salt mist, cyclic (sodium
chloride solution)
IEC 60068-2-75:1997, Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 61000-6-4, Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission
standard for industrial environments
IEC 61180-1, High-voltage test techniques for low-voltage equipment – Part 1: Definitions, test and
procedure requirements
IEC 62305-1:2010, Protection against lightning – Part 1: General principles
ISO 4892-2:2006, Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon-arc
lamps
ISO 4892-3:2006, Plastics – Methods of exposure to laboratory light sources – Part 3: Fluorescent
UV lamps
ISO 4892-4, Plastics – Methods of exposure to laboratory light sources – Part 4: Open-flame
carbon-arc lamps
ISO 6957:1988, Copper alloys – Ammonia test for stress corrosion resistance
ISO 6988:1985, Metallic and other non-organic coatings – Sulfur dioxide test with general
condensation of moisture

---------------------- Page: 14 ----------------------

SIST EN 62561-6:2011
62561-6 © IEC:2011 – 7 –
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
lightning strike counter
device intended to count the number of lightning strikes based on current flowing in a conductor
3.2
threshold current
I
tc
peak value of the discharge current with an 8/20 waveform that the lightning strike counter will
count in 100 % of the cases
3.3
maximum counting discharge current
I
mcw, 8/20
peak value of a current through the conductor having an 8/20 waveform and magnitude according
to the counting and withstand current test
NOTE 8/20 waveform can be used only for lightning strike counters connected to SPDs Type 2.
3.4
maximum withstand discharge current
I
mcw, 10/350
peak value of a current through the conductor having an 10/350 waveform and magnitude
according to the counting and withstand current test
3.5
degree of protection of enclosure
IP
numerical classification according to IEC 60529, preceded by the symbol IP, applied to the
enclosure of electrical apparatus to provide:
– protection of persons against contact with, or approach to, live parts and against contact with
moving parts (other than smooth rotating shafts and the like) inside the enclosure,
– protection of the electrical apparatus against ingress of solid foreign objects, and
– where indicated by the classification, protection of the electrical apparatus against harmful
ingress of water
[IEC 60050:2008, 426-04-02]
4 Requirements
4.1 General
The lightning strike counter shall be designed in such a way that in normal use their performance is
reliable and without danger to persons and the surrounding.
The choice of a material depends on its ability to match the particular application requirements.
4.2 Documentation
The manufacturer or supplier of the lightning strike counter shall provide adequate information in
his literature to ensure that the installer can select and install the counter in a suitable and safe
manner.
Compliance is checked by inspection.

---------------------- Page: 15 ----------------------

SIST EN 62561-6:2011
– 8 – 62561-6 © IEC:2011
4.3 Marking
All products complying with this standard shall be marked at least with the following:
a) the name of the manufacturer or his trademark;
b) the reference of the type or the serial number;
c) the position of the assembly if necessary;
d) the degree of protection (IP) if applicable;
e) conformity to the present standard (of which in particular I and I if applicable).
tc mcw
For small devices, if the place available is not sufficient for all the indications to appear, the
indications cited in a) and b) above shall at least be reproduced on the apparatus and visible once
installed. The indications cited in c), d) and e), can be carried on the packaging and/or in
installation data sheet and/or the catalogue of the manufacturer.
Compliance is checked in accordance with 6.7.
NOTE Marking may be applied, for example, by moulding, pressing, engraving, printing adhesive labels, or water slide
transfers.
4.4 Design
The design of the lightning counter shall be such that it carries out its function of counting the
number of lightning strikes flowing in a conductor.
These devices shall detect and record lightning strikes regardless of the polarity of the discharge
current.
Lightning strike counters intended to be used outdoors shall be able to withstand environmental
conditions including temperature, dust and humidity. The minimum degree of protection is IP 43
obtained by itself or in combination with a box in accordance with IEC 60529.
The manufacturer shall provide the operation environmental conditions such as temperature and
humidity
The threshold current I , the maximum counting discharge current (I ) and the maximum
tc mcw,8/20
discharge withstand current (I ) are declared by the manufacturer. At I /2, the surge
mcw,10/350 tc
lightning strike counter shall not operate. Compliance is checked in accordance with 6.6.2, 6.6.3
and 6.6.4.
The size of display if any, shall allow a normal reading of the number of lightning strikes recorded,
when it is installed in accordance with the instructions of the manufacturer.
The fixing system of the lightning strike counter should not apply an unacceptable stress to the
conductor.
Its material shall be compatible with that of the conductor (galvanic coupling).
5 Classification
Lightning strike counters are classified according to their application, threshold currents and
maximum counting and withstand current.
Application: for connection on LPS conductors, for connection on SPD conductors and for
connection on both conductors.

---------------------- Page: 16 ----------------------

SIST EN 62561-6:2011
62561-6 © IEC:2011 – 9 –
NOTE This standard is applicable to those lightning strike counters that may be mounted in SPD enclosures but may not
be required for those lightning strike counters which are integral to an SPD.
The values I and I should comply with Table 1.
tc mcw
Table 1 – Typical values for I and I
tc mcw
Application Values for I Values for I
tc mcw
Connection on LPS 1 kA 100 kA
– – – – –
b a
conductors 8/20 10/350
Connection on SPD 500 A 20 kA 40 kA 60 kA 80 kA 100 kA

b b b b b b
conductors 8/20 8/20 8/20 8/20 8/20 8/20
Connection on LPS and 1 kA 100 kA
– – – – –
b a
SPD conductors 8/20 10/350
a
The 10/350 impulse is defined by three parameters, a peak current value I , a charge Q and a
peak
specific energy W/R (see IEC 62305-1).
b
The 8/20 impulse is defined according to IEC 60060-1.

6 Tests
6.1 General test conditions
The tests in accordance with this standard are type tests.
Unless otherwise specified, tests are carried out with the specimens assembled and installed as in
normal use according to the manufacturer’s or supplier’s instructions.
All tests are carried out on new specimens.
Unless otherwise specified, three specimens are subjected to the tests and the requirements are
satisfied if all the tests are met. If only one of the specimens does not satisfy a test due to an
assembly or a manufacturing fault, that test and any preceding one which may have influenced the
results of the test shall be repeated and also the tests which follow shall be carried out in the
required sequence on another full set of specimens, all of which shall comply with the
re
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.